Pipes - Niilo007/Stationeers-Research GitHub Wiki


Gas Pipes

  • Gas pipes will start taking damage if the volume of liquid exceeds 2% of the total volume.

Kit (Pipe)

Kit (Pipe)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash -1619793705
Prefab Name ItemKitPipe
______________ Item ______________ ____________ ____________
Stack Size 20
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 700℃
Autoignition Temperature 1200℃
___________ Tradeable ? ___________ ____________ ____________
Buy Price €0.50
Sell Price NA
Made In Autolathe T1 Autolathe T2 Hydraulic Pipe Bender T1 Hydraulic Pipe Bender T2
alt text alt text alt text alt text
Time
Energy 200 500
Iron Fe 0.5g 0.5g 0.5g 0.5g

Structure (Pipe (Straight))

The first thing a Stationeer learns, is that they are alone. The second is that pipes store gas. Pipes spread their contents evenly through the entire network, and can be connected to a huge range of devices and structures. Basic pipes can withstand pressures of up to 60MPa. Beyond that, things get 'interesting'.

Pipe (Straight)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 73728932
Prefab Name StructurePipeStraight
___________ Durability ___________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Pipe) 1
............................................................. ......................... .........................
Deconstruction Tool Wrench
____________ Internal ____________ ______________ ______________
Volume 10 l
Max Pressure 60,795 kPa
Convection 0.005
Radiation
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support None Width 1
Connections Port Description
Pipe 0
Pipe 1

Structure (Pipe (Shapes))

Image Shape Prefab Hash Prefab Name Cost Volume Convection Radiation
Straight 73728932 StructurePipeStraight 1x 10 l 0.005
Corner -1785673561 StructurePipeCorner 1x 10 l 0.005
T Junction -913817472 StructurePipeTJunction 2x 10 l 0.007
Cross Junction -1405295588 StructurePipeCrossJunction 2x 10 l 0.009
5-Way Junction -1877193979 StructurePipeCrossJunction5 3x 10 l 0.012 0.001
6-Way Junction 152378047 StructurePipeCrossJunction6 3x 10 l 0.015 0.001
3-Way Junction 2038427184 StructurePipeCrossJunction3 2x 10 l 0.007
4-Way Junction -417629293 StructurePipeCrossJunction4 3x 10 l 0.009

Kit (Insulated Pipe)

This kit produces varieties of Insulated Pipe (Straight), which greatly reduce heat loss from gases stored in them.

Kit (Insulated Pipe)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 452636699
Prefab Name ItemKitInsulatedPipe
______________ Item ______________ ____________ ____________
Stack Size 20
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 700℃
Autoignition Temperature 1200℃
Made In Hydraulic Pipe Bender T1 Hydraulic Pipe Bender T2
alt text alt text
Time
Energy 500
Steel 1g 1g
Silicon Si 1g 1g

Structure (Insulated Pipe Straight)

Insulated pipes greatly reduce heat loss from gases stored in them.

Insulated Pipe (Straight)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 2134172356
Prefab Name StructureInsulatedPipeStraight
___________ Durability ___________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Insulated Pipe) 1
............................................................. ......................... .........................
Deconstruction Tool Wrench
____________ Internal ____________ ______________ ______________
Volume 10 l
Max Pressure 60,795 kPa
Convection 0
Radiation 0
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support None Width 1
Connections Port Description
Pipe 0
Pipe 1

Structure (Insulated Pipe (Shapes))

Image Shape Prefab Hash Prefab Name Cost Volume Convection Radiation
Straight 2134172356 StructureInsulatedPipeStraight 1x 10 l 0 0
Corner -1967711059 StructureInsulatedPipeCorner 1x 10 l 0 0
T Junction -2076086215 StructureInsulatedPipeTJunction 2x 10 l 0 0
Cross Junction -92778058 StructureInsulatedPipeCrossJunction 2x 10 l 0 0
5-Way Junction -1505147578 StructureInsulatedPipeCrossJunction5 3x 10 l 0 0
6-Way Junction 1061164284 StructureInsulatedPipeCrossJunction6 3x 10 l 0 0
3-Way Junction 1328210035 StructureInsulatedPipeCrossJunction3 2x 10 l 0 0
4-Way Junction -783387184 StructureInsulatedPipeCrossJunction4 3x 10 l 0 0

Liquid Pipes


Kit (Liquid Pipe)

This kit produces a range of liquid pipes.

Kit (Liquid Pipe)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash -1166461357
Prefab Name ItemKitPipeLiquid
______________ Item ______________ ____________ ____________
Stack Size 20
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 700℃
Autoignition Temperature 1200℃
Made In Hydraulic Pipe Bender T1 Hydraulic Pipe Bender T2
alt text alt text
Time
Energy 500
Iron Fe 0.5g 0.5g

Structure (Liquid Pipe Straight)

It's all in the title - liquid pipes create pipe networks for the storage and transport of matter's second state: liquid.

Liquid Pipe (Straight)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 667597982
Prefab Name StructurePipeLiquidStraight
___________ Durability ___________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Liquid Pipe) 1
............................................................. ......................... .........................
Deconstruction Tool Wrench
____________ Internal ____________ ______________ ______________
Volume 20 l
Max Pressure 6079.5 kPa
Convection 0.005
Radiation
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support None Width 1
Connections Port Description
Pipe Liquid 0
Pipe Liquid 1

Structure (Liquid Pipe (Shapes))

Image Shape Prefab Hash Prefab Name Cost Volume Convection Radiation
Straight 667597982 StructurePipeLiquidStraight 1x 20 l 0.005
Corner -1856720921 StructurePipeLiquidCorner 1x 20 l 0.006
T Junction 262616717 StructurePipeLiquidTJunction 2x 20 l 0.007
Cross Junction 1848735691 StructurePipeLiquidCrossJunction 2x 20 l 0.01
5-Way Junction -2006384159 StructurePipeLiquidCrossJunction5 3x 20 l 0.013 0.001
6-Way Junction 291524699 StructurePipeLiquidCrossJunction6 3x 20 l 0.017 0.001
3-Way Junction 1628087508 StructurePipeLiquidCrossJunction3 2x 20 l 0.008
4-Way Junction -9555593 StructurePipeLiquidCrossJunction4 3x 20 l 0.01 0.001

Kit (Insulated Liquid Pipe)

Kit (Insulated Liquid Pipe)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 2067655311
Prefab Name ItemKitInsulatedLiquidPipe
______________ Item ______________ ____________ ____________
Stack Size 20
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 700℃
Autoignition Temperature 1200℃
Made In Hydraulic Pipe Bender T1 Hydraulic Pipe Bender T2
alt text alt text
Time
Energy 500
Steel 1g 1g
Silicon Si 1g 1g

Structure (Insulated Liquid Pipe (Straight))

Liquid piping with very low temperature loss or gain.

Insulated Liquid Pipe (Straight)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 295678685
Prefab Name StructureInsulatedPipeLiquidStraight
___________ Durability ___________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Insulated Liquid Pipe) 1
............................................................. ......................... .........................
Deconstruction Tool Wrench
____________ Internal ____________ ______________ ______________
Volume 20 l
Max Pressure 6079.5 kPa
Convection 0
Radiation 0
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support None Width 1
Connections Port Description
Pipe Liquid 0
Pipe Liquid 1

Structure (Insulated Liquid Pipe (Shapes))

Image Shape Prefab Hash Prefab Name Cost Volume Convection Radiation
Straight 295678685 StructureInsulatedPipeLiquidStraight 1x 20 l 0 0
Corner 1713710802 StructureInsulatedPipeLiquidCorner 1x 20 l 0 0
T Junction -532384855 StructureInsulatedPipeLiquidTJunction 2x 20 l 0 0
Cross Junction -2068497073 StructureInsulatedPipeLiquidCrossJunction 2x 20 l 0 0
5-Way Junction 1654694384 StructureInsulatedPipeLiquidCrossJunction5 3x 20 l 0 0
6-Way Junction -72748982 StructureInsulatedPipeLiquidCrossJunction6 3x 20 l 0 0
3-Way Junction 1926651727 StructureInsulatedPipeLiquidCrossJunction3 2x 20 l 0 0
4-Way Junction 363303270 StructureInsulatedPipeLiquidCrossJunction4 3x 20 l 0 0

⚠️ **GitHub.com Fallback** ⚠️