Logistics Devices - Niilo007/Stationeers-Research GitHub Wiki


Logistics Devices


Kit (Stacker)

Kit (Stacker)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 1013244511
Prefab Name ItemKitStacker
______________ Item ______________ ____________ ____________
Stack Size 10
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
Made In Autolathe T1 Autolathe T2
alt text alt text
Time
Energy 500
Iron Fe 10g 10g
Copper Cu 2g 2g

Structure (Stacker)

A stacker is an important part of any automated chute network. The Xigo ProKompile can be set manually or via logic, to make sure items passing through the stacker are maximized for your storage needs.

The ProKompile can stack a wide variety of things such as ingots, as well as splitting stacks into appropriate sizes as needed.

Stacker
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -2020231820
Prefab Name StructureStacker
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Stacker) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
____________ Power ____________ ____ Min ____ ____ Max ____
Power Use 50W 50W
Heat Generation
Placement Dimensions
Snapping Small Grid Length 1
Rotation Horizontal Only Height 2
Required Support None Width 1
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
Power bool 0 1
Mode int 0 1 Mode.
Error bool 0 1
Activate bool 0 1 State of the clear lever.
Lock bool 0 1
Setting int 1 500 Stack size.
On bool 0 1
RequiredPower float -1 50
ClearMemory bool 0
ExportCount int 0
ImportCount int 0
Output int -1 1 Writing 0 or 1 in logic mode outputs 1 stack.
PrefabHash int -2020231820 -2020231820
ReferenceId int
Mode Name Description
0 Automatic Outputs a stack automatically when stack reaches desired size.
1 Logic Outputs 1 stack per activation of Output.
Slot Name Class Icon _______ Slot Name Class Icon
0 Import None 1 Export None
2 Processing None
Logic Slots Type Min Max Read Write Slots Device Specific Behaviours
Occupied bool 0 1 0-2
OccupantHash int 0-2
Quantity 0 0-2
Damage float 0 1 0-2
Class ? int 0 34 0-2
MaxQuantity 0 0-2
PrefabHash int 0-2
SortingClass ? int 0 7 0-2
Connections Port Description
Power And Data 0
Chute Output 1
Chute Input 2

Structure (Stacker)

A stacker is an important part of any automated chute network. The Xigo ProKompile can be set manually or via logic, to make sure items passing through the stacker are maximized for your storage needs.

The ProKompile can stack a wide variety of things such as ingots, as well as splitting stacks into appropriate sizes as needed.

Stacker
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 1585641623
Prefab Name StructureStackerReverse
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Stacker) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
____________ Power ____________ ____ Min ____ ____ Max ____
Power Use 50W 50W
Heat Generation
Placement Dimensions
Snapping Small Grid Length 1
Rotation Horizontal Only Height 2
Required Support None Width 1
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
Power bool 0 1
Mode int 0 1 Mode.
Error bool 0 1
Activate bool 0 1 State of the clear lever.
Lock bool 0 1
Setting int 1 500 Stack size.
On bool 0 1
RequiredPower float -1 50
ClearMemory bool 0
ExportCount int 0
ImportCount int 0
Output int -1 1 Writing 0 or 1 in logic mode outputs 1 stack.
PrefabHash int 1585641623 1585641623
ReferenceId int
Mode Name Description
0 Automatic Outputs a stack automatically when stack reaches desired size.
1 Logic Outputs 1 stack per activation of Output.
Slot Name Class Icon _______ Slot Name Class Icon
0 Import None 1 Export None
2 Processing None
Logic Slots Type Min Max Read Write Slots Device Specific Behaviours
Occupied bool 0 1 0-2
OccupantHash int 0-2
Quantity 0 0-2
Damage float 0 1 0-2
Class ? int 0 34 0-2
MaxQuantity 0 0-2
PrefabHash int 0-2
SortingClass ? int 0 7 0-2
Connections Port Description
Power And Data 0
Chute Output 1
Chute Input 2

Structure (Unloader)

The Xigo Re:Gurge is a handy unit for unloading any items inserted into it, and feeding them into a chute network. For instance, if you add a full Mining Belt, the Re:Gurge will empty a mining belt of its contents, insert them into the chute network, then insert the mining belt itself. A Sorter is recommended to reclaim the mining belt.

Output = 0 exporting the main item
Output = 1 exporting items inside and eventually the main item.

Unloader
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 750118160
Prefab Name StructureUnloader
____________ Durability ____________ ______________ ______________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
_________ Construction _________ ______________ ______________
Placement Cost Kit (Stacker) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
____________ Power ____________ ____ Min ____ ____ Max ____
Power Use 50W 50W
Heat Generation
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 2
Required Support None Width 1
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
Power bool 0 1
Mode int 0 1 Mode.
Error bool 0 1
Lock bool 0 1
On bool 0 1
RequiredPower float -1 50
ClearMemory bool 0
ExportCount int 0
ImportCount int 0
Output int -1 1 0 = Export main item, 1 = Export contents, then main item.
PrefabHash int 750118160 750118160
ReferenceId int
Mode Name Description
0 Automatic Exports contents, and then the main item.
1 Logic Exports 1 item for every activation of Output, Writing 0 export the main item right away.
Slot Name Class Icon _______ Slot Name Class Icon
0 Import None 1 Export None
Logic Slots Type Min Max Read Write Slots Device Specific Behaviours
Occupied bool 0 1 0,1
OccupantHash int 0,1
Quantity 0 0,1
Damage float 0 1 0,1
Class ? int 0 34 0,1
MaxQuantity 0 0,1
PrefabHash int 0,1
SortingClass ? int 0 7 0,1
Connections Port Description
Power And Data 0
Chute Output 1
Chute Input 2

Kit (Sorter)

Kit (Sorter)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 969522478
Prefab Name ItemKitSorter
______________ Item ______________ ____________ ____________
Stack Size 10
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
Made In Autolathe T1 Autolathe T2
alt text alt text
Time
Energy 500
Iron Fe 10g 10g
Gold Au 1g 1g
Copper Cu 5g 5g

Structure (Sorter)

No amount of automation is complete without some way of moving different items to different parts of a system. The Xigo A2B sorter can be programmed via a computer with a Sorter Motherboard to direct various items into different chute networks. Filtered items are always passed out the righthand side of the sorter, while non filtered items continue straight through.

Sorter
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -1009150565
Prefab Name StructureSorter
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Sorter) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
____________ Power ____________ ____ Min ____ ____ Max ____
Power Use 5W 5W
Heat Generation 1W 1W
Placement Dimensions
Snapping Small Grid Length 1
Rotation Horizontal Only Height 2
Required Support None Width 2
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
Power bool 0 1
Mode int 0 2 Mode.
Error bool 0 1
Lock bool 0 1
On bool 0 1
RequiredPower float -1 5
ClearMemory bool 0
ExportCount int 0
ImportCount int 0
Output int -1 1
PrefabHash int -1009150565 -1009150565
ReferenceId int
Mode Name Description
0 Split
1 Filter
2 Logic
Slot Name Class Icon _______ Slot Name Class Icon
0 Import None 1 Export None
2 Export2 None 3 Data Disk Data Disk
Logic Slots Type Min Max Read Write Slots Device Specific Behaviours
Occupied bool 0 1 0-3
OccupantHash int 0-3
Quantity 0 0-3
Damage float 0 1 0-3
Class ? int 0 34 0-3
MaxQuantity 0 0-3
PrefabHash int 0-3
SortingClass ? int 0 7 0-3
Connections Port Description
Chute Output2 0
Chute Input 1
Chute Output 2
Power And Data 3

⚠️ **GitHub.com Fallback** ⚠️