1. Rear Dock Interfaces
The Controller is the fixed motherboard of the enclosure and carries both removable-board docks:
- J1 / J2 / J3 - three TE 10-position connectors to the Power Module
- J4 - Molex EXTreme Guardian HD hybrid connector to the Cypher Board (power-only)
- J5 - Samtec QSS-025 vertical female connector to the Cypher Board (signal-only)
rear edge of Controller
[ J4 ] [ J5 ] [ J1 ] [ J2 ] [ J3 ]
to Cypher to Power Module
2. Controller ↔ Power Module Dock
2.1 J1 - Main Regulated Rails
| Allocation | Notes |
|---|---|
3 x 5V_MAIN |
Primary regulated 5V feed from PM to Controller |
2 x 3V3_ENIG |
Clean logic rail feed from PM to Controller |
5 x GND |
Shared return path |
Connector family: TE 1-1674231-1 (Controller receptacle) ↔ 1123684-7 (PM plug), 10 positions,
2.5 mm pitch, 6 A/contact.
Reference datasheets: TE-1-1674231-1-datasheet.md,
TE-1123684-7-datasheet.md
2.2 J2 - PoE Auxiliary Feed
| Allocation | Notes |
|---|---|
3 x VIN_POE_12V |
Regulated PoE-derived 12V-class auxiliary feed from Controller PoE front-end into PM OR-ing stage |
7 x GND |
Shared return path |
2.3 J3 - Low-Speed Control / Telemetry
| Signal | Direction | Notes |
|---|---|---|
I2C0_SDA |
Bidir | PM-dedicated I²C bus (Bank 0); shared PM telemetry and PM-local GPIO-expander bus |
I2C0_SCL |
Bidir | PM-dedicated I²C bus (Bank 0); shared PM telemetry and PM-local GPIO-expander bus |
PM_IO_INT_N |
PM -> CTRL | Active-low interrupt from PM PCA9534APWR |
PWR_GD |
PM -> CTRL | Direct rail-health telemetry from MCP121T |
ROTOR_EN_N |
CTRL -> PM | Direct 3V3_ENIG LDO enable control |
PWR_BUT_N |
PM -> CTRL | Direct CM5 PMIC power-button path |
LED_PWR_N |
CTRL -> PM | Direct CM5 power-state indication for the SW2 hardware LED logic |
3 x GND |
- | Guards / return path |
3. Controller ↔ Cypher Dock
3.1 J4 - Power-Only Dock (Molex 2195630015 / 2195620015)
Zero signal contacts. See DEC-098.
| Contact type | Allocation | Notes |
|---|---|---|
| Power-pitch (5x, big pins) | 5 x GND |
GND mates first on the larger, more robust contacts |
| Signal-pitch (8x) | 8 x 5V_MAIN |
4.5A/contact rating (Molex 2141130000-PS-000 §4.2) — 36A theoretical capacity |
| Signal-pitch (7x) | 7 x 3V3_ENIG |
4.5A/contact rating — 31.5A theoretical capacity |
Connector family: Molex 2195630015 receptacle on Controller ↔ 2195620015 plug on Cypher.
Reference datasheets: Molex-2195630015-datasheet.md,
Molex-2195630015-drawings.md,
Molex-2195620015-datasheet.md,
Molex-2195620015-drawings.md,
Molex-ExtremeGuardianHD-2141130000-PS-000-specification.md
3.2 J5 - Signal-Only Dock (Samtec QSS-025-01-L-D-A-GP-K / QTS-025-01-L-D-RA-P)
Zero power rails. See DEC-098. 50 contacts: 2 center-GND-bar (1/row) + 24 usable pins/row. Pin
numbering: column Cn, top pin = 2n-1, bottom pin = 2n. Note: the connector's internal ground
wedge runs the full connector length between the top (odd) and bottom (even) pin rows — top/bottom
crosstalk within a column is inherently shielded; the exposure to guard against is column-to-column
(same-row) adjacency, hence the GND separator columns below.
| Top Row Signal | Top Pin# | Bottom Pin# | Bottom Row Signal |
|---|---|---|---|
| GND | 1 | 2 | GND |
| PWM0[0] | 3 | 4 | GND |
| GND | 5 | 6 | PWM0[1] |
| PWM0[2] | 7 | 8 | GND |
| GND | 9 | 10 | PWM0[3] |
| GND | 11 | 12 | GND |
| GND | 13 | 14 | GND |
| GPCLK[0] | 15 | 16 | GPCLK[1] |
| GND | 17 | 18 | GND |
| GND | 19 | 20 | GND |
| USB_D_PLUS | 21 | 22 | USB_D_MINUS |
| GND | 23 | 24 | GND |
| GND (bar) | 25 | 26 | GND (bar) |
| GND | 27 | 28 | GND |
| GND | 29 | 30 | GND |
| I2C1_SDA (Bank 1, Cypher peripherals — existing) | 31 | 32 | I2C1_SCL (Bank 1, existing) |
| GND | 33 | 34 | GND |
| I2C2_SDA (Bank 2, future) | 35 | 36 | I2C2_SCL (Bank 2, future) |
| GND | 37 | 38 | GND |
| I2C3_SDA (Bank 3, future) | 39 | 40 | I2C3_SCL (Bank 3, future) |
| GND | 41 | 42 | GND |
| I2C4_SDA (Bank 4, future) | 43 | 44 | I2C4_SCL (Bank 4, future) |
| GND | 45 | 46 | GND |
| I2C6_SDA (Bank 6, spare/HID-future) | 47 | 48 | I2C6_SCL (Bank 6, spare/HID-future) |
| GND | 49 | 50 | GND |
Note:
I2C0(PM-dedicated bus) is not present on this connector — it is routed exclusively viaJ3to the Power Module (see §2.3). This connector carries onlyI2C1(active) plusI2C2/I2C3/I2C4/I2C6(reserved/NC on the Cypher Board for future expansion). See DR-CTL-13, DEC-099.
Connector family: Samtec QSS-025-01-L-D-A-GP-K (vertical female) on Controller ↔
QTS-025-01-L-D-RA-P (right-angle male) on Cypher.
Reference datasheets: Samtec-QSS-Qualification_test-Report.md,
Samtec-QSS-QTS-RA-Characterisation-Test-Report.md,
Samtec-QSS-QTS-RA-Power-Test-Report.md
J4 and J5 are split strictly by electrical function: J4 carries all power/return (no
signals), J5 carries all signals/GND (no power rails) — see DEC-098.
4. External I/O Placement
right edge of Controller
[ RJ45 + PoE front-end ]
[ USB 3.0 stacked Type-A ]
[ HDMI ]
- The Controller owns the RJ45, Ethernet ESD, magnetics, and PoE PD / ACF front-end.
The PoE front-end passes its regulated auxiliary feed into the Power Module over
J2. J9andJ10are internal-only connectors and are not part of the external I/O edge.J9sits betweenJ5and the Power Module mounting area so it can route by ribbon cable into the future in-lid touchscreen assembly, whileJ10serves the CM5 active-cooler heatsink fan.
5. Placement Summary
rear / dock edge
_______________________________________________________________________
| [J4] [J5] [J9] | (Power Module mounting) |
| (power) (signal) (display) | [J1] [J3] |
| _________________ | [J2] |
| | | |_________________________|
| | CM5 | |
| | Module | |
| | [ Low-Profile ] | [RJ45] |
| | [ Area ] | [USB3] |
| |_________________| [HDMI] |
|_______________________________________________________________________|
left side / internal right side
The Controller is the only board that must be inserted as the enclosure reference part.
The Power Module and Cypher Board then dock into it as mechanically independent service modules.
J4 (power dock, left-middle) and J5 (signal dock, towards centre) are both mounted horizontally,
matching the CM5's own horizontal orientation (right-middle, with Ethernet/USB/HDMI hugging the
right edge). Exact XY placement is finalised at PCB layout time.
6. CM5 Module Carrier (J13, J14, MH13–MH16)
The CM5 Compute Module 5 mounts on the Controller via two Amphenol 10164227-1004A1RLF carrier
sockets (J13, J14) and four SMT standoffs (MH13–MH16).
6.1 J13 and J14 — CM5 Module Carrier Connectors
- Part: Amphenol
10164227-1004A1RLF— CM5 carrier socket, 4.0mm stack height. - Placement: J13 and J14 are placed in the central board region beneath the CM5 module footprint. Both connectors must be positioned to align with the CM5 module edge connector interface per the Raspberry Pi CM5 mechanical drawing. Trace routing and copper fills are permitted in the CM5 shadow area; active or tall components are not (see §6.2 height rule).
- Stack height: 4.0mm from Controller PCB surface to the underside of the CM5 module PCB.
- Cross-ref:
design/Electronics/Controller/Design_Spec.md §2.3; BOM J13, J14.
6.2 MH13–MH16 — CM5 Carrier Standoffs
- Part: Wurth Elektronik
9774040151R— M2.5×4.0mm SMT standoff; four instances. - Function: Mechanical standoffs that set the 4.0mm stack height for J13/J14 and provide rigidity under the CM5 module.
- GND: MH13–MH16 pads shall be connected to
GND— notGND_CHASSIS. Seedesign/Standards/Global_Routing_Spec.mdfor module mounting hole grounding rules. - Placement: Four corners of the CM5 module footprint shadow; exact XY positions TBD at PCB layout, must mirror the CM5 module mechanical reference pattern.
- Component height rule: Maximum installed component height within the CM5 shadow area is 2.0mm above the Controller PCB surface. Only low-profile passive components are permitted beneath the CM5; active ICs, connectors, test points, and exposed via pads are prohibited.
- Cross-ref:
design/Electronics/Controller/Design_Spec.md §2.3; BOM MH13–MH16.
7. PoE ACF Front-End Placement (T1, Q1, Q2, L1, C17, C20)
The PoE ACF Forward front-end occupies the right-edge zone of the board, clustered around the RJ45 magnetics jack and the two PoE ICs (U7 TPS2372-4RGWR, U8 TPS23730RMTR). GbE ESD arrays U5 and U6 are also in this zone.
7.1 Component Summary
| RefDes | Part | Role |
|---|---|---|
| T1 | TDK B82806D0060A120 | ACF Forward PoE PD transformer |
| U7 | TPS2372-4RGWR | PoE PD interface controller |
| U8 | TPS23730RMTR | ACF Forward gate-drive controller |
| Q1 | STD25NF20 | ACF primary switch (GATE_P), DPAK |
| Q2 | STD25NF20 | ACF active clamp switch (GATE_C), DPAK |
| L1 | PA4343.333NLT | 33µH ACF forward output inductor |
| C17 | C0805C223K2RACAUTO | 22nF 200V 0805 ACF primary-side clamp capacitor (Cclamp) |
| C20 (×4) | CGA9N3X7R1E476M230KB | 47µF 25V 2220 ACF output filter capacitors (4× in parallel) |
7.2 Placement Notes
- Zone: Right edge of the Controller PCB directly adjacent to the RJ45 magnetics jack. U7 and U8 shall be placed as close as practical to T1 to minimise the primary-side switching loop area.
- Q1 and Q2 (DPAK): Both DPAK exposed tabs shall be tied to
GNDwith a copper pour and via stitching for thermal dissipation. Q1 and Q2 shall be placed on the primary side of T1 to keep the primary-side switching loop compact. Gate-drive traces from U8 GATE_P to Q1 and from U8 GATE_C to Q2 shall be as short and direct as practical. - T1 solder bridge note: The TDK B82806D0060A120 datasheet permits optional solder bridges between pins 1–2 and between pins 7–8 to parallel primary-side winding pairs for lower resistance. Confirm at schematic capture whether the ACF Forward circuit uses those pins separately before deciding whether to apply the solder bridges in the PCB layout.
- L1 (PA4343.333NLT): 13.5mm × 12.5mm × 6.2mm shielded ferrite SMT inductor. Place on
the secondary side of T1 on the
VIN_POE_12Voutput rail, between T1 and C20. Orient the winding terminals toward T1 to minimise secondary-side loop length. - C17 (0805): Place in the U8 primary-side active-clamp loop between the clamp switch node and GND, within 5mm of U8. 200V rating is required for the primary-side environment.
- C20 (4× 2220): Four CGA9N3X7R1E476M230KB in parallel on
VIN_POE_12Vat the LC filter output. Arrange in a 2×2 grid on the secondary side of L1 with a common pour toVIN_POE_12V. - Cross-ref:
design/Electronics/Controller/Design_Spec.md §6.1; DR-CTL-17 to DR-CTL-22;design/Electronics/Controller/PoE_Power_Analysis.md.
8. Chassis Mounting Holes (MH1–MH4)
Follows GRS §4.3 Pattern A — exact XY positions TBD at PCB layout per GRS §4.2.
- Count: 4× M3 PTH mounting holes (one near each corner)
- Hole diameter: Ø3.2mm (clearance for M3 fastener)
- Net:
GND_CHASSIS— bonded to chassis ground per GRS §4 - BOM: No BOM entry; plain chassis mounting holes with no fitted components
- Cross-ref:
design/Electronics/Controller/Design_Spec.md DR-CTL-18;design/Standards/Global_Routing_Spec.md §4.3