Design Log DEC 029 supercapacitor hold up specification 25f abracon cells 2s4p 20 s at 15w - thepinkmile/Enigma-NG GitHub Wiki

DEC-029 - Supercapacitor Hold-Up Specification: 25F Abracon Cells, 2S4P, ≥20 s at 15W

  • Status: Accepted - 2026-04-14
  • Date: 2026-04-14
  • Category: Electrical
  • Area: Power Module - Supercap Bank, Hold-up Specification
  • Supersedes: DEC-004 (cell reference), DEC-021 (cell capacitance and count)
  • References: DR-PM-07, DR-PM-09, BOM C_SC1-8

Decision

The supercapacitor hold-up minimum requirement is ≥20 seconds at a 15W shutdown load (CM5 typical operating current: 5V x 3A = 15W). The confirmed cell selection (Abracon ADCR-T02R7SA256MB, 25F/2.7V) in a 2S4P (8-cell) arrangement provides ≥33.5 seconds.

⚠️ Cell lock: Cells are Abracon ADCR-T02R7SA256MB, 25F/2.7V in 2S4P (8 cells). Stale values 22F, 33F, 37.5F, 21.7 s, and 24.8 s must never reappear. Any proposed cell or configuration change requires recalculating hold-up against the ≥20 s rule below using the 15W load figure.

Correct Load Figure

⚠️ The CM5 draws 5V x 3A = 15W during typical operation. When a power-loss event occurs, the CM5 is running at this load and continues to draw it throughout the OS shutdown sequence (~10-15 s). Earlier documents used 5W (1A) which significantly overstated margin. All hold-up calculations must use 15W as the minimum design load.

Configuration

Parameter Value
Cell part number Abracon ADCR-T02R7SA256MB
Cell capacitance 25F / 2.7V each
Configuration 2S4P - 8 cells total (C_SC1-C_SC8)
Effective capacitance 50F at 5.4V
Charge voltage (2S) 5.4V
Block footprint 37mm x 77mm (2 columns x 4 rows, 20mm pitch)
Shadow zone 41mm x 81mm

Hold-Up Calculation

Usable energy from a capacitor bank discharged from V_hi to V_lo:

E = 1/2 x C x (V_hi² - V_lo²)

Load power during shutdown: P = 15W (CM5 at 5V x 3A typical).

Hold-up duration: t = E x η / P

Conservative model (pure-buck - LTC3350 loses regulation at V_lo ≈ 4.75V)

Step Calculation Result
Usable energy 1/2 x 50 x (5.4² - 4.75²) 164.9J
Hold-up @ 15W 164.9J / 15W 11.0 s ❌

This model is unrealistic - the LTC3350 is a 4-switch synchronous buck-boost, not a simple buck. It is shown here only to illustrate that relying on the cap voltage staying above the output voltage is not sufficient at this load.

Realistic model (LTC3350 boost mode, V_lo = 2.0V, η = 80%)

The LTC3350 actively boosts the supercap voltage to maintain 5V output in backup mode. Minimum practical V_CAP of ~2.0V protects cells from over-discharge (1.0V/cell for 2S).

Step Calculation Result
Stored energy (V_lo = 2.0V) 1/2 x 50 x (5.4² - 2.0²) 629J
Delivered (η = 80%) 629J x 0.80 503J
Hold-up @ 15W 503J / 15W ≥33.5 s ✔

Sensitivity to LTC3350 efficiency at 15W load

Efficiency Delivered energy Hold-up Pass ≥20 s?
85% 535J 35.6 s ✔
80% 503J 33.5 s ✔
75% 472J 31.5 s ✔
67% 421J 28.1 s ✔
48% (minimum) 302J 20.1 s ✔ (edge)

The ≥20 s rule is satisfied even if converter efficiency degrades to ~48%, which is far below any credible operating point for a synchronous buck-boost at these voltages and currents.

Rationale

  • Why 2S4P (8 cells) and not 2S3P (6 cells)? At 15W, 2S3P (37.5F) delivers 377J at 80% efficiency → 25.2 s. This passes the 20 s rule but leaves only 26% margin. 2S4P (50F) delivers 503J → 33.5 s, a 68% margin, providing meaningful headroom against LTC3350 efficiency variation, higher CM5 loads during bring-up, and supercap aging.
  • Why 15W? The CM5 module draws 5V x 3A under typical operating load. When power is lost, the OS shutdown sequence takes ~10-15 s during which the CM5 continues at near-full load. Using 5W (1A) as the design load significantly understates the required hold-up margin and was an error in DEC-004 and DEC-021.
  • 0.5A PoE charge current (from DEC-004) retained: charge power = 5.4V x 0.5A = 2.7W, unaffected by the cell count increase. Charge time from fully depleted ≈ 9 minutes (100F per series position x 2.7V / 0.5A = 540 s). PoE utilisation calculations in Certification_Evidence are unaffected.

Constraints

  • Do not change the cell MPN, cell count, or configuration without re-running the hold-up calculation at 15W against the ≥20 s rule and updating DR-PM-07, DR-PM-09, and this DEC.
  • LTC3350 CELLS register must remain configured for 2 series cells (CELLS = 0x01).
  • PCB shadow zone: 41mm x 81mm. No traces on L1-L6 within this zone (enclosure rib clearway).