Kit (Pipe Utility Gas)
____________ General ____________
____________
____________
Paintable
✔
Nameable
❌
Prefab Hash
1934508338
Prefab Name
ItemKitPipeUtility
______________ Item ______________
____________
____________
Stack Size
10
Class
None
0
SortingClass
Default*
0
____________ Durability ____________
____________
____________
Flashpoint Temperature
NA
Autoignition Temperature
NA
Structure (In-Line Tank Small Gas)
A small expansion tank that increases the volume of a pipe network.
Inline tanks increase the volume of the pipe network they are a part of.
In-Line Tank Small Gas
____________ General ____________
______________
______________
Paintable
✔
Nameable
❌
Prefab Hash
-1693382705
Prefab Name
StructureInLineTankGas1x1
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Pipe Utility Gas)
1
.............................................................
.........................
.........................
Deconstruction Tool
Wrench
____________ Internal ____________
____________
______________
Volume
100 l
Max Pressure
60,795 kPa
Convection
0.015
Radiation
0.001
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
None
Width
1
Connections
Pipe
0
Pipe
1
Structure (In-Line Tank Gas)
A small expansion tank that increases the volume of a pipe network.
Inline tanks increase the volume of the pipe network they are a part of.
In-Line Tank Gas
____________ General ____________
______________
______________
Paintable
✔
Nameable
❌
Prefab Hash
35149429
Prefab Name
StructureInLineTankGas1x2
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Pipe Utility Gas)
2
.............................................................
.........................
.........................
Deconstruction Tool
Wrench
____________ Internal ____________
____________
______________
Volume
250 l
Max Pressure
60,795 kPa
Convection
0.025
Radiation
0.001
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
2
Required Support
None
Width
1
Connections
Pipe
0
Pipe
1
Structure (Gas Tank Storage)
When connected to a pipe network, the tank storage unit allows you to refill a Gas Canister , as well as read various atmospheric data from the gas canister slot.
Used to connect Gas Canisters to a pipe network.
Can be used without a pipe connection as storage for canisters.
The canister in the slot can be opened by writing to the Open
slot variable.
The canister in the slot will convect heat to the surrounding atmosphere.
Gas Tank Storage
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
1632165346
Prefab Name
StructureGasTankStorage
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Pipe Utility Gas)
1
.............................................................
.........................
.........................
Deconstruction Tool
Wrench
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
2
Required Support
None
Width
1
Connections
Data
0
Pipe Input
1