22 reference information - wildekek/rdtech-firmware-unisoft GitHub Wiki
Reference Information:
85 22. Reference Information: 22.1. Original Riden Manual https://drive.google.com/drive/folders/1V0l6P1sIJilN1yBOsTO9YGLVdkuO0cX9 22.2. Fuses 1808 SMD Fuses, RD6006 - 10A RD6012 - 20A RD6018 - 25A Note: Image for reference only. Value shown is NOT correct for the RD60xx. Example datasheet
86 22.3. Short Circuit Response Time Testing Test 1: Setup: Unit: RD6018 Load: 5 Ohm (Two 10 W, 10 Ω resistors in parallel) V-SET: 10V I-SET: 10A Test method: Output was turned ON and allowed to settle at 10V, 2A. A short circuit was introduced. Results: Starting from 2 Amps, the current goes up to ~ 27 Amps (perhaps higher) for about 200 microseconds then settles back to around 10 Amps after about 600 microseconds.
87 Test 2: The same test was repeated using a Fluke 80i-110s AC/DC Current Probe in ‘High Current’ mode. Results: The power at the first voltage and current intercept was around 500 Watts. The current peaked at over 100 Amps. (Happily, it is only for about 50 microseconds.) 22.4. Miscellaneous When the internal fan (the one that is on the module itself) is turned on, a fan icon will be displayed. Minimum battery voltage: 500mV