Retrieve Cache for Nearline Storage - dcm4che/dcm4chee-arc-light GitHub Wiki
This page gives an overview of tests that can be performed if the application has to use a cache storage for paralleling access of objects from storage systems which provides more bandwidth using multiple connections in parallel.
DICOM objects stored on nearline storage systems may be retrieved back to online storage using an independent storage system specifically intended to be used as a retrieve cache.
Below is the basic configuration of nearline and retrieve cache storage systems that need to be done for each of the tests.
- Go to
Configuration
page,Devices
tab and editdcm4chee-arc
device.Edit extension
ofDevice Extension
, nextEdit extension
ofArchive Device
. Create two newChild Object
forStorage Descriptor
with values as shown below.
One may
-
create a LDIF file (e.g.):
dn: dcmStorageID=fs1,dicomDeviceName=dcm4chee-arc,cn=Devices,cn=DICOM Configuration,dc=dcm4che,dc=org objectClass: dcmStorage dcmStorageID: fs1 dcmURI: ${jboss.server.data.url}/fs1/ dcmDigestAlgorithm: MD5 dcmInstanceAvailability: NEARLINE dcmProperty: pathFormat={now,date,yyyy/MM/dd}/{0020000D,hash}/{0020000E,hash}/{00080018,hash} dcmProperty: checkMountFile=NO_MOUNT dcmRetrieveCacheMaxParallel: 10 dcmRetrieveCacheStorageID: retrieve-cache dn: dcmStorageID=retrieve-cache,dicomDeviceName=dcm4chee-arc,cn=Devices,cn=DICOM Configuration,dc=dcm4che,dc=org objectClass: dcmStorage dcmStorageID: retrieve-cache dcmURI: ${jboss.server.data.url}/retrieve-cache/ dcmDigestAlgorithm: MD5 dcmExportStorageID: fs1 dcmProperty: pathFormat={now,date,yyyy/MM/dd}/{0020000D,hash}/{0020000E,hash}/{00080018,hash} dcmProperty: checkMountFile=NO_MOUNT dcmRetrieveCacheMaxParallel: 10
One may refer to Storage Descriptor to understand the description of attributes.
Go to the Control tab on Configuration page in archive UI and reload the configuration.
Enable the logging in Wildfly configuration to DEBUG
mode before starting the tests.
- storescu simulating the external object source (e.g. modality) STORESCU, from which objects are being received
- storescp simulating the external object destination (e.g. workstation) STORESCP, to which received objects are forwarded.
- movescu implements both an SCU for the Query/Retrieve Service Class and an SCP for the Storage Service Class.
- getscu implements SCU for the Query/Retrieve Service Class and an SCP for the Storage Service Class.
- Query Retrieve using C-MOVE and C-GET
- Query Retrieve with Series Metadata
- Query Retrieve after Instance Records Purged
- Retrieve Cache for Export
- Retrieve Cache for RAD-69
- Retrieve Cache for WADO-RS
- Deletion of least recently accessed study from Retrieve Cache
- Deletion of least recently accessed study from Retrieve Cache after Instance Records Purged