Valves - Niilo007/Stationeers-Research GitHub Wiki
This kit creates a Valve.
| Kit (Pipe Valve) | ||
|---|---|---|
![]() |
||
| ____________ General ____________ | ____________ | ____________ |
| Paintable | ✔ | |
| Nameable | ❌ | |
| Prefab Hash | 799323450 | |
| Prefab Name | ItemPipeValve | |
| ______________ Item ______________ | ____________ | ____________ |
| Stack Size | 10 | |
| Class | None | 0 |
| SortingClass | Default | 0 |
| ____________ Durability ____________ | ____________ | ____________ |
| Flashpoint Temperature | 100℃ | |
| Autoignition Temperature | 300℃ |
| Made In | Hydraulic Pipe Bender T1 | Hydraulic Pipe Bender T2 |
|---|---|---|
![]() |
![]() |
|
| Time | ||
| Energy | 500 | |
Iron Fe |
3g | 3g |
Copper Cu |
2g | 2g |
- Manually operated valve.
- Bi-directional.
| Valve | V | |
|---|---|---|
![]() |
![]() |
|
| ____________ General ____________ | ______________ | ______________ |
| Paintable | ✔ | |
| Nameable | ✔ | |
| Prefab Hash | -692036078 | |
| Prefab Name | StructureValve | |
| ____________ Durability ____________ | ______________ | ______________ |
| Flashpoint Temperature | NA | |
| Autoignition Temperature | NA | |
| _________ Construction _________ | ______________ | ______________ |
| Placement Cost | Kit (Pipe Valve) | 1 |
| ............................................................. | ......................... | ......................... |
| Deconstruction Tool | Wrench |
| Placement | Dimensions | |||
|---|---|---|---|---|
| Snapping | Small Grid | Length | 1 | |
| Rotation | Any | Height | 1 | |
| Required Support | None | Width | 1 |
Show Inaccessible Data:
| Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
|---|---|---|---|---|---|---|
| Setting | float | 0 | 100 | ❌ | ❌ | |
| Maximum | int | 100 | 100 | ❌ | ❌ | |
| Ratio | float | 0 | 1 | ❌ | ❌ | |
| On | bool | 0 | 1 | ❌ | ❌ | |
| PrefabHash | int | -692036078 | -692036078 | ❌ | ❌ | |
| ReferenceId | int | ❌ | ❌ |
| Connections | Port | Description |
|---|---|---|
| Pipe | 0 | |
| Pipe | 1 |
The one way valve moves gas in one direction only: from input side to output side. It only permits flow if the input pressure is higher than output pressure.
- Cannot be closed, always open.
- One way.
- The one way valve is very flammable, compared to the non-flammable valve.
| One Way Valve (Gas) | OWV | |
|---|---|---|
![]() |
![]() |
|
| ____________ General ____________ | ______________ | ______________ |
| Paintable | ✔ | |
| Nameable | ✔ | |
| Prefab Hash | 1580412404 | |
| Prefab Name | StructurePipeOneWayValve | |
| ____________ Durability ____________ | ______________ | ______________ |
| Flashpoint Temperature | 100℃ | |
| Autoignition Temperature | 300℃ | |
| _________ Construction _________ | ______________ | ______________ |
| Placement Cost | Kit (Pipe Valve) | 1 |
| ............................................................. | ......................... | ......................... |
| Deconstruction Tool | Wrench |
| Placement | Dimensions | |||
|---|---|---|---|---|
| Snapping | Small Grid | Length | 1 | |
| Rotation | Any | Height | 1 | |
| Required Support | None | Width | 1 |
Show Inaccessible Data:
| Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
|---|---|---|---|---|---|---|
| Setting | float | 0 | 100 | ❌ | ❌ | |
| Maximum | int | 100 | 100 | ❌ | ❌ | |
| Ratio | float | 0 | 1 | ❌ | ❌ | |
| PrefabHash | int | 1580412404 | 1580412404 | ❌ | ❌ | |
| ReferenceId | int | ❌ | ❌ |
| Connections | Port | Description |
|---|---|---|
| Pipe Input | 0 | |
| Pipe Output | 1 |
Allows for the removal of any liquids from a gas pipe into a liquid pipe. Only allows liquids to pass in one direction.
- Manually operated valve.
- One way.
| Condensation Valve | CoV | |
|---|---|---|
![]() |
![]() |
|
| ____________ General ____________ | ______________ | ______________ |
| Paintable | ✔ | |
| Nameable | ✔ | |
| Prefab Hash | -965741795 | |
| Prefab Name | StructureCondensationValve | |
| ____________ Durability ____________ | ______________ | ______________ |
| Flashpoint Temperature | NA | |
| Autoignition Temperature | NA | |
| _________ Construction _________ | ______________ | ______________ |
| Placement Cost | Kit (Pipe Valve) | 1 |
| ............................................................. | ......................... | ......................... |
| Deconstruction Tool | Hand Drill |
| Placement | Dimensions | |||
|---|---|---|---|---|
| Snapping | Small Grid | Length | 1 | |
| Rotation | Any | Height | 1 | |
| Required Support | None | Width | 1 |
Show Inaccessible Data:
| Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
|---|---|---|---|---|---|---|
| Setting | float | 0 | 100 | ❌ | ❌ | |
| Maximum | int | 100 | 100 | ❌ | ❌ | |
| Ratio | float | 0 | 1 | ❌ | ❌ | |
| On | bool | 0 | 1 | ❌ | ❌ | |
| PrefabHash | int | -965741795 | -965741795 | ❌ | ❌ | |
| ReferenceId | int | ❌ | ❌ |
| Connections | Port | Description |
|---|---|---|
| PipeLiquid Output | 0 | |
| Pipe Input | 1 |
Allows for moving liquids from a liquid pipe into a gas pipe. Only allows liquids to pass in one direction. Typically this is done to allow the liquid to evaporate into a gas as part of an airconditioning loop.
- Manually operated valve.
- One way.
| Expansion Valve | ExV | |
|---|---|---|
![]() |
![]() |
|
| ____________ General ____________ | ______________ | ______________ |
| Paintable | ✔ | |
| Nameable | ✔ | |
| Prefab Hash | 195298587 | |
| Prefab Name | StructureExpansionValve | |
| ____________ Durability ____________ | ______________ | ______________ |
| Flashpoint Temperature | NA | |
| Autoignition Temperature | NA | |
| _________ Construction _________ | ______________ | ______________ |
| Placement Cost | Kit (Pipe Valve) | 1 |
| ............................................................. | ......................... | ......................... |
| Deconstruction Tool | Hand Drill |
| Placement | Dimensions | |||
|---|---|---|---|---|
| Snapping | Small Grid | Length | 1 | |
| Rotation | Any | Height | 1 | |
| Required Support | None | Width | 1 |
Show Inaccessible Data:
| Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
|---|---|---|---|---|---|---|
| Setting | float | 0 | 100 | ❌ | ❌ | |
| Maximum | int | 100 | 100 | ❌ | ❌ | |
| Ratio | float | 0 | 1 | ❌ | ❌ | |
| On | bool | 0 | 1 | ❌ | ❌ | |
| PrefabHash | int | 195298587 | 195298587 | ❌ | ❌ | |
| ReferenceId | int | ❌ | ❌ |
| Connections | Port | Description |
|---|---|---|
| Pipe Output | 0 | |
| PipeLiquid Input | 1 |
This kit creates a Digital Valve.
| Kit (Digital Valve) | ||
|---|---|---|
![]() |
||
| ____________ General ____________ | ____________ | ____________ |
| Paintable | ✔ | |
| Nameable | ❌ | |
| Prefab Hash | -1532448832 | |
| Prefab Name | ItemPipeDigitalValve | |
| ______________ Item ______________ | ____________ | ____________ |
| Stack Size | 5 | |
| Class | None | 0 |
| SortingClass | Kits | 1 |
| ____________ Durability ____________ | ____________ | ____________ |
| Flashpoint Temperature | NA | |
| Autoignition Temperature | NA |
| Made In | Hydraulic Pipe Bender T1 | Hydraulic Pipe Bender T2 |
|---|---|---|
![]() |
![]() |
|
| Time | ||
| Energy | 500 | |
Copper Cu |
2g | 2g |
| Steel | 5g | 5g |
| Invar | 3g | 3g |
The digital valve allows Stationeers to create logic-controlled valves and pipe networks.
- Bi-directional.
- Can be operated manually.
- NC
| Digital Valve | DV | |
|---|---|---|
![]() |
![]() |
|
| ____________ General ____________ | ______________ | ______________ |
| Paintable | ✔ | |
| Nameable | ✔ | |
| Prefab Hash | -1280984102 | |
| Prefab Name | StructureDigitalValve | |
| ____________ Durability ____________ | ______________ | ______________ |
| Flashpoint Temperature | NA | |
| Autoignition Temperature | NA | |
| _________ Construction _________ | ______________ | ______________ |
| Placement Cost | Kit (Digital Valve) | 1 |
| ............................................................. | ......................... | ......................... |
| Deconstruction Tool | Hand Drill | |
| ____________ Power ____________ | ____ Min ____ | ____ Max ____ |
| Power Use | 5W | 5W |
| Heat Generation | 1W | 1W |
| Placement | Dimensions | |||
|---|---|---|---|---|
| Snapping | Small Grid | Length | 1 | |
| Rotation | Any | Height | 1 | |
| Required Support | None | Width | 1 |
| Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
|---|---|---|---|---|---|---|
| Power | bool | 0 | 1 | ✔ | ❌ | |
| Error | bool | 0 | 1 | ✔ | ❌ | |
| Lock | bool | 0 | 1 | ✔ | ✔ | |
| Setting | float | 0 | 100 | ✔ | ✔ | |
| Maximum | int | 100 | 100 | ✔ | ❌ | |
| Ratio | float | 0 | 1 | ✔ | ❌ | |
| On | bool | 0 | 1 | ✔ | ✔ | |
| RequiredPower | float | -1 | 5 | ✔ | ❌ | |
| PrefabHash | int | -1280984102 | -1280984102 | ✔ | ❌ | |
| ReferenceId | int | ✔ | ❌ |
| Connections | Port | Description |
|---|---|---|
| Pipe Output | 0 | |
| Pipe Input | 1 | |
| Power And Data | 2 |
This kit creates a Liquid Valve.
| Kit (Liquid Pipe Valve) | ||
|---|---|---|
![]() |
||
| ____________ General ____________ | ____________ | ____________ |
| Paintable | ✔ | |
| Nameable | ❌ | |
| Prefab Hash | -2126113312 | |
| Prefab Name | ItemLiquidPipeValve | |
| ______________ Item ______________ | ____________ | ____________ |
| Stack Size | 10 | |
| Class | None | 0 |
| SortingClass | Default | 0 |
| ____________ Durability ____________ | ____________ | ____________ |
| Flashpoint Temperature | 100℃ | |
| Autoignition Temperature | 300℃ |
| Made In | Hydraulic Pipe Bender T1 | Hydraulic Pipe Bender T2 |
|---|---|---|
![]() |
![]() |
|
| Time | ||
| Energy | 500 | |
Iron Fe |
3g | 3g |
Copper Cu |
2g | 2g |
- Manually operated valve.
- Bi-directional.
| Liquid Valve | LV | |
|---|---|---|
![]() |
![]() |
|
| ____________ General ____________ | ______________ | ______________ |
| Paintable | ✔ | |
| Nameable | ✔ | |
| Prefab Hash | 1849974453 | |
| Prefab Name | StructureLiquidValve | |
| ____________ Durability ____________ | ______________ | ______________ |
| Flashpoint Temperature | NA | |
| Autoignition Temperature | NA | |
| _________ Construction _________ | ______________ | ______________ |
| Placement Cost | Kit (Liquid Pipe Valve) | 1 |
| ............................................................. | ......................... | ......................... |
| Deconstruction Tool | Wrench |
| Placement | Dimensions | |||
|---|---|---|---|---|
| Snapping | Small Grid | Length | 1 | |
| Rotation | Any | Height | 1 | |
| Required Support | None | Width | 1 |
Show Inaccessible Data:
| Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
|---|---|---|---|---|---|---|
| Setting | float | 0 | 100 | ❌ | ❌ | |
| Maximum | int | 100 | 100 | ❌ | ❌ | |
| Ratio | float | 0 | 1 | ❌ | ❌ | |
| On | bool | 0 | 1 | ❌ | ❌ | |
| PrefabHash | int | 1849974453 | 1849974453 | ❌ | ❌ | |
| ReferenceId | int | ❌ | ❌ |
| Connections | Port | Description |
|---|---|---|
| Pipe Liquid | 0 | |
| Pipe Liquid | 1 |
The one way valve moves gas in one direction only: from input side to output side. It only permits flow if the input pressure is higher than output pressure.
- Cannot be closed, always open.
- One way.
- The one way valve is very flammable, compared to the non-flammable valve.
| One Way Valve (Liquid) | LOWV | |
|---|---|---|
![]() |
![]() |
|
| ____________ General ____________ | ______________ | ______________ |
| Paintable | ✔ | |
| Nameable | ✔ | |
| Prefab Hash | -782453061 | |
| Prefab Name | StructureLiquidPipeOneWayValve | |
| ____________ Durability ____________ | ______________ | ______________ |
| Flashpoint Temperature | 100℃ | |
| Autoignition Temperature | 300℃ | |
| _________ Construction _________ | ______________ | ______________ |
| Placement Cost | Kit (Liquid Pipe Valve) | 1 |
| ............................................................. | ......................... | ......................... |
| Deconstruction Tool | Wrench |
| Placement | Dimensions | |||
|---|---|---|---|---|
| Snapping | Small Grid | Length | 1 | |
| Rotation | Any | Height | 1 | |
| Required Support | None | Width | 1 |
Show Inaccessible Data:
| Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
|---|---|---|---|---|---|---|
| Setting | float | 0 | 100 | ❌ | ❌ | |
| Maximum | int | 100 | 100 | ❌ | ❌ | |
| Ratio | float | 0 | 1 | ❌ | ❌ | |
| PrefabHash | int | -782453061 | -782453061 | ❌ | ❌ | |
| ReferenceId | int | ❌ | ❌ |
| Connections | Port | Description |
|---|---|---|
| PipeLiquid Input | 0 | |
| PipeLiquid Output | 1 |
| Kit (Liquid Digital Valve) | ||
|---|---|---|
![]() |
||
| ____________ General ____________ | ____________ | ____________ |
| Paintable | ✔ | |
| Nameable | ❌ | |
| Prefab Hash | 309693520 | |
| Prefab Name | ItemWaterPipeDigitalValve | |
| ______________ Item ______________ | ____________ | ____________ |
| Stack Size | 5 | |
| Class | None | 0 |
| SortingClass | Kits | 1 |
| ____________ Durability ____________ | ____________ | ____________ |
| Flashpoint Temperature | NA | |
| Autoignition Temperature | NA |
| Made In | Hydraulic Pipe Bender T1 | Hydraulic Pipe Bender T2 |
|---|---|---|
![]() |
![]() |
|
| Time | ||
| Energy | 500 | |
Copper Cu |
2g | 2g |
| Steel | 5g | 5g |
| Invar | 3g | 3g |
- Bi-directional.
- Can be operated manually.
- NC
| Liquid Digital Valve | LDV | |
|---|---|---|
![]() |
![]() |
|
| ____________ General ____________ | ______________ | ______________ |
| Paintable | ✔ | |
| Nameable | ✔ | |
| Prefab Hash | -517628750 | |
| Prefab Name | StructureWaterDigitalValve | |
| ____________ Durability ____________ | ______________ | ______________ |
| Flashpoint Temperature | NA | |
| Autoignition Temperature | NA | |
| _________ Construction _________ | ______________ | ______________ |
| Placement Cost | Kit (Liquid Digital Valve) | 1 |
| ............................................................. | ......................... | ......................... |
| Deconstruction Tool | Hand Drill | |
| ____________ Power ____________ | ____ Min ____ | ____ Max ____ |
| Power Use | 5W | 5W |
| Heat Generation | 1W | 1W |
| Placement | Dimensions | |||
|---|---|---|---|---|
| Snapping | Small Grid | Length | 1 | |
| Rotation | Any | Height | 1 | |
| Required Support | None | Width | 1 |
| Device Logic Variables | Type | Min | Max | Read | Write | Device Specific Behaviours |
|---|---|---|---|---|---|---|
| Power | bool | 0 | 1 | ✔ | ❌ | |
| Error | bool | 0 | 1 | ✔ | ❌ | |
| Lock | bool | 0 | 1 | ✔ | ✔ | |
| Setting | float | 0 | 100 | ✔ | ✔ | |
| Maximum | int | 100 | 100 | ✔ | ❌ | |
| Ratio | float | 0 | 1 | ✔ | ❌ | |
| On | bool | 0 | 1 | ✔ | ✔ | |
| RequiredPower | float | -1 | 5 | ✔ | ❌ | |
| PrefabHash | int | -517628750 | -517628750 | ✔ | ❌ | |
| ReferenceId | int | ✔ | ❌ |
| Connections | Port | Description |
|---|---|---|
| PipeLiquid Output | 0 | |
| PipeLiquid Input | 1 | |
| Power And Data | 2 |





















