Transformers are used to limit power to protect cables .
Kit (Transformer)
____________ General ____________
____________
____________
Paintable
✔
Nameable
❌
Prefab Hash
665194284
Prefab Name
ItemKitTransformerSmall
______________ Item ______________
____________
____________
Stack Size
5
Class
None
0
SortingClass
Kits
1
____________ Durability ____________
____________
____________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
Structure (Transformer (Small))
Transformers control the maximum power that will flow down a cable subnetwork, to prevent overloading electrical systems. Output on small transformers can be set from 0 to 5000W.
Note that transformers operate as data isolators, preventing data flowing into any network beyond it.
Transformer (Small)
TrS
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-890946730
Prefab Name
StructureTransformerSmall
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Transformer)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
Heat Generation
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
PowerAndData Input
0
Right side.
Power Output
1
Left side.
Structure (Transformer Reversed (Small))
Transformers control the maximum power that will flow down a cable subnetwork, to prevent overloading electrical systems. Output on small transformers can be set from 0 to 5000W.
Note that transformers operate as data isolators, preventing data flowing into any network beyond it.
Transformer Reversed (Small)
TrS
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
1054059374
Prefab Name
StructureTransformerSmallReversed
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Transformer)
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
Heat Generation
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
1
Required Support
Wall
Width
1
Connections
Port
Description
Power Output
0
Right side.
PowerAndData Input
1
Left side.
Structure (Transformer (Medium))
Transformers control the maximum power that will flow down a sub-network of cables, to prevent overloading electrical systems.
Medium transformers are used in larger setups where more than 5000W is required, with output that can be set to a maximum of 25000W.
Note that transformers also operate as data isolators, preventing data flowing into any network beyond it.
Transformer (Medium)
TrM
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-1065725831
Prefab Name
StructureTransformerMedium
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Transformer)
3
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
Heat Generation
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
2
Required Support
Wall
Width
1
Connections
Port
Description
Power Input
0
Left side.
PowerAndData Output
1
Right side.
Structure (Transformer Reversed (Medium))
Transformers control the maximum power that will flow down a sub-network of cables, to prevent overloading electrical systems.
Medium transformers are used in larger setups where more than 5000W is required, with output that can be set to a maximum of 25000W.
Note that transformers also operate as data isolators, preventing data flowing into any network beyond it.
Transformer Reversed (Medium)
TrM
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
833912764
Prefab Name
StructureTransformerMediumReversed
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Transformer)
3
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
Heat Generation
Placement
Dimensions
Snapping
Small Grid
Length
1
Rotation
Any
Height
2
Required Support
Wall
Width
1
Connections
Port
Description
Power Output
0
Left side.
PowerAndData Input
1
Right side.
Kit (Transformer (Large))
Kit Transformer (Large)
____________ General ____________
____________
____________
Paintable
❌
Nameable
❌
Prefab Hash
-453039435
Prefab Name
ItemKitTransformer
______________ Item ______________
____________
____________
Stack Size
1
Class
None
0
SortingClass
Kits
1
____________ Durability ____________
____________
____________
Flashpoint Temperature
100℃
Autoignition Temperature
300℃
Structure (Transformer (Large))
The large Norsec transformer is a critical component of extended electrical networks, controlling the maximum power that will flow down a cable. To prevent overloading, output can be set from 0 to 50,000W.
Note that transformers operate as data isolators, preventing data flowing into any network beyond it.
Transformer (Large)
Tr
____________ General ____________
______________
______________
Paintable
✔
Nameable
✔
Prefab Hash
-1423212473
Prefab Name
StructureTransformer
____________ Durability ____________
______________
______________
Flashpoint Temperature
NA
Autoignition Temperature
NA
_________ Construction _________
______________
______________
Placement Cost
Kit (Transformer (Large))
1
.............................................................
.........................
.........................
Deconstruction Tool
Hand Drill
____________ Power ____________
____ Min ____
____ Max ____
Power Use
0W
0W
Heat Generation
0W
2500W
Placement
Dimensions
Snapping
Small Grid
Length
2
Rotation
Horizontal Only
Height
3
Required Support
None
Width
2
Connections
Port
Description
Data
0
Power Input
1
Power Output
2