Regulators - Niilo007/Stationeers-Research GitHub Wiki
This kit produces a single Pressure Regulator.
Kit (Pressure Regulator) | ||
---|---|---|
![]() |
||
____________ General ____________ | ____________ | ____________ |
Paintable | ❌ | |
Prefab Hash | 1181371795 | |
Prefab Name | ItemKitRegulator | |
______________ Item ______________ | ____________ | ____________ |
Stack Size | 5 | |
Class | None | 0 |
SortingClass | Kits | 1 |
____________ Durability ____________ | ____________ | ____________ |
Flashpoint Temperature | 700℃ | |
Autoignition Temperature | 1200℃ |
Made In | Hydraulic Pipe Bender T1 | Hydraulic Pipe Bender T2 |
---|---|---|
![]() |
![]() |
|
Time | ||
Energy | 500 | |
Iron Fe |
5g | 5g |
Gold Au |
1g | 1g |
Copper Cu |
2g | 2g |
Controlling the flow of gas between two pipe networks, pressure regulators shift gas until a set pressure on the outlet side is achieved, or the gas supply is exhausted. The back pressure regulator, by contrast, will only operate when pressure on the intake side exceeds the set value. With a max pressure of over 20,000kPa, it requires power to operate.
Pressure Regulator | PR | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Prefab Hash | 209854039 | |
Prefab Name | StructurePressureRegulator | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Pressure Regulator) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Hand Drill | |
____________ Power ____________ | ____ Min ____ | ____ Max ____ |
Power Use | 100W | 100W |
Heat Generation | 20W | 20W |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Power | bool | 0 | 1 | ✔ | ❌ | |
Error | bool | 0 | 1 | ✔ | ❌ | |
Lock | bool | 0 | 1 | ✔ | ✔ | |
Setting | float | 0 | 60,795 | ✔ | ✔ | Sets minimum output pressure, in kPa. |
Maximum | int | 60,795 | 60,795 | ✔ | ❌ | |
Ratio | float | 0 | 1 | ✔ | ❌ | |
On | bool | 0 | 1 | ✔ | ✔ | |
RequiredPower | float | -1 | 100 | ✔ | ❌ | |
PrefabHash | int | 209854039 | 209854039 | ✔ | ❌ | |
ReferenceId | int | ✔ | ❌ |
Connections | |
---|---|
Pipe Input | 0 |
Pipe Output | 1 |
Power And Data | 2 |
Unlike the Pressure Regulator, which closes when the input exceeds a given pressure, the back pressure regulator opens when input pressure reaches a given value.
Back Pressure Regulator | BPR | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Prefab Hash | -1149857558 | |
Prefab Name | StructureBackPressureRegulator | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Pressure Regulator) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Hand Drill | |
____________ Power ____________ | ____ Min ____ | ____ Max ____ |
Power Use | 100W | 100W |
Heat Generation | 20W | 20W |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Power | bool | 0 | 1 | ✔ | ❌ | |
Error | bool | 0 | 1 | ✔ | ❌ | |
Lock | bool | 0 | 1 | ✔ | ✔ | |
Setting | float | 0 | 60,795 | ✔ | ✔ | Sets maximum input pressure, in kPa. |
Maximum | int | 60,795 | 60,795 | ✔ | ❌ | |
Ratio | float | 0 | 1 | ✔ | ❌ | |
On | bool | 0 | 1 | ✔ | ✔ | |
RequiredPower | float | -1 | 100 | ✔ | ❌ | |
PrefabHash | int | -1149857558 | -1149857558 | ✔ | ❌ | |
ReferenceId | int | ✔ | ❌ |
Connections | |
---|---|
Pipe Input | 0 |
Pipe Output | 1 |
Power And Data | 2 |
Pumps gas into a liquid pipe in order to raise the pressure
Pressurant Valve | PrV | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Prefab Hash | 23052817 | |
Prefab Name | StructurePressurantValve | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Pressure Regulator) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Hand Drill | |
____________ Power ____________ | ____ Min ____ | ____ Max ____ |
Power Use | 100W | 100W |
Heat Generation | 20W | 20W |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Power | bool | 0 | 1 | ✔ | ❌ | |
Error | bool | 0 | 1 | ✔ | ❌ | |
Lock | bool | 0 | 1 | ✔ | ✔ | |
Setting | float | 0 | 60,795 | ✔ | ✔ | Sets minimum output pressure, in kPa. |
Maximum | int | 60,795 | 60,795 | ✔ | ❌ | |
Ratio | float | 0 | 1 | ✔ | ❌ | |
On | bool | 0 | 1 | ✔ | ✔ | |
RequiredPower | float | -1 | 100 | ✔ | ❌ | |
PrefabHash | int | 23052817 | 23052817 | ✔ | ❌ | |
ReferenceId | int | ✔ | ❌ |
Connections | |
---|---|
Pipe Input | 0 |
PipeLiquid Output | 1 |
Power And Data | 2 |
Allows for removal of pressurant gas and evaporated liquids from a liquid pipe. Similar in function to a Back Pressure Regulator the Purge Valve moves gas from the input liquid pipe to the output gas pipe aiming to keep the pressure of the input at the target setting.
Purge Valve | PuV | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Prefab Hash | -737232128 | |
Prefab Name | StructurePurgeValve | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Pressure Regulator) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Hand Drill | |
____________ Power ____________ | ____ Min ____ | ____ Max ____ |
Power Use | 100W | 100W |
Heat Generation | 20W | 20W |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Power | bool | 0 | 1 | ✔ | ❌ | |
Error | bool | 0 | 1 | ✔ | ❌ | |
Lock | bool | 0 | 1 | ✔ | ✔ | |
Setting | float | 0 | 60,795 | ✔ | ✔ | Sets maximum input pressure, in kPa. |
Maximum | int | 60,795 | 60,795 | ✔ | ❌ | |
Ratio | float | 0 | 1 | ✔ | ❌ | |
On | bool | 0 | 1 | ✔ | ✔ | |
RequiredPower | float | -1 | 100 | ✔ | ❌ | |
PrefabHash | int | -737232128 | -737232128 | ✔ | ❌ | |
ReferenceId | int | ✔ | ❌ |
Connections | |
---|---|
PipeLiquid Input | 0 |
Pipe Output | 1 |
Power And Data | 2 |
Kit (Liquid Regulator) | ||
---|---|---|
![]() |
||
____________ General ____________ | ____________ | ____________ |
Paintable | ❌ | |
Prefab Hash | 482248766 | |
Prefab Name | ItemKitLiquidRegulator | |
______________ Item ______________ | ____________ | ____________ |
Stack Size | 5 | |
Class | None | 0 |
SortingClass | Kits | 1 |
____________ Durability ____________ | ____________ | ____________ |
Flashpoint Temperature | 700℃ | |
Autoignition Temperature | 1200℃ |
Made In | Hydraulic Pipe Bender T1 | Hydraulic Pipe Bender T2 |
---|---|---|
![]() |
![]() |
|
Time | ||
Energy | 500 | |
Iron Fe |
5g | 5g |
Gold Au |
1g | 1g |
Copper Cu |
2g | 2g |
Regulates the volume ratio of liquid in the output Liquid pipe. This is expressed as percentage where 100 is totally full and 0 is empty.
- Acts like a one way valve for gasses, when on.
Liquid Volume Regulator | LVR | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Prefab Hash | 482248766 | |
Prefab Name | StructureLiquidPressureRegulator | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Liquid Regulator) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Hand Drill | |
____________ Power ____________ | ____ Min ____ | ____ Max ____ |
Power Use | 100W | 100W |
Heat Generation | 20W | 20W |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Power | bool | 0 | 1 | ✔ | ❌ | |
Error | bool | 0 | 1 | ✔ | ❌ | |
Lock | bool | 0 | 1 | ✔ | ✔ | |
Setting | float | 0 | 100 | ✔ | ✔ | Sets minimum liquid volume of output, in %. |
Maximum | int | 100 | 100 | ✔ | ❌ | |
Ratio | float | 0 | 1 | ✔ | ❌ | |
On | bool | 0 | 1 | ✔ | ✔ | |
RequiredPower | float | -1 | 100 | ✔ | ❌ | |
PrefabHash | int | 482248766 | 482248766 | ✔ | ❌ | |
ReferenceId | int | ✔ | ❌ |
Connections | |
---|---|
PipeLiquid Input | 0 |
PipeLiquid Output | 1 |
Power And Data | 2 |
Regulates the volume ratio of liquid in the input Liquid pipe. This is expressed as percentage where 100 is totally full and 0 is empty.
- Acts like a one way valve for gasses, when on.
Liquid Back Volume Regulator | LBVR | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Prefab Hash | 2099900163 | |
Prefab Name | StructureBackLiquidPressureRegulator | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Liquid Regulator) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Hand Drill | |
____________ Power ____________ | ____ Min ____ | ____ Max ____ |
Power Use | 100W | 100W |
Heat Generation | 20W | 20W |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Power | bool | 0 | 1 | ✔ | ❌ | |
Error | bool | 0 | 1 | ✔ | ❌ | |
Lock | bool | 0 | 1 | ✔ | ✔ | |
Setting | float | 0 | 100 | ✔ | ✔ | Sets maximum liquid volume of input, in %. |
Maximum | int | 100 | 100 | ✔ | ❌ | |
Ratio | float | 0 | 1 | ✔ | ❌ | |
On | bool | 0 | 1 | ✔ | ✔ | |
RequiredPower | float | -1 | 100 | ✔ | ❌ | |
PrefabHash | int | 2099900163 | 2099900163 | ✔ | ❌ | |
ReferenceId | int | ✔ | ❌ |
Connections | |
---|---|
PipeLiquid Input | 0 |
PipeLiquid Output | 1 |
Power And Data | 2 |