This kit produces a range of Console s and displays such as the LED Display (Medium) .
Kit (Consoles)
____________ General ____________
____________
____________
Paintable
✔
Nameable
❌
Prefab Hash
-1241851179
Prefab Name
ItemKitConsole
______________ Item ______________
____________
____________
Stack Size
5
Class
None
0
SortingClass
Kits
1
____________ Durability ____________
____________
____________
Flashpoint Temperature
700℃
Autoignition Temperature
1200℃
This Norsec-designed control box manages devices such as the Active Vent , Passive Vent , Gas Sensor and Composite Door , depending on which circuitboard is inserted into the unit. It has a shared data/power port.
A completed console displays all devices connected to the current power network. Any devices not related to the installed circuitboard will be greyed-out and inoperable. Consoles are locked once a Data Disk is removed.
The image on the screen will automatically rotate to be right side up, When the console is placed sideways or upside down.
The selected Circuit Board is added under the glass panel.
The panel must therefore be removed with a crowbar , to gain access.
To change the settings, a data disk must be inserted into the slot.
Console
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
235638270
Prefab Name
StructureConsole
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Consoles)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
Upgrade Cost
Glass Sheets
1
.............................................................
.........................
.........................
Deconstruction Tool
Crowbar
____________ Power ____________
____ Min ____
____ Max ____
Power Use
50W
50W
Heat Generation
10W
10W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Show Dimensions:
solid cube
facet normal 0.0 0.0 1.0 //Bottom, OK
outer loop vertex 0.0 0.0 0.0 vertex 2.5 2.5 0.0 vertex 2.5 0.0 0.0 endloop
endfacet
facet normal 0.0 0.0 1.0 //Bottom, OK
outer loop vertex 0.0 0.0 0.0 vertex 0.0 2.5 0.0 vertex 2.5 2.5 0.0 endloop
endfacet
facet normal 0.0 0.0 -1.0 //Top, OK
outer loop vertex 0.0 0.0 2.5 vertex 2.5 0.0 2.5 vertex 2.5 2.5 2.5 endloop
endfacet
facet normal 0.0 0.0 -1.0 //Top, OK
outer loop vertex 0.0 0.0 2.5 vertex 2.5 2.5 2.5 vertex 0.0 2.5 2.5 endloop
endfacet
facet normal -1.0 0.0 0.0 //Left Side (From Viewer)
outer loop vertex 0.0 0.0 0.0 vertex 0.0 0.0 2.5 vertex 0.0 2.5 0.0 endloop
endfacet
facet normal -1.0 0.0 0.0 //Left Side (From Viewer)
outer loop vertex 0.0 0.0 2.5 vertex 0.0 2.5 2.5 vertex 0.0 2.5 0.0 endloop
endfacet
facet normal 1.0 0.0 0.0 //Right Side (From Viewer)
outer loop vertex 2.5 0.0 0.0 vertex 2.5 2.5 0.0 vertex 2.5 0.0 2.5 endloop
endfacet
facet normal 1.0 0.0 0.0 //Right Side (From Viewer)
outer loop vertex 2.5 0.0 2.5 vertex 2.5 2.5 0.0 vertex 2.5 2.5 2.5 endloop
endfacet
facet normal 0.0 -1.0 0.0 //Facing Viewer (Front)
outer loop vertex 0.0 0.0 0.0 vertex 2.5 0.0 0.0 vertex 0.0 0.0 2.5 endloop
endfacet
facet normal 0.0 -1.0 0.0 //Facing Viewer (Front)
outer loop vertex 0.0 0.0 2.5 vertex 2.5 0.0 0.0 vertex 2.5 0.0 2.5 endloop
endfacet
facet normal 0.0 1.0 0.0 // Back
outer loop vertex 0.0 2.5 0.0 vertex 0.0 2.5 2.5 vertex 2.5 2.5 0.0 endloop
endfacet
facet normal 0.0 1.0 0.0 // Back
outer loop vertex 0.0 2.5 2.5 vertex 2.5 2.5 2.5 vertex 2.5 2.5 0.0 endloop
endfacet
facet normal 0.0 0.0 -1.0 //Power In Indicator
outer loop vertex 2.5 1.25 -2.5 vertex 1.25 1.25 0 vertex 0 1.25 -2.5 endloop
endfacet
endsolid
Loading
Connections
Port
Description
Power And Data
0
This Norsec-designed control box manages devices such as the Active Vent , Gas Sensor , Composite Door and others, depending on which circuitboard is inserted into the unit. It has separate data and power ports.
A completed console displays all devices connected to the current power network. Any devices not related to the installed circuitboard will be greyed-out and inoperable. Consoles are locked once a Data Disk is removed.
The image on the screen will automatically rotate to be right side up, When the console is placed sideways or upside down.
The selected Circuit Board is added under the glass panel.
The panel must therefore be removed with a crowbar , to gain access.
To change the settings, a data disk must be inserted into the slot.
Console Dual
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-722284333
Prefab Name
StructureConsoleDual
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Consoles)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
Upgrade Cost
Glass Sheets
1
.............................................................
.........................
.........................
Deconstruction Tool
Crowbar
____________ Power ____________
____ Min ____
____ Max ____
Power Use
50W
50W
Heat Generation
10W
10W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Show Dimensions:
solid cube
facet normal 0.0 0.0 1.0 //Bottom, OK
outer loop vertex 0.0 0.0 0.0 vertex 2.5 2.5 0.0 vertex 2.5 0.0 0.0 endloop
endfacet
facet normal 0.0 0.0 1.0 //Bottom, OK
outer loop vertex 0.0 0.0 0.0 vertex 0.0 2.5 0.0 vertex 2.5 2.5 0.0 endloop
endfacet
facet normal 0.0 0.0 -1.0 //Top, OK
outer loop vertex 0.0 0.0 2.5 vertex 2.5 0.0 2.5 vertex 2.5 2.5 2.5 endloop
endfacet
facet normal 0.0 0.0 -1.0 //Top, OK
outer loop vertex 0.0 0.0 2.5 vertex 2.5 2.5 2.5 vertex 0.0 2.5 2.5 endloop
endfacet
facet normal -1.0 0.0 0.0 //Left Side (From Viewer)
outer loop vertex 0.0 0.0 0.0 vertex 0.0 0.0 2.5 vertex 0.0 2.5 0.0 endloop
endfacet
facet normal -1.0 0.0 0.0 //Left Side (From Viewer)
outer loop vertex 0.0 0.0 2.5 vertex 0.0 2.5 2.5 vertex 0.0 2.5 0.0 endloop
endfacet
facet normal 1.0 0.0 0.0 //Right Side (From Viewer)
outer loop vertex 2.5 0.0 0.0 vertex 2.5 2.5 0.0 vertex 2.5 0.0 2.5 endloop
endfacet
facet normal 1.0 0.0 0.0 //Right Side (From Viewer)
outer loop vertex 2.5 0.0 2.5 vertex 2.5 2.5 0.0 vertex 2.5 2.5 2.5 endloop
endfacet
facet normal 0.0 -1.0 0.0 //Facing Viewer (Front)
outer loop vertex 0.0 0.0 0.0 vertex 2.5 0.0 0.0 vertex 0.0 0.0 2.5 endloop
endfacet
facet normal 0.0 -1.0 0.0 //Facing Viewer (Front)
outer loop vertex 0.0 0.0 2.5 vertex 2.5 0.0 0.0 vertex 2.5 0.0 2.5 endloop
endfacet
facet normal 0.0 1.0 0.0 // Back
outer loop vertex 0.0 2.5 0.0 vertex 0.0 2.5 2.5 vertex 2.5 2.5 0.0 endloop
endfacet
facet normal 0.0 1.0 0.0 // Back
outer loop vertex 0.0 2.5 2.5 vertex 2.5 2.5 2.5 vertex 2.5 2.5 0.0 endloop
endfacet
facet normal 0.0 0.0 -1.0 //Power In Indicator
outer loop vertex 2.5 1.25 -2.5 vertex 1.25 1.25 0 vertex 0 1.25 -2.5 endloop
endfacet
facet normal 0.0 0.0 -1.0 //Data Indicator
outer loop vertex 1.25 1.25 2.5 vertex 2.5 1.25 3.75 vertex 0 1.25 3.75 endloop
endfacet
endsolid
Loading
Connections
Port
Description
Data
0
Power
1
Structure (Console Monitor)
This Norsec-designed control box manages devices such as the Active Vent , Passive Vent , Gas Sensor , Security Camera and Composite Door , depending on which circuitboard is inserted into the unit. It has a shared data/power port, and a charming sloped interface.
A completed console displays all devices connected to the current power network. Any devices not related to the installed circuitboard will be greyed-out and inoperable. Consoles are locked once a Data Disk is removed.
The image on the screen will automatically rotate to be right side up, When the console is placed sideways or upside down.
The selected Circuit Board is added under the glass panel.
The panel must therefore be removed with a crowbar , to gain access.
To change the settings, a data disk must be inserted into the slot.
Console Monitor
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
801677497
Prefab Name
StructureConsoleMonitor
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Consoles)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
Upgrade Cost
Glass Sheets
1
.............................................................
.........................
.........................
Deconstruction Tool
Crowbar
____________ Power ____________
____ Min ____
____ Max ____
Power Use
50W
50W
Heat Generation
10W
10W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Power And Data
0
Structure (LED Display (Small))
LED Display (Small)
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-815193061
Prefab Name
StructureConsoleLED5
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Consoles)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
50W
50W
Heat Generation
10W
10W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Show Dimensions:
solid cube
facet normal 0.0 0.0 1.0 //Bottom, OK
outer loop vertex 0.0 0.0 0.0 vertex 2.5 2.5 0.0 vertex 2.5 0.0 0.0 endloop
endfacet
facet normal 0.0 0.0 1.0 //Bottom, OK
outer loop vertex 0.0 0.0 0.0 vertex 0.0 2.5 0.0 vertex 2.5 2.5 0.0 endloop
endfacet
facet normal 0.0 0.0 -1.0 //Top, OK
outer loop vertex 0.0 0.0 2.5 vertex 2.5 0.0 2.5 vertex 2.5 2.5 2.5 endloop
endfacet
facet normal 0.0 0.0 -1.0 //Top, OK
outer loop vertex 0.0 0.0 2.5 vertex 2.5 2.5 2.5 vertex 0.0 2.5 2.5 endloop
endfacet
facet normal -1.0 0.0 0.0 //Left Side (From Viewer)
outer loop vertex 0.0 0.0 0.0 vertex 0.0 0.0 2.5 vertex 0.0 2.5 0.0 endloop
endfacet
facet normal -1.0 0.0 0.0 //Left Side (From Viewer)
outer loop vertex 0.0 0.0 2.5 vertex 0.0 2.5 2.5 vertex 0.0 2.5 0.0 endloop
endfacet
facet normal 1.0 0.0 0.0 //Right Side (From Viewer)
outer loop vertex 2.5 0.0 0.0 vertex 2.5 2.5 0.0 vertex 2.5 0.0 2.5 endloop
endfacet
facet normal 1.0 0.0 0.0 //Right Side (From Viewer)
outer loop vertex 2.5 0.0 2.5 vertex 2.5 2.5 0.0 vertex 2.5 2.5 2.5 endloop
endfacet
facet normal 0.0 -1.0 0.0 //Facing Viewer (Front)
outer loop vertex 0.0 0.0 0.0 vertex 2.5 0.0 0.0 vertex 0.0 0.0 2.5 endloop
endfacet
facet normal 0.0 -1.0 0.0 //Facing Viewer (Front)
outer loop vertex 0.0 0.0 2.5 vertex 2.5 0.0 0.0 vertex 2.5 0.0 2.5 endloop
endfacet
facet normal 0.0 1.0 0.0 // Back
outer loop vertex 0.0 2.5 0.0 vertex 0.0 2.5 2.5 vertex 2.5 2.5 0.0 endloop
endfacet
facet normal 0.0 1.0 0.0 // Back
outer loop vertex 0.0 2.5 2.5 vertex 2.5 2.5 2.5 vertex 2.5 2.5 0.0 endloop
endfacet
facet normal 0.0 0.0 -1.0 //Power In Indicator
outer loop vertex 2.5 1.25 -2.5 vertex 1.25 1.25 0 vertex 0 1.25 -2.5 endloop
endfacet
endsolid
Loading
Mode
Name
Description
0
Default
Displays the raw value of Setting .
1
Percent
A value of "1" is displayed as "100%", "0" as "0%" and "2" as "200%".
2
Power
Displays the value as Watts , "100" is displayed as "100W" and "1000" as "1kW".
Connections
Port
Description
Power And Data
0
Structure (LED Display (Medium))
LED Display (Medium)
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-53151617
Prefab Name
StructureConsoleLED1x2
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Consoles)
2
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
50W
50W
Heat Generation
10W
10W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
2
Mode
Name
Description
0
Default
Displays the raw value of Setting .
1
Percent
A value of "1" is displayed as "100%", "0" as "0%" and "2" as "200%".
2
Power
Displays the value as Watts , "100" is displayed as "100W" and "1000" as "1kW".
Connections
Port
Description
Power And Data
0
Structure (LED Display (Large))
LED Display (Large)
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-1949054743
Prefab Name
StructureConsoleLED1x3
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Consoles)
3
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
50W
50W
Heat Generation
10W
10W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
3
Mode
Name
Description
0
Default
Displays the raw value of Setting .
1
Percent
A value of "1" is displayed as "100%", "0" as "0%" and "2" as "200%".
2
Power
Displays the value as Watts , "100" is displayed as "100W" and "1000" as "1kW".
Connections
Port
Description
Power And Data
0