Navigation: Production > Quality control > Quality control orders > Edit QC orders: Register per sample No contents entries on this page Contents Register per sample can be used, if for every unit to be checked, or for every sample the complete checking process is performed subsequently. You can select between "per piece" or "per x pieces" or "per x minutes". The behavior is set up in QC-inspection plan. If in the QC-inspection "per serial number" was stored, for every serial number a separate sample will be created.
In the list all samples for this order are displayed.Window settings and Templates are supported. Samples can or must be released depending on the settings in QC-inspection plan - Release. The Four-eyes principle and the electronic signature are supported. If a reading confirmation of the documents is required, editing is prohibited.
The window is split into the following parts: Ribbon Samples list Release and Valuation Functions
See Quality control orders Quality control order - Item master - Quality control - QC-inspection plan Register per sample Register measurement position Edit measurement position Register per test Register measured values for all samples Documents Transfer
Ribbon Button Meaning Measurement Open selected sample to edit in window Measurement samples Documents Open Documents window to read or edit linked documents See QC-inspection plan - Documents Open order Open the QC-order Button only visible, if the "Samples" window was not opened via QC-order.
Samples list Field Meaning Status (...) An icon indicated the status of the sample Unchecked Number of unchecked measurement positions Faulty Number of measurement positions marked as faulty (with blockage reason) to be released Number of measurement positions to be released Release 1/2 Release ID Last change Data/Time of the last change Blockage reason Stored blockage reason Valuation Stored valuation Release Date / Name / Station Release 2 - Date, Name, Station etc.
Release and Valuation Feld Meaning Release 1 hmtoggle_plus1 Status Release 1
Status is set automatically to "released" after all measured valued have been registered and no errors were reported. open not yet registered all values released all measuring values registered correctly (status automatically set) blocked for all relevant measurement positions a blockage reasons was stored stored, with activated flag "block release" blocked manually - status can be set manually to block the sample independent of measures, and even if no blockage reason was registered
Note: There is no automatic blockage based only on measured values out of allowed range.
Release 2 hmtoggle_plus1 Status Release 2
For samples the Four-eyes principle is supported. Depending on the settings, the status is set automatically or manually. Electronic signature may be necessary.
Behavior is defined in QC-inspection plan - Release
Possibly required prerequisites:
- Release measurement positions completely
- electronic signature
- Valuation
- Reading confirmation for documents Blockage reason hmtoggle_plus1 For incorrect measuring a blockage reason can be stored Setup possible blockage reasons. Only blockage reasons may be selected, which match the QC-inspection plan group or which have no entry there. Furthermore, they need to be visible in the respective area (Order, sample, measurement). Blockage reasons may have further effect. See Blockage reasons
Valuation hmtoggle_plus1 Value the sample Valuation reasons are setup under Valuation
Only valuation reasons may be selected, which match the QC-inspection plan group or which have no entry there. Furthermore, they need to be visible in the respective area (Order, sample, measurement).
Field can be hidden in QC-inspection plan Release-settings or set to mandatory UDF1 ... UDF4 Free definable UDF set up in Configuration wizard
Functions Function Meaning New hmtoggle_plus1 Create another sample This may be necessary, for example, if further samples are required or another QC plan should be used due to differences occurring. The QC plan stored in the "QC plan" tab is always used. The current inspection plan is always used. To use the same inspection plan as for the other samples, use "copy" instead of "new"
Copy hmtoggle_plus1 Copy sample Alternative to "New". The currently selected sample is copied without a measurement result. Use this option if a second sample is needed. In contrast to "new" possible changes in the inspection plan are not taken into account, but values changed in the sample are considered. Change log The Change log displays all changes for this check point
These functions are only available until beas9.0-000-002 Release Sample is marked as released Open Sample is marked as open - in work Block Sample is marked as blocked
Note: Registering measured values and release is performed using the personnel number. A linkage between User and Personnel number is mandatory.
back to Edit QC order