Misc - Niilo007/Stationeers-Research GitHub Wiki


Misc


Empty Can

Used for making soups when combined with food in the Basic Packaging Machine or Advanced Packaging Machine. Fairly high in nutrition, canned food does not decay.

Empty Can
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 1013818348
Prefab Name ItemEmptyCan
______________ Item ______________ ____________ ____________
Stack Size 10
Class None 0
SortingClass Default 0
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
Made In Autolathe Autolathe T2
alt text alt text
Time
Energy 70
Steel 1g 1g

Kit (Igniter)

Kit (Igniter)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 890106742
Prefab Name ItemIgniter
______________ Item ______________ ____________ ____________
Stack Size 10
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature NA
Autoignition Temperature NA
Made In Tool Manufactory T1 Tool Manufactory T2
alt text alt text
Time
Energy 500
Copper Cu 3g 3g

Structure (Igniter)

It gets the party started. Especially if that party is an explosive gas mixture.

  • Produces a spark, and adds 500J to the local atmosphere, when activated.
  • Does not require or use any power.
  • Can be activated by hand, or with logic.
  • Easy way to activate it remotely is with a power control circuitboard in a console.
Ignition Source!
Igniter
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 1005491513
Prefab Name StructureIgniter
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Igniter) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support Wall Width 1
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
On bool 0 1 Activate spark.
PrefabHash int 1005491513 1005491513
ReferenceId int
Connections Port Description
Power And Data 0

Kit (Stairs)

Kit (Stairs)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 170878959
Prefab Name ItemKitStairs
______________ Item ______________ ____________ ____________
Stack Size 10
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
Made In Autolathe T1 Autolathe T2
alt text alt text
Time
Energy 500
Iron Fe 15g 15g

Structure (Stairs)

Stairs
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 1405018945
Prefab Name StructureStairs4x2
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Stairs) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
Placement Dimensions
Snapping Large Grid Length
Rotation Horizontal Only Height
Required Support None Width

Structure (Stairs with Rails)

Stairs with Rails
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -1088008720
Prefab Name StructureStairs4x2Rails
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Stairs) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
Placement Dimensions
Snapping Large Grid Length
Rotation Horizontal Only Height
Required Support None Width

Structure (Stairs with Rail (Left))

Stairs with Rail (Left)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 155214029
Prefab Name StructureStairs4x2RailL
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Stairs) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
Placement Dimensions
Snapping Large Grid Length
Rotation Horizontal Only Height
Required Support None Width

Structure (Stairs with Rail (Right))

Stairs with Rail (Right)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -212902482
Prefab Name StructureStairs4x2RailR
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Stairs) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
Placement Dimensions
Snapping Large Grid Length
Rotation Horizontal Only Height
Required Support None Width

Kit (Ladder)

Kit (Ladder)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 489494578
Prefab Name ItemKitLadder
______________ Item ______________ ____________ ____________
Stack Size 10
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
Made In Autolathe T1 Autolathe T2
alt text alt text
Time
Energy 200
Iron Fe 2g 2g

Structure (Ladder)

Ladder
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -415420281
Prefab Name StructureLadder
____________ Durability ____________ ______________ ______________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
_________ Construction _________ ______________ ______________
Placement Cost Kit (Ladder) 1
............................................................. ......................... .........................
Deconstruction Tool Angle Grinder
Placement Dimensions
Snapping Large Grid Length
Rotation Horizontal Only Height
Required Support None Width

Structure (Ladder End)

Ladder End
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 1541734993
Prefab Name StructureLadderEnd
____________ Durability ____________ ______________ ______________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
_________ Construction _________ ______________ ______________
Placement Cost Kit (Ladder) 1
............................................................. ......................... .........................
Deconstruction Tool Angle Grinder
Placement Dimensions
Snapping Large Grid Length
Rotation Horizontal Only Height
Required Support None Width

Kit (Elevator)

Kit (Elevator)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash -945806652
Prefab Name ItemKitElevator
______________ Item ______________ ____________ ____________
Stack Size 5
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
Made In Electronics Printer T1 Electronics Printer T2
alt text alt text
Time
Energy 500
Gold Au 4g 4g
Copper Cu 2g 2g
Steel 2g 2g
Solder 2g 2g

Structure (Elevator Level)

  • All elevator pieces must be connected to power, or the carriage will get stuck.
  • The speed can be increased by writing to ElevatorSpeed.
Elevator Level
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -827912235
Prefab Name StructureElevatorLevelFront
____________ Durability ____________ ______________ ______________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
_________ Construction _________ ______________ ______________
Placement Cost Kit (Elevator) 1
............................................................. ......................... .........................
Deconstruction Tool Angle Grinder
____________ Power ____________ ____ Min ____ ____ Max ____
Power Use 5W 5W
Heat Generation
Placement Dimensions
Snapping Large Grid Length
Rotation Horizontal Only Height
Required Support None Width
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
Power bool 0 1
Open bool 0 1 The state of the door.
Error bool 0 1
Activate bool 0 1 Pressing the call button toggles the value. Value is independent on all level pieces.
Lock bool 0 1
On bool 0 1
RequiredPower int -1 5
ElevatorSpeed float 1.5 20
ElevatorLevel int -1
PrefabHash int -827912235 -827912235
ReferenceId int
Connections Port Description
Elevator 0
Elevator 1
Data 2
Power 3

Elevator

  • Is created with the first placed Elevator Level.
  • Can be painted independently of the levels.
  • If its missing, the elevator has to be re-built.
Elevator
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -110788403
Prefab Name ElevatorCarrage
____________ Durability ____________ ______________ ______________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
_________ Construction _________ ______________ ______________
Placement Cost NA
............................................................. ......................... .........................
Deconstruction Tool Hand Drill

Structure (Elevator Shaft)

  • Used between floors.
    • The carriage doesn't stop at the Elevator Shaft pieces.
  • All elevator pieces must be connected to power, or the carriage will get stuck.
  • The speed can be increased by writing to ElevatorSpeed.
Elevator Shaft
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 826144419
Prefab Name StructureElevatorShaft
____________ Durability ____________ ______________ ______________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
_________ Construction _________ ______________ ______________
Placement Cost Kit (Elevator) 1
............................................................. ......................... .........................
Deconstruction Tool Angle Grinder
____________ Power ____________ ____ Min ____ ____ Max ____
Power Use 5W 5W
Heat Generation
Placement Dimensions
Snapping Large Grid Length
Rotation Horizontal Only Height
Required Support None Width
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
Power bool 0 1
On bool 0 1
RequiredPower int -1 5
ElevatorSpeed float 1.5 20
ElevatorLevel int -1
PrefabHash int 826144419 826144419
ReferenceId int
Connections Port Description
Elevator 0
Elevator 1
Data 2
Power 3

Kit (Cable Fuses)

Kit (Cable Fuses)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 195442047
Prefab Name ItemCableFuse
______________ Item ______________ ____________ ____________
Stack Size 10
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
Made In Electronics Printer T1 Electronics Printer T2
alt text alt text
Time
Energy 100
Iron Fe 5g 5g
Copper Cu 5g 5g

Structure (Fuse (1kW))

Fuse (1kW)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -1103727120
Prefab Name StructureCableFuse1k
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Cable Fuses) 1
............................................................. ......................... .........................
Deconstruction Tool Screwdriver
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support Cable Width 1
Show Inaccessible Data:
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
PrefabHash int -1103727120 -1103727120
ReferenceId int

Structure (Fuse (5kW))

Fuse (5kW)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -631590668
Prefab Name StructureCableFuse5k
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Cable Fuses) 1
............................................................. ......................... .........................
Deconstruction Tool Screwdriver
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support Cable Width 1
Show Inaccessible Data:
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
PrefabHash int -631590668 -631590668
ReferenceId int

Structure (Fuse (50kW))

Fuse (50kW)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -349716617
Prefab Name StructureCableFuse50k
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Cable Fuses) 1
............................................................. ......................... .........................
Deconstruction Tool Screwdriver
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support Cable Width 1
Show Inaccessible Data:
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
PrefabHash int -349716617 -349716617
ReferenceId int

Structure (Fuse (100kW))

Fuse (100kW)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 281380789
Prefab Name StructureCableFuse100k
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Cable Fuses) 1
............................................................. ......................... .........................
Deconstruction Tool Screwdriver
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support Cable Width 1
Show Inaccessible Data:
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
PrefabHash int 281380789 281380789
ReferenceId int

Kit (Pipe Heater Kit (Gas))

Pipe Heater Kit (Gas)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash -1751627006
Prefab Name ItemPipeHeater
______________ Item ______________ ____________ ____________
Stack Size 10
Class None 0
SortingClass Default 0
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
Made In Hydraulic Pipe Bender T1 Hydraulic Pipe Bender T2
alt text alt text
Time
Energy 500
Iron Fe 5g 5g
Gold Au 3g 3g
Copper Cu 3g 3g

Structure (Pipe Heater (Gas))

Adds 1000 joules of heat per tick to the contents of your pipe network.

  • Has 1000W of heating power.
  • Only works if the pipe has at least 6.3kPa of pressure.
    • The heater consumes 10W of idle power in this state.
  • Heats the contents of the pipe up to a maximum of 2227℃.
    • Uses only 10W when at max temperature.
Pipe Heater (Gas)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -419758574
Prefab Name StructurePipeHeater
____________ Durability ____________ ______________ ______________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
_________ Construction _________ ______________ ______________
Placement Cost Pipe Heater Kit (Gas) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
____________ Power ____________ ____ Min ____ ____ Max ____
Power Use 10W 1010W
Heat Generation 2W 2W
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support Pipe Width 1
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
Power bool 0 1
Error bool 0 1
Lock bool 0 1
On bool 0 1
RequiredPower int 0 10
PrefabHash int -419758574 -419758574
ReferenceId int
Connections Port Description
Data 0
Power 1

Kit (Pipe Heater Kit (Liquid))

Pipe Heater Kit (Liquid)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash -248475032
Prefab Name ItemLiquidPipeHeater
______________ Item ______________ ____________ ____________
Stack Size 10
Class None 0
SortingClass Default 0
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
Made In Hydraulic Pipe Bender T1 Hydraulic Pipe Bender T2
alt text alt text
Time
Energy 500
Iron Fe 5g 5g
Gold Au 3g 3g
Copper Cu 3g 3g

Structure (Pipe Heater (Liquid))

Adds 1000 joules of heat per tick to the contents of your pipe network.

  • Has 1000W of heating power.
  • Heats the contents of the pipe up to a maximum of 2227℃.
    • Uses only 10W when at max temperature.
Pipe Heater (Liquid)
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -287495560
Prefab Name StructureLiquidPipeHeater
____________ Durability ____________ ______________ ______________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
_________ Construction _________ ______________ ______________
Placement Cost Pipe Heater Kit (Liquid) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
____________ Power ____________ ____ Min ____ ____ Max ____
Power Use 10W 1010W
Heat Generation 2W 2W
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support Liquid Pipe Width 1
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
Power bool 0 1
Error bool 0 1
Lock bool 0 1
On bool 0 1
RequiredPower int 0 10
PrefabHash int -287495560 -287495560
ReferenceId int
Connections Port Description
Data 0
Power 1

Kit (Pipe Meter)

Kit (Pipe Meter)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 1207939683
Prefab Name ItemPipeMeter
______________ Item ______________ ____________ ____________
Stack Size 5
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature NA
Autoignition Temperature NA
Made In Hydraulic Pipe Bender T1 Hydraulic Pipe Bender T2
alt text alt text
Time
Energy 500
Iron Fe 3g 3g
Copper Cu 2g 2g

Structure (Pipe Meter)

While the Stationeers program has, thus far, inspired little in the way of classical poetry, the following haiku was found etched, ironically, on a piece of pipe wreckage found on Vulcan:
"Humble pipe meter
speaks the truth, transmits pressure
within any pipe"

  • Scale goes from 0MPa to 60.795MPa.
    • 0° - 280°
Pipe Meter
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash -1798362329
Prefab Name StructurePipeMeter
____________ Durability ____________ ______________ ______________
Flashpoint Temperature NA
Autoignition Temperature NA
_________ Construction _________ ______________ ______________
Placement Cost Kit (Pipe Meter) 1
............................................................. ......................... .........................
Deconstruction Tool Wrench
Placement Dimensions
Snapping Small Grid Length 1
Rotation Any Height 1
Required Support Pipe Width 1
Show Inaccessible Data:
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
PrefabHash int -1798362329 -1798362329
ReferenceId int

Kit (Liquid Pipe Meter)


Structure (Liquid Pipe Meter)


Kit (Suit Storage)

Kit (Suit Storage)
____________ General ____________ ____________ ____________
Paintable
Nameable
Prefab Hash 1207939683
Prefab Name ItemPipeMeter
______________ Item ______________ ____________ ____________
Stack Size 5
Class None 0
SortingClass Kits 1
____________ Durability ____________ ____________ ____________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
Made In Hydraulic Pipe Bender T1 Hydraulic Pipe Bender T2
alt text alt text
Time
Energy 500
Iron Fe 15g 15g
Copper Cu 5g 5g
Silver Ag 5g 5g

Structure (Suit Storage)

As tidy as it is useful, the suit storage rack holds an {THING:ItemEvaSuit}, {THING:ItemSpaceHelmet} and a {THING:ItemJetpackBasic}. When powered and connected to {THING:Oxygen} and {THING:Propellant}, it will recharge the suit's batteries, refill the {THING:ItemGasCanisterOxygen} and your {THING:ItemGasFilterNitrogen} {SLOT:GasCanister}. The wastetank will be pumped out to the pipe connected to the waste outlet. All the rack's pipes must be connected or the unit will show an error state, but it will still charge the battery.

  • The waste tank of the suit is emptied with an integrated pump.
  • The air and propellant tanks are directly connected to the pipe connectors.
    • This means external pressure regulation is needed.
  • The suit storage must be powered for the gasses to flow from and to the connected pipes.
Suit Storage
____________ General ____________ ______________ ______________
Paintable
Nameable
Prefab Hash 255034731
Prefab Name StructureSuitStorage
____________ Durability ____________ ______________ ______________
Flashpoint Temperature 100℃
Autoignition Temperature 300℃
_________ Construction _________ ______________ ______________
Placement Cost Kit (Suit Storage) 1
............................................................. ......................... .........................
Deconstruction Tool Hand Drill
____________ Power ____________ ____ Min ____ ____ Max ____
Power Use 50W 50W
Heat Generation
Placement Dimensions
Snapping Small Grid Length 1
Rotation Horizontal Only Height 1
Required Support None Width 4
Device Logic Variables Type Min Max Read Write Device Specific Behaviours
Power bool 0 1
Error bool 0 1
Setting float 0 100
Maximum int 100 100
Ratio float 0 1
On bool 0 1
RequiredPower int -1 50
PrefabHash int 255034731 255034731
ReferenceId int
Slot

Name
Class
Icon

Slot

Name
Class
Icon

Slot

Name
Class
Icon

0 Helmet
Helmet
1 Suit
Suit
2 Back
Back
Logic Slots Type Min Max Read Write Slots Device Specific Behaviours
Occupied bool 0 1 0-2
OccupantHash int 0-2
Quantity 0 0-2
Damage float 0 1 0-2
Pressure float 0 0-2
Charge int 0 0-2
ChargeRatio float 0 1 0-2
Class ? int 0 34 0-2
PressureWaste float 0 1
PressureAir float 0 1
MaxQuantity 0 0-2
PrefabHash int 0-2
Open bool 0 1 0
On bool 0 1 0
Lock bool 0 1 0
SortingClass ? int 0 7 0-2
Connections Port Description
Data 0
Power 1
Pipe Input 2
Pipe Input2 3
Pipe Output 4 Waste tank outlet.

⚠️ **GitHub.com Fallback** ⚠️