Kit (Liquid Drain)
____________ General ____________
____________
____________
Paintable
✔
Nameable
❌
Prefab Hash
2036225202
Prefab Name
ItemLiquidDrain
______________ Item ______________
____________
____________
Stack Size
5
Class
None
0
SortingClass
Kits
1
____________ Durability ____________
____________
____________
Flashpoint Temperature
1200℃
Autoignition Temperature
800℃
Structure (Passive Liquid Inlet)
A passive liquid floor inlet that quickly removes liquids in one direction from the world into the connected pipe network. It will equalise gasses with the world atmosphere also.
Passive Liquid Inlet
____________ General ____________
______________
______________
Paintable
✔
Nameable
❌
Prefab Hash
1048813293
Prefab Name
StructureFloorDrain
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Liquid Drain)
1
.............................................................
.........................
.........................
Deconstruction Tool
Wrench
____________ Internal ____________
______________
______________
Volume
20 l
Max Pressure
6,080 kPa
Convection
0.011
Radiation
0.001
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Pipe Liquid
0
Structure (Active Liquid Outlet)
When connected to power and activated, it pumps liquid from a liquid network into the world.
Active Liquid Outlet
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
1687692899
Prefab Name
StructureLiquidDrain
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Liquid Drain)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
50W
50W
Heat Generation
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Pipe Liquid
0
Data Input
1
Power Input
2
Structure (Passive Liquid Drain)
Moves liquids from a pipe network to the world atmosphere.
Passive Liquid Drain
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
1812364811
Prefab Name
StructurePassiveLiquidDrain
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Liquid Drain)
1
.............................................................
.........................
.........................
Deconstruction Tool
Wrench
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Gas Pipe
Width
1
Show Inaccessible Data: