Liquid Drains - Niilo007/Stationeers-Research GitHub Wiki


Liquid Drains


Kit (Liquid Drain)

Kit (Liquid Drain)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 2036225202
Prefab Name ItemLiquidDrain
______________ Item ______________ ____________ ____________
Stack Size 5
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 1200℃
Autoignition Temperature 800℃
Made In Hydraulic Pipe Bender T1 Hydraulic Pipe Bender T2
alt text alt text
Time
Energy 500
Iron Fe 5g 5g
Copper Cu 2g 2g

Structure (Passive Liquid Inlet)

A passive liquid floor inlet that quickly removes liquids in one direction from the world into the connected pipe network. It will equalise gasses with the world atmosphere also.

Passive Liquid Inlet
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 1048813293
Prefab Name StructureFloorDrain
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Liquid Drain) 1
............................................................. ......................... .........................
Deconstruction Tool Wrench
____________ Internal ____________ ______________ ______________
Volume 20 l
Max Pressure 6,080 kPa
Convection 0.011
Radiation 0.001
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support Wall Width 1
Connections Port Description
Pipe Liquid 0

Structure (Active Liquid Outlet)

When connected to power and activated, it pumps liquid from a liquid network into the world.

Active Liquid Outlet
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 1687692899
Prefab Name StructureLiquidDrain
____________ Durability ____________ ______________ ______________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
_________ Construction _________ ______________ ______________
Placement Cost Kit (Liquid Drain) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
____________ Power ____________ ____ Min ____ ____ Max ____
Power Use 50W 50W
Heat Generation
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support Wall Width 1
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
Power bool 0 1
Error bool 0 1
Lock bool 0 1
Setting int 0 100
Maximum int 100 100
Ratio float 0 1
On bool 0 1
RequiredPower int 0 50
PrefabHash int 1687692899 1687692899
ReferenceId int
Connections Port Description
Pipe Liquid 0
Data Input 1
Power Input 2

Structure (Passive Liquid Drain)

Moves liquids from a pipe network to the world atmosphere.

Passive Liquid Drain
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 1812364811
Prefab Name StructurePassiveLiquidDrain
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Liquid Drain) 1
............................................................. ......................... .........................
Deconstruction Tool Wrench
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support Gas Pipe Width 1
Show Inaccessible Data:
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
Pressure float 0 0
Temperature float 0 0
RatioOxygen float 0 0
RatioCarbonDioxide float 0 0
RatioNitrogen float 0 0
RatioPollutant float 0 0
RatioVolatiles float 0 0
RatioWater float 0 0
TotalMoles float 0 0
RatioNitrousOxide float 0 0
PrefabHash int 1812364811 1812364811
Combustion bool 0 0
ReferenceId int

⚠️ **GitHub.com Fallback** ⚠️