DEC-044 - FDC2114 Internal Oscillator Selected (CLKIN → GND)
- Status: Decided
- Date: 2026-04-26
- Category: Electrical / Component configuration
- Area: Rotor Board, capacitive position sensing, FDC2114 clock source
- Author: Izzyonstage & GitHub Copilot
Summary
The FDC2114 on every Rotor Board uses its internal oscillator as the conversion clock.
The CLKIN pin is tied permanently to GND on the PCB. The CHx_FIN_SEL field in each channel's
SETTLECOUNT register is set to 0b10 (internal oscillator reference).
Problem
The FDC2114 supports two clock sources: an external crystal/oscillator on CLKIN, or the internal ~43.35 MHz oscillator activated when CLKIN is tied to GND. A decision was required on which to use for the Rotor sensing application.
Decision
Use the FDC2114 internal oscillator (CLKIN → GND). This means:
- No external crystal or oscillator component on the Rotor PCB.
CHx_FIN_SEL = 0b10in all active channelSETTLECOUNTregisters.- Conversion reference clock frequency ≈ 43.35 MHz (internal specification).
- CPLD I²C master (VHDL bitstream) configures this field at power-up.
Rationale
- Avoids an external crystal BOM cost and the associated PCB footprint on a space-constrained circular board (Ø92mm with CPLD, FDC2114, sensor electrodes, DIP switches, and connectors).
- The internal oscillator frequency (~43.35 MHz) is well above the ~6.5 MHz nominal resonant frequency of the LC tank (18 µH + 33 pF), satisfying the FDC2114 requirement for the conversion clock to be >4x the sensor resonant frequency.
- Absolute frequency accuracy of the conversion clock is not critical for this application. Gray-code position detection requires only relative threshold crossing detection (presence or absence of an aluminium shroud slot), not absolute frequency measurement.
- Confirmed viable by TI FDC2114 datasheet §8 (internal oscillator specification) and TI FDC2114 application note guidance.
Alternatives Considered
| Alternative | Reason rejected |
|---|---|
| External crystal on CLKIN | Additional BOM line, PCB footprint, and layout complexity; not needed for this sensing application |
| External clock oscillator module | Same objections as crystal; adds cost and board area |
Impact
- Rotor Board PCB: CLKIN tied to GND; no crystal footprint required.
- CPLD VHDL: set
CHx_FIN_SEL = 0b10inSETTLECOUNTregister for all active channels at power-up initialisation. design/Electronics/Rotor/Design_Spec.md: Resonant Front-End Topology subsection updated.design/Software/CPLD_Logic/Rotor_Logic.md: FDC2114 register map documents this setting.
Cross-ref
design/Electronics/Rotor/Design_Spec.md,
design/Software/CPLD_Logic/Rotor_Logic.md,
design/Procedures/Lab_Tests.md (LT-001, LT-002).