Enigma-NG Maintenance Guide

Status: Draft Version: v1.0.0 Associated Hardware Revision: Rev A Last Updated: 2026-04-20

1. Safety Procedures

  • Safety Glow (Amber): If the external Amber LED is lit, the Supercapacitors are discharging (>5.1V). Do not open the machine.
  • Residual Voltage Test: After the Amber LED extinguishes, use a multimeter on the 'SICHERHEITS-PROBE' (V+) and 'ERDE-PROBE' (GND) pads.
  • Touch-Safe Threshold: Only begin work when the multimeter reads <2V.

RTC Battery Safety

The Controller board contains an RTC backup battery (ML2032/CR2032 coin cell).

āš ļø Battery Safety Warning: The RTC backup battery (ML2032/CR2032 coin cell) is a lithium cell. Do not short-circuit, incinerate, disassemble, or expose to temperatures above 60°C. Replace only with the same or equivalent approved type. Dispose of in accordance with local regulations.

  • CR2032 (non-rechargeable): Standard fit. The BAT54 protection diode (D1) must remain in circuit.
  • ML2032 (rechargeable): Only if D1 is removed and the Linux OS dtparam=rtc_bbat_vchg parameter is enabled. See design/Software/Linux_OS/ for software configuration.
  • Service interval: >25 years under normal use. Battery replacement is a service-by-disassembly task — not field-replaceable in situ.

2. Internal Indicators

  • LOGIK-BEREIT (Green): Located on the Power Module near the Controller dock edge. Indicates stable internal logic rails.

3. Power Module Fault Recovery

eFuse Latch-Off Recovery

The Power Module TPS25980 eFuse may latch OFF under the following fault conditions:

  • Overvoltage (OV): Input > 16.9V (OVLO threshold).
  • Overcurrent (OC): Output > 7A (ILIM threshold).
  • Thermal (TCO F1): TCO opens at 72°C board temperature.

Recovery procedure:

  1. Identify and resolve the root fault (e.g., faulty PSE port, overcurrent load, ambient overtemperature).
  2. Remove all input sources (PoE cable, USB-C, battery).
  3. Wait at least 3 seconds for the input bulk capacitors to fully discharge.
  4. Re-apply a single known-good source.
  5. The eFuse will re-enable automatically if the input voltage is within the UVLO-OVLO window and no fault condition is present.

āš ļø If the eFuse repeatedly latches, do not continue cycling power. Diagnose with a bench power supply and current meter before reconnecting the system.

4. Diagnostic Probe Banks

The Controller board features two 2Ɨ10 ENIG Gold diagnostic probe pad banks for real-time bus monitoring during bring-up and fault diagnosis. Connect a logic analyser via a 2Ɨ10 ribbon cable.

Bank-Alpha (PM Dock) — Top-Right of Controller

Monitors the Controller ↔ Power Module dock cluster.

Pin Signal Direction Description
1 5V_MAIN_A PM → CTRL J1 regulated 5V sample
2 5V_MAIN_B PM → CTRL J1 regulated 5V sample
3 3V3_ENIG_A PM → CTRL J1 logic-rail sample
4 3V3_ENIG_B PM → CTRL J1 logic-rail sample
5 VIN_POE_12V CTRL → PM J2 PoE auxiliary feed sample
6 I2C1_SDA Bidir PM telemetry bus
7 I2C1_SCL Bidir PM telemetry bus
8 PM_IO_INT_N PM → CTRL PM expander interrupt
9 PWR_GD PM → CTRL PM rail-health signal
10 ROTOR_EN CTRL → PM PM LDO enable
11 PWR_BUT PM → CTRL CM5 power-button path
12 GND — Signal ground
13 GND — Signal ground
14 GND — Signal ground
15 SPARE — Reserved for future use
16 SPARE — Reserved for future use
17 SPARE — Reserved for future use
18 SPARE — Reserved for future use
19 GND_CHASSIS — Chassis ground reference
20 GND — Signal/power ground return

Bank-Beta (Stator Dock) — Top-Left of Controller

Monitors the Controller ↔ Stator dock cluster.

Pin Signal Direction Description
1 5V_MAIN_J4_1 CTRL → Stator J4 5V blade sample
2 5V_MAIN_J4_2 CTRL → Stator J4 5V blade sample
3 3V3_ENIG_J5_1 CTRL → Stator J5 3V3 blade sample
4 3V3_ENIG_J5_2 CTRL → Stator J5 3V3 blade sample
5 I2C1_SDA Bidir Shared Stator / Settings I²C bus
6 I2C1_SCL Bidir Shared Stator / Settings I²C bus
7 JTAG_TCK JDB → Stator JTAG clock
8 TMS JDB → Stator JTAG mode select
9 TDI JDB → Stator JTAG data in
10 TTD_RETURN Stator → JDB JTAG return from rotor / reflector chain
11 GND_RET_A — Dock return / guard
12 GND_RET_B — Dock return / guard
13 GND_RET_C — Dock return / guard
14 GND_RET_D — Dock return / guard
15 SPARE — Reserved for future use
16 SPARE — Reserved for future use
17 SPARE — Reserved for future use
18 SPARE — Reserved for future use
19 GND_CHASSIS — Chassis ground reference
20 GND — Signal/power ground return