When constructed, this kit places an Active Vent on any support structure.
Kit (Active Vent)
____________ General ____________
____________
____________
Paintable
✔
Prefab Hash
-842048328
Prefab Name
ItemActiveVent
______________ Item ______________
____________
____________
Stack Size
5
Class
None
0
SortingClass
Kits
1
____________ Durability ____________
____________
____________
Flashpoint Temperature
1200℃
Autoignition Temperature
8000℃
The active vent is a powered device for maintaining gas pressure by pumping gas into (or out of) a pipe network. The vent has two modes: 'Outward' sets it to pump gas into a space until pressure is reached; 'Inward' sets it to pump gas out until pressure is reached. The pressure parameter can be set on a connected Console . Default pressure is 101kPa for Outward; 0kPa for Inward ...
Active Vent
AV
____________ General ____________
______________
______________
Paintable
✔
Prefab Hash
-1129453144
Prefab Name
StructureActiveVent
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Active Vent)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
100W
100W
Heat Generation
20W
20W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Power And Data
0
Pipe
1
This kit creates a Passive Vent among other variants.
Passive Vent
____________ General ____________
____________
____________
Paintable
✔
Prefab Hash
238631271
Prefab Name
ItemPassiveVent
______________ Item ______________
____________
____________
Stack Size
5
Class
None
0
SortingClass
Kits
1
____________ Durability ____________
____________
____________
Flashpoint Temperature
700℃
Autoignition Temperature
1200℃
Passive vents allow gases to move into and out of pipe networks, which are closed systems unless connected to a device or structure. Passive vents are not powered, merely an aperture, essentially turning an enclosed space into part of the pipe network.
Passive Vent
PV
____________ General ____________
______________
______________
Paintable
✔
Prefab Hash
335498166
Prefab Name
StructurePassiveVent
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Passive Vent)
1
.............................................................
.........................
.........................
Deconstruction Tool
Wrench
____________ Internal ____________
____________
______________
Volume
100 l
Max Pressure
60,800 kPa
Convection
0.011
Radiation
0.001
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Pipe
0
Used to mix atmospheres passively between two walls.
Wall Vent
____________ General ____________
______________
______________
Paintable
✔
Prefab Hash
-1177469307
Prefab Name
StructureWallVent
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Passive Vent)
1
.............................................................
.........................
.........................
Deconstruction Tool
Wrench
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
This creates a Pipe Cowl that can be placed on the end of pipes to expose them to the world atmospheres.
Kit (Pipe Cowl)
____________ General ____________
____________
____________
Paintable
✔
Prefab Hash
-38898376
Prefab Name
ItemPipeCowl
______________ Item ______________
____________
____________
Stack Size
20
Class
None
0
SortingClass
Kits
1
____________ Durability ____________
____________
____________
Flashpoint Temperature
700℃
Autoignition Temperature
1200℃
Pipe Cowl
____________ General ____________
______________
______________
Paintable
✔
Prefab Hash
465816159
Prefab Name
StructurePipeCowl
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Pipe Cowl)
1
.............................................................
.........................
.........................
Deconstruction Tool
Wrench
____________ Internal ____________
____________
______________
Volume
10 l
Max Pressure
60,795 kPa
Convection
0.003
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
None
Width
1
Connections
Port
Description
Pipe
0
Kit (Powered Vent)
____________ General ____________
____________
____________
Paintable
✔
Prefab Hash
2015439334
Prefab Name
ItemKitPoweredVent
______________ Item ______________
____________
____________
Stack Size
5
Class
None
0
SortingClass
Kits
1
____________ Durability ____________
____________
____________
Flashpoint Temperature
NA
Autoignition Temperature
NA
Great for moving large quantities of air into a pipe network. Its primary purpose is for the creation of multi-grid airlocks. It can effeciently pull a vacuum on a small to medium sized room.
Powered Vent
AVM
____________ General ____________
______________
______________
Paintable
✔
Prefab Hash
938836756
Prefab Name
StructurePoweredVent
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Powered Vent)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
Upgrade Tool
Screwdriver
.............................................................
.........................
.........................
Deconstruction Tool
Wrench
Upgrade Tool
Welding Torch
Upgrade Cost
Plastic Sheets
2
.............................................................
.........................
.........................
Deconstruction Tool
Angle Grinder
____________ Power ____________
____ Min ____
____ Max ____
Power Use
250W
250W
Heat Generation
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
2
Required Support
Wall
Width
2
Mode
Name
Description
0
Outward
Push gas from the pipe into the world atmosphere, until external pressure reaches PressureExternal .
1
Inward
Pull gas from the world atmosphere into the pipe, until external pressure reaches PressureExternal .
Connections
Port
Description
Data
0
Pipe Output
1
Power
2
Structure (Powered Vent Large)
For building large scale airlock systems and pressurised hangers, a bigger and bolder version of the Powered Vent that can effeciently pull a vacuum in large room.
Powered Vent Large
AVL
____________ General ____________
______________
______________
Paintable
✔
Prefab Hash
-785498334
Prefab Name
StructurePoweredVentLarge
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Powered Vent)
2
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
Upgrade Tool
Screwdriver
.............................................................
.........................
.........................
Deconstruction Tool
Wrench
Upgrade Tool
Welding Torch
Upgrade Cost
Plastic Sheets
2
.............................................................
.........................
.........................
Deconstruction Tool
Angle Grinder
____________ Power ____________
____ Min ____
____ Max ____
Power Use
500W
500W
Heat Generation
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
3
Required Support
Wall
Width
3
Mode
Name
Description
0
Outward
Push gas from the pipe into the world atmosphere, until external pressure reaches PressureExternal .
1
Inward
Pull gas from the world atmosphere into the pipe, until external pressure reaches PressureExternal .
Connections
Port
Description
Data
0
Pipe Output
1
Power
2