Navigation: Production > Quality control > Quality control orders > Edit QC orders > Register per sample: Measurement samples No contents entries on this page Contents In this window all measured values can be entered for a Sample Window is dynamically adjustable. UDF and Templates can be stored. The authorization for QC-order is required.

After all measured values have been registered, in the sample "release 1" is set to status "released". Depending on the settings, a second release follows, "Release 2", a "batch release", a release of the QC-order or the QC order may be automatically closed. See QC-inspection plan - Release

hmtoggle_plus1 Definition "Sample ok" A sample can consist of several measurement positions. A sample is OK, if

  • for all relevanten measurement positions "OK" and "Release" are active
  • no blockage reason was stored for no measurement position causing "Block release"
  • samples have been set manually to "released"
  • "Release 2" was activated

hmtoggle_plus1 Definition "Sample blocked" A sample is blocked, if

  • the sample was set to "manually blocked"
  • in all measurement positions blockage reasons blockage reasons are stored, in which the ID "Block release" is active

There is no automatic blockage of a sample only due to measurements outside the allowed range.

Configuration of the window Measurement positions list Register measured values Functions

See Quality control orders Quality control order - Item master - Quality control - QC-inspection plan Register per sample Register measurement position Edit measurement position Register per test Register measured values for all samples Documents Transfer

Measurement positions list Field Meaning POS Number of measurement QC-Test Test title Method description Description of method Minimal Allowed minimum Maximal Allowed maximum Target Target value UoM Unit of measurement Sample Sample ID Measurement value Enter the current value or text OK Hooklet, if OK or manually, without entering a value Release Release measurement position? Relevant Hooklet, if relevant for release Blockage reason ID Blockage ID. With right click a blockage reason can be selected. if a valid ID is entered, the blockage reason is filled automatically. Any value can be entered as ID, due to downward compatibility, there is no check . Blockage reason Description of blockage reason. ( Remark)

additional fields can be displayed using window settings

Register measuring values Measured values and attributes can be registered. Blockage reason, valuation and up to 4 additional fields.

Control Enter data on the lower part of the window. Use Cursor up / down and ENTER to jump in the list to the next or previous position.

hmtoggle_plus1 Graphical display of measured values

In the entry area measurement value registration is visualized, similar to scales. On the left the minimum value is indicated, on the right the maximum. Between them, the target value. In the red-green bar the value is visualized: Green area = ok, red area = faulty. The rectangle above shows the current measuring value. If green, the value is within range, if red it is outside.

The graphic is hidden for texts and attributes. If no minimum or maximum values are give, the graphic is hidden. Feld Meaning Measured value hmtoggle_plus1 Enter measured value If the value fits the target (between minimum and maximum), the field is set to "OK". If the Four-eyes principle is disabled, the measurement position is released immediately.

Additionally, in measurement position is stored the employee, the work station and time and date at which the values were registered. OK hmtoggle_plus1 Measured value - Status If a measured value is entered between maximum and minimum, OK is set automatically. If the value is outside the allowed range, the field OK is disabled.

In QC-inspection plan - Measurement position you can store, whether it is possible to set "OK" manually

Attributes Registering attributes ( = no default range of values) the field "OK" is changed manually.

Special case: If minimum and maximum values = 0, this will be interpreted as if no values were set. The maximum value is then 99999, any numeric positive entry will lead to "OK".

Release The measurement position can only be released if "OK" is active.

If in QC-inspection plan the setting "Disable additional release" is enabled, setting the OK field, release is automatically enabled. Release hmtoggle_plus1 Release measurement position Following the Four-eyes principle a second user can release the measurement position. The user, who entered the measured value may not release the measurement position.

Exception: The Four-eyes principle was disabled in the inspection plan. In this case, the measurement position is released automatically, after marked as "OK".

Release not possible:

  • If a blockage reason was stored, which prevents from release. See Blockage reasons
  • Sample has been released already (Release 2)
  • QC-order has been closed already
  • The current user registered the measuring value (Four-eyes principle) Blockage reason hmtoggle_plus1 Blockage reason For each measurement position a blockage reason can be stored

Setup possible blockage reasons. Only blockage reasons may be selected, which match the QC-inspection plan group or which have no entry there. Furthermore, they need to be visible in the respective area (Order, sample, measurement). Blockage reasons may have further effect. See Blockage reasons After selecting a blockage reason "OK" will be disabled, if in the blockage reason "Block release" was activated.

If a measured value or an attribute had been stored already, the entry is checked and of necessary, "OK" is set again. Valuation hmtoggle_plus1 Valuate Measurement position Valuation reasons are setup under Valuation

Only valuation reasons may be selected, which match the QC-inspection plan group or which have no entry there. Furthermore, they need to be visible in the respective area (Order, sample, measurement).

UDF1 ... UDF4 Free definable fields are set up in Configuration wizard

Functions Field Meaning Update hmtoggle_plus1 Entered measuring values, valuations and blockage reasons are saved

Before saving, it is checked, if the sample may be released. The complete release process is performed as defined in Inspection plan - Release Documents Open the Documents screen, in which linked documents are displayed Change hmtoggle_plus1 Change measurement position or create new

Create new or change a measurement position. Button is visible only, if the user has the authority Change QC order. In Terminal-Mode this function is not available.

See Edit measurement position