Kit (Logic I/O)
____________ General ____________
____________
____________
Paintable
✔
Nameable
❌
Prefab Hash
1997293610
Prefab Name
ItemKitLogicInputOutput
______________ Item ______________
____________
____________
Stack Size
10
Class
None
0
SortingClass
Kits
1
____________ Durability ____________
____________
____________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
Logic Reader
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-345383640
Prefab Name
StructureLogicReader
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic I/O)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data Input
0
Data Output
1
Power
2
Logic Writer
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-1326019434
Prefab Name
StructureLogicWriter
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic I/O)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data Input
0
Data Output
1
Power
2
Batch Writer
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
1415443359
Prefab Name
StructureLogicBatchWriter
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic I/O)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data Input
0
Data Output
1
Power
2
Logic Mirror
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
2096189278
Prefab Name
StructureLogicMirror
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic I/O)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data Input
0
Data Output
1
Power
2
Slot Reader
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-767867194
Prefab Name
StructureLogicSlotReader
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic I/O)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data Input
0
Data Output
1
Power
2
Batch Reader
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
264413729
Prefab Name
StructureLogicBatchReader
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic I/O)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data Input
0
Data Output
1
Power
2
Structure (Reagent Reader)
Reagent Reader
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-124308857
Prefab Name
StructureLogicReagentReader
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic I/O)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data Input
0
Data Output
1
Power
2
Structure (Batch Slot Reader)
Batch Slot Reader
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
436888930
Prefab Name
StructureLogicBatchSlotReader
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic I/O)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data Input
0
Data Output
1
Power
2
Structure (Logic Writer Switch)
Logic Writer Switch
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-1321250424
Prefab Name
StructureLogicWriterSwitch
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic I/O)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data Input
0
Data Output
1
Power
2
Kit (Logic Memory)
____________ General ____________
____________
____________
Paintable
✔
Nameable
❌
Prefab Hash
-2098214189
Prefab Name
ItemKitLogicMemory
______________ Item ______________
____________
____________
Stack Size
10
Class
None
0
SortingClass
Kits
1
____________ Durability ____________
____________
____________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
The side with the "+" symbol is the "Data, 0" connection and the side with the "-" symbol is the "Data, 1" connection.
Logic Memory
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-851746783
Prefab Name
StructureLogicMemory
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic Memory)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data
0
Data
1
Structure (Logic Hash Generator)
Allows user to select an item, and the device will output the hash of that item.
Logic Hash Generator
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
2077593121
Prefab Name
StructureLogicHashGen
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic Memory)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data
0
Data
1
Kit (Logic Processor)
____________ General ____________
____________
____________
Paintable
✔
Nameable
❌
Prefab Hash
220644373
Prefab Name
ItemKitLogicProcessor
______________ Item ______________
____________
____________
Stack Size
10
Class
None
0
SortingClass
Kits
1
____________ Durability ____________
____________
____________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
The operation can be changed on the fly by other logic, by writing to Mode
.
Logic Math
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
1657691323
Prefab Name
StructureLogicMath
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic Processor)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Mode
Name
Description
0
Add
DI1 + DI2 = DO
1
Subtract
DI1 - DI2 = DO
2
Multiply
DI1 * DI2 = DO
3
Divide
DI1 / DI2 = DO
4
Mod
5
Atan2
6
Pow
DI1DI2 = DO
7
Log
Connections
Port
Description
Data Input
0
Labelled "1" on device.
Data Input
1
Labelled "2" on device.
Data Output
2
Labelled "Out" on device.
Power
3
Structure (Logic Compare)
Logic Compare
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-1489728908
Prefab Name
StructureLogicCompare
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic Processor)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Mode
Name
Description
0
Equals
True If(Input1 = Input2)
1
Greater
True If(Input1 > Input2)
2
Less
True If(Input1 < Input2)
3
NotEquals
True If(Input1 != Input2)
Connections
Port
Description
Data Input
0
Labelled "1" on device.
Data Input
1
Labelled "2" on device.
Data Output
2
Labelled "Out" on device.
Power
3
Truth table:
The state of select decides which input to output.
Input 0
Select
Input 1
Output
0
0
0
0
100
0
0
100
0
1
0
0
0
0
300
0
100
1
0
0
100
0
300
100
0
1
300
300
100
1
300
300
Logic Select
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
1822736084
Prefab Name
StructureLogicSelect
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic Processor)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Data Input
0
Labelled "0" on device.
Data Input
1
Data Output
2
Power
3
Labelled "Select", Doubles as a data input for that pin.
Structure (Logic Min/Max)
Truth tables:
Outputs the smaller or larger of the two, based on Mode
.
Greater:
Input 1
Input 2
Output
0
0
0
100
200
200
-400
200
200
600
400
600
Less:
Input 1
Input 2
Output
0
0
0
100
200
100
-400
200
-400
600
400
400
Logic Min/Max
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
929022276
Prefab Name
StructureLogicMinMax
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic Processor)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Mode
Name
Description
0
Greater
The device starts in this mode.
1
Greater
Output the larger value.
2
Less
Output the smaller value.
Connections
Port
Description
Data Input
0
Labelled "1" on device.
Data Input
1
Labelled "2" on device.
Data Output
2
Power
3
The operation can be changed on the fly by other logic, by writing to Mode
.
Modes:
Rand
Gives a new random value every tick.
Input
Output
Details
0
0
1
0 - 1
Random value between 0 and 1.
-1
-1 - 0
Random value between -1 and 0.
100
0 - 100
Random value between 0 and 100.
Not
Logical Not operator.
Input
Output
Details
0
1
1
0
100
0
Anything above 0 is treated as 1.
-1
1
Negative numbers are treated as 0.
-0.1
1
Negative numbers are treated as 0.
0.1
0
Anything above 0 is treated as 1.
Log
Natural Logarithm.
Input
Output
Details
0
-∞
1
0
2
~0.69315
20
~2.99573
Floor
Round down.
Input
Output
Details
0
0
1
1
2
2
-1
-1
-2
-2
0.1
0
0.8
0
1.1
1
-0.9
-1
-2.3
-3
Ceil
Round up.
Input
Output
Details
0
0
1
1
2
2
-1
-1
-2
-2
0.1
1
0.8
1
1.1
2
-0.9
0
-2.3
-2
Round
Midpoint rounding.
Input
Output
Details
0
0
1
1
2
2
-1
-1
-2
-2
0.1
0
0.8
1
1.1
1
-0.9
-1
-2.3
-2
Exp
Exponential.
Input
Output
Details
0
1
e0
1
~2.718282
e1
2
~7.389056
e2
3
~20.08554
e3
Sin
Sine.
Input
Output
Details
0
0
sin(0), Input is in degrees .
1
~0.0174524
sin(1), Input is in degrees .
2
~0.0348995
sin(2), Input is in degrees .
90
1
sin(90), Input is in degrees .
180
~0
sin(180), Input is in degrees .
360
~0
sin(360), Input is in degrees .
Cos
Cosine.
Input
Output
Details
0
1
cos(0), Input is in degrees .
1
~0.999848
cos(1), Input is in degrees .
2
~0.999391
cos(2), Input is in degrees .
90
~0
cos(90), Input is in degrees .
180
-1
cos(180), Input is in degrees .
360
1
cos(360), Input is in degrees .
Tan
Tangent.
Input
Output
Details
0
0
tan(0), Input is in degrees .
1
~0.017455
tan(1), Input is in degrees .
2
~0.034921
tan(2), Input is in degrees .
89.9
~572.9572
tan(89.9), Input is in degrees .
90
163312...
Gives incorrect value, tan(90) is undefined.
180
~0
tan(180), Input is in degrees .
360
~0
tan(360), Input is in degrees .
Atan
Inverse Tangent.
Input
Output
Details
0
0
atan(0), Output is in degrees .
1
45
atan(1), Output is in degrees .
2
~63.4349
atan(2), Output is in degrees .
-1
-45
atan(-1), Output is in degrees .
Asin
Inverse Sine.
Input
Output
Details
0
0
asin(0), Output is in degrees .
1
90
asin(1), Output is in degrees .
2
NaN
asin(2)
-1
-90
asin(-1), Output is in degrees .
Acos
Inverse Cosine.
Input
Output
Details
0
90
acos(0), Output is in degrees .
1
0
acos(1), Output is in degrees .
2
NaN
acos(2)
-1
180
acos(-1), Output is in degrees .
Abs
Absolute value.
Input
Output
Details
0
0
| 0 |
1
1
| 1 |
2
2
| 2 |
-1
1
| -1 |
-100.1
100.1
| -100.1 |
Sqrt
Square root.
Input
Output
Details
0
0
√0
1
1
√1
2
~1.414214
√2
-1
NaN
√-1
-2
NaN
√-2
Math Unary
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-1160020195
Prefab Name
StructureLogicMathUnary
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic Processor)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Mode
Name
Description
0
Ceil
Round up.
1
Floor
Round down.
2
Abs
Absolute value.
3
Log
Natural logarithm.
4
Exp
Exponent, (e).
5
Round
Midpoint rounding.
6
Rand
Random number between x and 0.
7
Sqrt
Square root.
8
Sin
Sine, Degrees.
9
Cos
Cosine, Degrees.
10
Tan
Tangent, Degrees.
11
Asin
Inverse sine, Degrees.
12
Acos
Inverse cosine, Degrees.
13
Atan
Inverse tangent, Degrees.
14
Not
Logical not.
Connections
Port
Description
Data Input
0
Labelled "In" on device.
Data Output
1
Labelled "Out" on device.
Power
2
A logic device that performs a logical operation on one or more binary inputs that produces a single binary output. An input greater than zero is considered true for operations.
Values greater than 0 are treated as 1.
Values less or equal to 0 are treated as 0.
Does not do bitwise operations.
Logic Gate
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
1942143074
Prefab Name
StructureLogicGate
____________ Durability ____________
______________
______________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
_________ Construction _________
______________
______________
Placement Cost
Kit (Logic Processor)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
10W
10W
Heat Generation
2W
2W
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Mode
Name
Description
0
AND
1
OR
2
XOR
3
NAND
4
NOR
5
XNOR
Connections
Port
Description
Data Input
0
Labelled "1" on device.
Data Input
1
Labelled "2" on device.
Data Output
2
Power
3