DEC-043 - Shared Actuation Module Replaces Direct Controller Servo GPIO
- Status: Decided
- Date: 2026-04-26
- Category: Mechanical / Electrical partitioning
- Area: Controller, Extension, rotor-group turnover, servo actuation
- Author: Izzyonstage & GitHub Copilot
Summary
Replace the former direct Controller-local CM5 servo path with a reusable Actuation Module (AM)
that is hosted both by the Controller and by each Extension. The AM accepts power and a single
active-low ACTUATE_REQUEST line, then performs local homing, one-shot request capture, and servo
PWM generation autonomously.
To support Extension-local actuation power without inventing a second cable family, the
Reflector / Extension harness is widened from 16-pin BHR-16-VUA to 20-pin BHR-20-VUA while
preserving the existing reflector-boundary service bus on pins 1-16 and adding grouped 5V_MAIN
plus returns on pins 17-20.
Problem
The previously active design had two incompatible actuation assumptions:
- the Controller used a direct CM5
SERVO_PWM+SERVO_HOMEinterface - the newly agreed Extension turnover architecture needed a completely local request-driven actuator with no live Controller PWM dependency
That mismatch would have created two different servo-control circuits, two software models, and no clean way to propagate actuation across Extension boundaries.
Decision
-
Adopt one shared Actuation Module PCB everywhere servo stepping is required.
- Controller: one AM for the main depression-bar actuation path.
- Each Extension: one AM for group-boundary carry regeneration.
-
The host/AM electrical contract is reduced to:
- grouped
5V_MAIN,3V3_ENIG,GND - one active-low
ACTUATE_REQUEST - no host-visible
BUSY,HOMED, or fault feedback pins
- grouped
-
The AM owns local servo behaviour.
- power-up homing
- home-switch reading
- request latching / one-shot behaviour
- servo PWM generation
- local LED diagnostics
-
Controller direct servo ownership is retired.
- CM5 GPIO 8 becomes
ACTUATE_REQUEST - the former direct
SERVO_PWM/SERVO_HOMEController path is no longer active
- CM5 GPIO 8 becomes
-
Extension boundaries regenerate carry locally.
- carry remains mechanical within each contiguous 5-rotor group
- at an Extension boundary, the mechanical carry event becomes a local
ACTUATE_REQUEST - the Extension-hosted AM then actuates the next rotor group's first-step mechanism
-
Promote the Reflector / Extension link from 16-pin to 20-pin.
- pins 1-16: unchanged legacy service bus
- pin 17:
5V_MAIN - pin 18:
GND - pin 19:
5V_MAIN - pin 20:
GND
Rationale
- Keeps the Controller and Extension actuation hardware on the same electrical architecture.
- Makes the actuation subsystem field-replaceable and easier to maintain.
- Preserves the mechanical carry principle while still crossing the electrically separated Extension boundary cleanly.
- Avoids overloading the AM host interface with software handshakes the user does not want.
- A reviewed standalone PWM driver such as the PCA9685 is not sufficient by itself because the AM also requires autonomous homing and request sequencing; a small local controller with native PWM is therefore preferred.
Impact
- Add a new
design/Electronics/Actuation_Module/design-doc set. - Update
Controller/Design_Spec.mdandSoftware/Linux_OS/Power_Management.mdto remove the direct CM5 servo model. - Update
Extension/Design_Spec.mdto host the AM and define the local group-boundary actuation role. - Update
Stator,Reflector, andSystem_Architecturedocs for the widened 20-pin Reflector / Extension harness. - Update the mechanical actuation docs so carry is described as mechanical-within-group and Extension-regenerated across group boundaries.
Cross-ref
DEC-038, design/Electronics/Actuation_Module/Design_Spec.md,
design/Electronics/Controller/Design_Spec.md,
design/Electronics/Extension/Design_Spec.md,
design/Mechanical/Rotor_Actuation_Assembly/Design_Spec.md.
QUE-002 supersession note: DEC-043 supersedes the pin count stated in QUE-002 Question 3. QUE-002 Q3 referenced "Stator J10 (16-pin 2x8)" - that was the pre-DEC-043 connector width. J10 is now a 20-pin 2x10 BHR-20-VUA shrouded box header. The mating connectors on Extension (J7/J8) and Reflector (J4) are identical 20-pin 2x10 BHR-20-VUA headers. Standard 20-wire 2.54mm IDC ribbon cable assemblies are suitable for all three; no break-off PCB coupons are required for these links (QUE-002 coupons apply only to Samtec ERF8/ERM8 0.8mm-pitch connectors).