The Xigo Freezy Boi wall cooler complements the wall heater, which can only raise the temperature. The wall cooler functions by drawing heat from the surrounding atmosphere and adding that heat into its pipe network.
In order to run the wall cooler properly, you will need to connect pipes to the wall cooler and fill the connected pipe network with any type of gas. The gas's heat capacity and volume will determine how fast it reacts to temperature changes.
EFFICIENCY
The higher the difference in temperature between the gas stored in the pipes and the room, the less efficient the wall cooler will be. So to keep the wall cooler running at an acceptable efficiency you will need to get rid of the heat that accumulates in the pipes connected to it. A common practice would be to run the pipes to the outside and use radiators on the outside section of the pipes to get rid of the heat.
The less efficient the wall cooler, the less power it consumes. It will consume 1010W at max efficiency. The wall cooler can be controlled by logic chips to run when the temperature hits a certain degree.
ERRORS
If the wall cooler is flashing an error then it is missing one of the following:
Pipe connection to the wall cooler.
Gas in the connected pipes, or pressure is too low.
Atmosphere in the surrounding environment or pressure is too low.
For more information about how to control temperatures, consult the temperature control Guides page.
Starts losing cooling power when the temperature differential between the room and the pipe is greater than 100℃.
The Xigo wall heater is a simple device that can be installed on a wall or frame and connected to power. When switched on, it will start heating the surrounding environment. It consumes 1010W of power and can be controlled by logic chips to run when the temperature hits a certain level.