Valves - Niilo007/Stationeers-Research GitHub Wiki
This kit creates a Valve.
Kit (Pipe Valve) | ||
---|---|---|
![]() |
||
____________ General ____________ | ____________ | ____________ |
Paintable | ✔ | |
Nameable | ❌ | |
Prefab Hash | 799323450 | |
Prefab Name | ItemPipeValve | |
______________ Item ______________ | ____________ | ____________ |
Stack Size | 10 | |
Class | None | 0 |
SortingClass | Default | 0 |
____________ Durability ____________ | ____________ | ____________ |
Flashpoint Temperature | 100℃ | |
Autoignition Temperature | 300℃ |
Made In | Hydraulic Pipe Bender T1 | Hydraulic Pipe Bender T2 |
---|---|---|
![]() |
![]() |
|
Time | ||
Energy | 500 | |
Iron Fe |
3g | 3g |
Copper Cu |
2g | 2g |
- Manually operated valve.
- Bi-directional.
Valve | V | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Nameable | ✔ | |
Prefab Hash | -692036078 | |
Prefab Name | StructureValve | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Pipe Valve) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Wrench |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Show Inaccessible Data:
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Setting | float | 0 | 100 | ❌ | ❌ | |
Maximum | int | 100 | 100 | ❌ | ❌ | |
Ratio | float | 0 | 1 | ❌ | ❌ | |
On | bool | 0 | 1 | ❌ | ❌ | |
PrefabHash | int | -692036078 | -692036078 | ❌ | ❌ | |
ReferenceId | int | ❌ | ❌ |
Connections | Port | Description |
---|---|---|
Pipe | 0 | |
Pipe | 1 |
The one way valve moves gas in one direction only: from input side to output side. It only permits flow if the input pressure is higher than output pressure.
- Cannot be closed, always open.
- One way.
- The one way valve is very flammable, compared to the non-flammable valve.
One Way Valve (Gas) | OWV | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Nameable | ✔ | |
Prefab Hash | 1580412404 | |
Prefab Name | StructurePipeOneWayValve | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | 100℃ | |
Autoignition Temperature | 300℃ | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Pipe Valve) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Wrench |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Show Inaccessible Data:
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Setting | float | 0 | 100 | ❌ | ❌ | |
Maximum | int | 100 | 100 | ❌ | ❌ | |
Ratio | float | 0 | 1 | ❌ | ❌ | |
PrefabHash | int | 1580412404 | 1580412404 | ❌ | ❌ | |
ReferenceId | int | ❌ | ❌ |
Connections | Port | Description |
---|---|---|
Pipe Input | 0 | |
Pipe Output | 1 |
Allows for the removal of any liquids from a gas pipe into a liquid pipe. Only allows liquids to pass in one direction.
- Manually operated valve.
- One way.
Condensation Valve | CoV | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Nameable | ✔ | |
Prefab Hash | -965741795 | |
Prefab Name | StructureCondensationValve | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Pipe Valve) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Hand Drill |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Show Inaccessible Data:
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Setting | float | 0 | 100 | ❌ | ❌ | |
Maximum | int | 100 | 100 | ❌ | ❌ | |
Ratio | float | 0 | 1 | ❌ | ❌ | |
On | bool | 0 | 1 | ❌ | ❌ | |
PrefabHash | int | -965741795 | -965741795 | ❌ | ❌ | |
ReferenceId | int | ❌ | ❌ |
Connections | Port | Description |
---|---|---|
PipeLiquid Output | 0 | |
Pipe Input | 1 |
Allows for moving liquids from a liquid pipe into a gas pipe. Only allows liquids to pass in one direction. Typically this is done to allow the liquid to evaporate into a gas as part of an airconditioning loop.
- Manually operated valve.
- One way.
Expansion Valve | ExV | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Nameable | ✔ | |
Prefab Hash | 195298587 | |
Prefab Name | StructureExpansionValve | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Pipe Valve) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Hand Drill |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Show Inaccessible Data:
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Setting | float | 0 | 100 | ❌ | ❌ | |
Maximum | int | 100 | 100 | ❌ | ❌ | |
Ratio | float | 0 | 1 | ❌ | ❌ | |
On | bool | 0 | 1 | ❌ | ❌ | |
PrefabHash | int | 195298587 | 195298587 | ❌ | ❌ | |
ReferenceId | int | ❌ | ❌ |
Connections | Port | Description |
---|---|---|
Pipe Output | 0 | |
PipeLiquid Input | 1 |
This kit creates a Digital Valve.
Kit (Digital Valve) | ||
---|---|---|
![]() |
||
____________ General ____________ | ____________ | ____________ |
Paintable | ✔ | |
Nameable | ❌ | |
Prefab Hash | -1532448832 | |
Prefab Name | ItemPipeDigitalValve | |
______________ Item ______________ | ____________ | ____________ |
Stack Size | 5 | |
Class | None | 0 |
SortingClass | Kits | 1 |
____________ Durability ____________ | ____________ | ____________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA |
Made In | Hydraulic Pipe Bender T1 | Hydraulic Pipe Bender T2 |
---|---|---|
![]() |
![]() |
|
Time | ||
Energy | 500 | |
Copper Cu |
2g | 2g |
Steel | 5g | 5g |
Invar | 3g | 3g |
The digital valve allows Stationeers to create logic-controlled valves and pipe networks.
- Bi-directional.
- Can be operated manually.
- NC
Digital Valve | DV | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Nameable | ✔ | |
Prefab Hash | -1280984102 | |
Prefab Name | StructureDigitalValve | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Digital Valve) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Hand Drill | |
____________ Power ____________ | ____ Min ____ | ____ Max ____ |
Power Use | 5W | 5W |
Heat Generation | 1W | 1W |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Power | bool | 0 | 1 | ✔ | ❌ | |
Error | bool | 0 | 1 | ✔ | ❌ | |
Lock | bool | 0 | 1 | ✔ | ✔ | |
Setting | float | 0 | 100 | ✔ | ✔ | |
Maximum | int | 100 | 100 | ✔ | ❌ | |
Ratio | float | 0 | 1 | ✔ | ❌ | |
On | bool | 0 | 1 | ✔ | ✔ | |
RequiredPower | float | -1 | 5 | ✔ | ❌ | |
PrefabHash | int | -1280984102 | -1280984102 | ✔ | ❌ | |
ReferenceId | int | ✔ | ❌ |
Connections | Port | Description |
---|---|---|
Pipe Output | 0 | |
Pipe Input | 1 | |
Power And Data | 2 |
This kit creates a Liquid Valve.
Kit (Liquid Pipe Valve) | ||
---|---|---|
![]() |
||
____________ General ____________ | ____________ | ____________ |
Paintable | ✔ | |
Nameable | ❌ | |
Prefab Hash | -2126113312 | |
Prefab Name | ItemLiquidPipeValve | |
______________ Item ______________ | ____________ | ____________ |
Stack Size | 10 | |
Class | None | 0 |
SortingClass | Default | 0 |
____________ Durability ____________ | ____________ | ____________ |
Flashpoint Temperature | 100℃ | |
Autoignition Temperature | 300℃ |
Made In | Hydraulic Pipe Bender T1 | Hydraulic Pipe Bender T2 |
---|---|---|
![]() |
![]() |
|
Time | ||
Energy | 500 | |
Iron Fe |
3g | 3g |
Copper Cu |
2g | 2g |
- Manually operated valve.
- Bi-directional.
Liquid Valve | LV | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Nameable | ✔ | |
Prefab Hash | 1849974453 | |
Prefab Name | StructureLiquidValve | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Liquid Pipe Valve) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Wrench |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Show Inaccessible Data:
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Setting | float | 0 | 100 | ❌ | ❌ | |
Maximum | int | 100 | 100 | ❌ | ❌ | |
Ratio | float | 0 | 1 | ❌ | ❌ | |
On | bool | 0 | 1 | ❌ | ❌ | |
PrefabHash | int | 1849974453 | 1849974453 | ❌ | ❌ | |
ReferenceId | int | ❌ | ❌ |
Connections | Port | Description |
---|---|---|
Pipe Liquid | 0 | |
Pipe Liquid | 1 |
The one way valve moves gas in one direction only: from input side to output side. It only permits flow if the input pressure is higher than output pressure.
- Cannot be closed, always open.
- One way.
- The one way valve is very flammable, compared to the non-flammable valve.
One Way Valve (Liquid) | LOWV | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Nameable | ✔ | |
Prefab Hash | -782453061 | |
Prefab Name | StructureLiquidPipeOneWayValve | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | 100℃ | |
Autoignition Temperature | 300℃ | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Liquid Pipe Valve) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Wrench |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Show Inaccessible Data:
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Setting | float | 0 | 100 | ❌ | ❌ | |
Maximum | int | 100 | 100 | ❌ | ❌ | |
Ratio | float | 0 | 1 | ❌ | ❌ | |
PrefabHash | int | -782453061 | -782453061 | ❌ | ❌ | |
ReferenceId | int | ❌ | ❌ |
Connections | Port | Description |
---|---|---|
PipeLiquid Input | 0 | |
PipeLiquid Output | 1 |
Kit (Liquid Digital Valve) | ||
---|---|---|
![]() |
||
____________ General ____________ | ____________ | ____________ |
Paintable | ✔ | |
Nameable | ❌ | |
Prefab Hash | 309693520 | |
Prefab Name | ItemWaterPipeDigitalValve | |
______________ Item ______________ | ____________ | ____________ |
Stack Size | 5 | |
Class | None | 0 |
SortingClass | Kits | 1 |
____________ Durability ____________ | ____________ | ____________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA |
Made In | Hydraulic Pipe Bender T1 | Hydraulic Pipe Bender T2 |
---|---|---|
![]() |
![]() |
|
Time | ||
Energy | 500 | |
Copper Cu |
2g | 2g |
Steel | 5g | 5g |
Invar | 3g | 3g |
- Bi-directional.
- Can be operated manually.
- NC
Liquid Digital Valve | LDV | |
---|---|---|
![]() |
![]() |
|
____________ General ____________ | ______________ | ______________ |
Paintable | ✔ | |
Nameable | ✔ | |
Prefab Hash | -517628750 | |
Prefab Name | StructureWaterDigitalValve | |
____________ Durability ____________ | ______________ | ______________ |
Flashpoint Temperature | NA | |
Autoignition Temperature | NA | |
_________ Construction _________ | ______________ | ______________ |
Placement Cost | Kit (Liquid Digital Valve) | 1 |
............................................................. | ......................... | ......................... |
Deconstruction Tool | Hand Drill | |
____________ Power ____________ | ____ Min ____ | ____ Max ____ |
Power Use | 5W | 5W |
Heat Generation | 1W | 1W |
Placement | Dimensions | |||
---|---|---|---|---|
Snapping | Small Grid | Length | 1 | |
Rotation | Any | Height | 1 | |
Required Support | None | Width | 1 |
Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
---|---|---|---|---|---|---|
Power | bool | 0 | 1 | ✔ | ❌ | |
Error | bool | 0 | 1 | ✔ | ❌ | |
Lock | bool | 0 | 1 | ✔ | ✔ | |
Setting | float | 0 | 100 | ✔ | ✔ | |
Maximum | int | 100 | 100 | ✔ | ❌ | |
Ratio | float | 0 | 1 | ✔ | ❌ | |
On | bool | 0 | 1 | ✔ | ✔ | |
RequiredPower | float | -1 | 5 | ✔ | ❌ | |
PrefabHash | int | -517628750 | -517628750 | ✔ | ❌ | |
ReferenceId | int | ✔ | ❌ |
Connections | Port | Description |
---|---|---|
PipeLiquid Output | 0 | |
PipeLiquid Input | 1 | |
Power And Data | 2 |