ConferencePapers - upenn/xpl GitHub Wiki

Research Publications, non-peer reviewed:

SPIE 1988

  1. Yaffe MJ, Nishikawa RM, Maidment ADA, Fenster A: Development of a digital mammography system. Medical Imaging II Proceedings of SPIE, Vol 914: 182-188, 1988.

SPIE 1990

  1. Maidment ADA, Yaffe MJ: Scanned-slot digital mammography. Medical Imaging IV: Image Formation. RH Schneider (eds.). Proceedings of SPIE Vol 1231: 316-326, 1990

SPIE 1992

  1. Fahrig R, Maidment ADA, Yaffe MJ: Optimization of peak kilovoltage and spectral shape for digital mammography. Medical Imaging VI: Instrumentation. R Shaw (eds.). Proceedings of SPIE Vol 1651: 74-83, 1992.

SPIE 1993

  1. Maidment ADA, Yaffe MJ, Plewes DB, Mawdsley GE, Soutar IC, Starkoski BG: Imaging performance of a prototype scanned-slot digital mammography system. Physics of Medical Imaging. R Shaw (eds.). Proceedings of SPIE Vol. 1896: 93-103, 1993.

SPIE 1996

  1. Maidment ADA, Albert M, Conant EF, Feig SA: Three-dimensional calcification reconstruction from a limited number of views Medical Imaging 1996: Physics of Medical Imaging. RL Van Metter, J Beutel (eds.). Proceedings of SPIE Vol. 2708: 378-389, 1996.

IWDM 1996: 3rd International Workshop on Digital Mammography (Chicago, IL)

  1. Feig SA, Yaffe MJ, Plewes DB, Maidment ADA, Jong RA: Clinical evaluation of a scanned-slot, full-field digital mammography system. Digital Mammography '96. Doi K, Giger ML, Nishikawa RM and Schmidt RA (eds.). Elsevier Science, Holland, Page: 71-79, 1996.
  2. Maidment ADA, Conant EF, Feig SA, Piccoli CW, Albert M: Three-dimensional analysis of breast calcifications. Digital Mammography '96. K Doi, JL Giger, RM Nishikawa, RA Schmidt (eds.). Elsevier Science, Holland, Page: 245-250, 1996.
  3. Yaffe MJ, Plewes DB, Mawdsley G, Critten J, Feig SA, Maidment ADA, Picarro MF, Tesic M: Full-field digital mammography-system development and technical performance. Digital Mammography '96. K Doi, ML Giger, RM Nishikawa, RA Schmidt (eds.). Elsevier Science, Holland, Page: 125-131, 1996.

Anais do III Fórum Nacional de Ciência e Technologia em Saude (Campos do Jordão, Brazil)

  1. Maidment ADA: Full Field Digital Mammography. Anais do III Fórum Nacional de Ciência e Technologia em Saude. H. Schiabel (eds.). Page: 797-804, 1996.

  2. Ortega HV, Godo MN, Albert M, Maidment ADA, Tartaglino L, Mohamed FB: Fluid flow simulation within brain aneurysms using physiologically accurate data American Society of Mechanical Engineers, Bioengineering Division 35: 285-286, 1997.

CAR '97

  1. Shaber GS, Maidment ADA, Bell J, Jeromin LS, Lee DL, Powell GF: Full Field Digital Projection Radiography System: Principles and Image Evaluation. CAR '97: Computer Assisted Radiology and Surgery. H.U. Lemke, M.W. Vannier and K. Inamura (eds.). Page: 39-45, 1997.

SPIE 1998

  1. Shaber GS, Lee DL, Bell J, Powell G, Maidment ADA: Clinical evaluation of a full field digital projection radiography detector. Medical Imaging 1998: Physics of Medical Imaging. JT Dobbins III, JM Boone (eds.). Proceedings of SPIE 3336: 463-469, 1998.

AIPR

  1. Maidment ADA, Albert A, Conant EF: Three-dimensional imaging of breast calcifications. 26th AIPR Workshop: Exploiting New Image Sources J Sensors, M Selander (eds.). Proceedings of SPIE Vol. 3240: 200-208, March 1998.

IWDM 1998: 4th International Workshop on Digital Mammography (Nijmegen, Netherlands)

  1. Maidment ADA, Albert M, Conant EF, Feig SA: Three-dimensional visualization of breast cancer. Digital Mammography '98. N. Karssemeijer, M. Thijssen, J. Hendricks, L. van Erning (eds.). Kluvier, Holland, Page: 57-60, 1998.
  2. Mawdsley GE, Yaffe MJ, Maidment ADA, Niklason LT, Williams MB, Hemminger BM: Acceptance testing and quality control of digital mammography equipment. Digital Mammography '98. N. Karssemeijer, M. Thijssen, J. Hendricks, and L. van Erning (eds.). Kluvier, Holland, Page: 437-444, 1998.

SPIE Medical Imaging 1999

  1. Hemminger BM, Cole EB, Zong S, Yaffe MJ, Aylward SR, Maidment ADA, Williams MB, Niklason LT, Johnston RE, Pisano ED: Evaluation of digital processing methods for the display of digital mammography. Medical Imaging 1999: Image Display. SK Mun, Y Kim (eds.). Proceedings of SPIE 3658: 382-393, 1999.
  2. Bakic PR, Albert M, Brzakovic D, Maidment ADA: Generation and evaluation of physically inspired synthetic mammograms. Proceedings of the 22nd Annual International Conference of the IEEE 2: 1047-1050, July 2000 doi:10.1109/IEMBS.2000.897906.

IWDM 2000, 5th International Workshop on Digital Mammography (Toronto, Canada)

  1. Maidment ADA, Albert M: Automated Reconstruction of 3-D Calcifications. IWDM 2000 5th International Workshop on Digital Mammography. M.J. Yaffe (eds.). Medical Physics Publishing, Madison WI, Page: 72-80, 2001.

  2. Williams MB, Niklason LT, Yaffe MJ, Mawdsley GE, Maidment ADA, Chakraborty DP, Kimme-Smith CM: Beam Optimization for Digital Mammography. IWDM ## 2000 5th International Workshop on Digital Mammography, MJ Yaffe (eds.). Medical Physics Publishing, Madison WI, Page: 108-119, 2001.

  3. Pisano ED, Cole EB, Major S, Hemminger BM, Muller KE, Johnston RE, Brown ME, Conant EF, Fajardo LL, Feig SA, Yaffe MJ, Williams MB, Niklason LT, Maidment ADA, Braeuning MP, Rosen E, Soo MS, Walsh R, Williford M, Kopans DB, Chakraborty DP, Jong RA, Shumak R, Staiger M, Moore RH: Accuracy of Digital Mammography vs. Screen-Film Mammography in a Diagnostic Mammography Population. IWDM 2000 5th International Workshop on Digital Mammography. M.J. Yaffe (eds.). Medical Physics Publishing, Madison WI, Page: 504-511, 2001.

  4. Bakic PR, Albert M, Brzakovic D, Maidment ADA: Evaluation of a Mammography Simulation. IWDM 2000 5th International Workshop on Digital Mammography. M.J. Yaffe (eds.). Medical Physics Publishing, Madison WI, Page: 681-687, 2001.

  5. Bakic PR, Albert M, Maidment ADA, Reljin B: Experiment with 3-D Mammography and their Possible Applications in Telemammography. Annals of the Academy of Studenica 4: 67-69 2001.

SPIE 2002

  1. Bakic PR, Albert M, Maidment ADA: Dose requirements in stereoradiography Medical Imaging 2002: Physics of Medical Imaging. Antonuk LE, Yaffe MJ (eds.). Proceedings of SPIE 4682: 126-137, 2002.

IWDM 2002, 6th International Workshop on Digital Mammography (Bremen, Germany)

  1. Bakic PR, Albert M, Maidment ADA: Evaluation of Breast Ductal Networks Using Ramification Matrices. IWDM 2002, 6th International Workshop on Digital Mammography. H-O Peitgen (eds.). Springer-Verlag, Berlin, Page: 249-252, 2002.
  2. Maidment ADA, Bakic PR, Albert M: Is Stereomammography Possible Without Increased Dose. IWDM 2002, 6th International Workshop on Digital Mammography. H-O Peitgen (eds.). Springer-Verlag, Berlin, Page: 510-516, 2003.

SPIE 2003

  1. Bakic PR, Albert M, Maidment ADA: 2-AFC observer study of digital stereomammography Medical Imaging 2003: Image Perception, Observer Performance, and Technology Assessment. Chakraborty DP, Krupinski EA (eds.). Proceedings of SPIE Vol. 5034: 1-9, 2003.

  2. Maidment ADA, Albert M, Bunch PC, Cunningham IA, Dobbins III JT, Gagne RM, Nishikawa RM, Van Metter RL, Wagner RF: Standardization of NPS measurement: Interim report of AAPM TG16. Medical Imaging 2003: Physics of Medical Imaging. Yaffe MJ, Antonuk LE (eds.). Proceedings of SPIE 5030(I): 523-532, 2003.

  3. Richard FJP, Bakić PR, Maidment ADA: Non-rigid registration of mammograms obtained with variable breast compression: A phantom study Lecture Notes in Computer Science, 2717: 281-290, 2003.

  4. Bakic PR, Albert M, Maidment ADA, and Reljin B: Topological Analysis of Breast Ductal Network ETRAN 2003: 47th Serbo-Montenegrin (Yugoslav) Conference of Electronics, Telecommunications, Computers, Automation, and Nuclear Engineering Page: 157-160, 2003.

SPIE 2004

  1. Maidment ADA, Karasick T, Bakic PR, Albert M: 2-AFC observer study of shape and contrast discrimination in digital stereomammography. Medical Imaging 2004: Image Perception, Observer Performance, and Technology Assessment, DP Chakraborty, MP Eckstein (eds.). Proceedings of SPIE 5372: 62-71, 2004.

SPIE 2005

  1. Albert M, Carton AK, Maidment ADA: Camera calibration for synthetic digital tomography Medical Imaging 2005: Physics of Medical Imaging. MJ Flynn (eds.). Proceedings of SPIE 5745: 1291-1299, 2005.
  2. Maidment ADA, Albert M, Thunberg S, Adelöw L, Blom O, Egerström J, Eklund M, Francke T, Jordung U, Kristoffersson T, Lindman K, Lindqvist L, Marchal D, Olla H, Penton E, Rantanen J, Solokov S, Ullberg C, Weber N: Evaluation of a photon-counting breast tomosynthesis imaging system. Medical Imaging 2005: Physics of Medical Imaging. MJ Flynn (eds.). Proceedings of SPIE 5745: 572-582, 2005.
  3. Hoeschen C, Tischenko O, Dance DR, Hunt RA, Maidment ADA, Bakic PR: Testing a wavelet-based noise reduction method using computer-simulated mammograms Medical Imaging 2005: Physics of Medical Imaging. MJ Flynn (eds.). Proceedings of SPIE 5745: 969-978, 2005.
  4. Kao YH, Albert M, Carton AK, Bosmans H, Maidment ADA: A software tool for measurement of the modulation transfer function. Medical Imaging 2005: Physics of Medical Imaging. MJ Flynn (eds.). Proceedings of SPIE 5745: 1199-1208, 2005.

IWDM 2024, 7th International Workshop on Digital Mammography (Chapel Hill, NC)

  1. Maidment ADA, Albert M, Kao YH: Determination of Calcification Composition. Proceedings of the 7th International Workshop on Digital Mammography. ED Pisano (eds.). The University of North Carolina, Biomedical Research Imaging Center, Chapel Hill, NC, Page: 364-369, 2005.

  2. Thunberg S, Maidment ADA, Adelow K: Tomosynthesis with a Multi-line Photon Counting Camera. Proceedings of the 7th International Workshop on Digital Mammography. ED Pisano (eds.). The University of North Carolina, Biomedical Research Imaging Center, Chapel Hill, NC, Page: 459-465, 2005.

  3. Maidment ADA, Albert M, Bakic PR, Karasick T: 2-AFC Observer Study of Shape and Contrast Discrimination in Digital Stereomammography. Proceedings of the 7th International Workshop on Digital Mammography. ED Pisano (eds.). The University of North Carolina, Biomedical Research Imaging Center, Chapel Hill, NC, Page: 474-483, 2005.

  4. Bakic PR, Richard FJP, Maidment ADA: Effect of Breast Compression on Registration of Successive Mammograms. Proceedings of the 7th International Workshop on Digital Mammography. The University of North Carolina, Biomedical Research Imaging Center, Chapel Hill, NC, E.T. Pisano (eds.). Page: 691-697, 2005.

  5. Maidment ADA, Carton AK, Chen S, Conant EF, Schnall M: Quantification of contrast-enhanced digital breast tomosynthesis International Journal of Computer Assisted Radiology and Surgery 1 (SUPPL. 7): 12-14, 2006.

  6. Kontos D, Megalooikonomou V, Javadi A, Bakic PR, Maidment ADA: Classification of galactograms using fractal properties of the breast ductal network. 3rd IEEE International Symposium on Biomedical Imaging: From Nano to Macro - Proceedings Page: 1324-1327, 2006.

SPIE 2006

  1. Maidment ADA, Ullberg C, Lindman K, Adelöw L, Egerström J, Eklund M, Francke T, Jordung U, Kristoffersson T, Lindqvist L, Marchal D, Olla H, Penton E, Rantanen J, Solokov S, Weber N, Westerberg H: Evaluation of a photon-counting breast tomosynthesis imaging system Medical Imaging 2006: Physics of Medical Imaging. MJ Flynn, J Hsieh (eds.). Proceedings of SPIE 6142: 61420B, 2006.
  2. Carton AK, Li J, Albert M, Chen S, Maidment ADA: Quantification for contrast-enhanced digital breast tomosynthesis. Medical Imaging 2006: Physics of Medical Imaging. MJ Flynn, J Hsieh (eds.). Proceedings of SPIE 6142: 61420D, 2006.
  3. Megalooikonomou V, Kontos D, Danglemaier J, Javadi A, Bakic PR, Maidment ADA: A representation and classification scheme for tree-like structures in medical images: An application on branching pattern analysis of ductal trees in x-ray galactograms Medical Imaging 2006: Image Processing. JM Reinhardt, JPW Pluim (eds.). Proceedings of SPIE 6144: 61441H, 2006.
  4. Bakic PR, Rosen MA, Maidment ADA: Comparison of breast ductal branching pattern classification using x-ray galactograms and MR autogalactograms. Medical Imaging 2006: Image Processing, JM Reinhardt, JPW Pluim (eds.). Proceedings of SPIE 6144: 614425, 2006.

IWDM 2006, 8th International Workshop on Digital Mammography

  1. Bakic PR, Richard FJP, Maidment ADA: 2D-to-3D x-ray breast image registration Lecture Notes in Computer Science. 4057: 84-91, 2006.
  2. Carton AK, Li J, Chen S, Conant EF, Maidment ADA: Optimization of contrast-enhanced digital breast tomosynthesis Lecture Notes in Computer Science. S Astley, M Brady, C Rose, R Zwiggelaar (eds.). 4046: 183-189, 2006.
  3. Maidment ADA, Ullberg C, Francke T, Lindqvist L, Sokolov S, Lindman K, Adelow L, Sunden P: Clinical evaluation of a photon-counting tomosynthesis mammography system Lecture Notes in Computer Science. S Astley, M Brady, C Rose, R Zwiggelaar (eds.). 4046: 144-151, 2006.
  4. Williams MB, Raghunathan P, Seibert A, Kwan A, Lo J, Samei E, Fajardo L, Maidment ADA, Yaffe MJ, Bloomquist, A: Beam optimization for digital mammography - II Lecture Notes in Computer Science. S Astley, M Brady, C Rose, R Zwiggelaar (eds.). 4046: 273-280, 2006.
  5. Bakic PR, Richard FJP, Maidment ADA: Registration of mammograms and breast tomosynthesis images Lecture Notes in Computer Science. S Astley, M Brady, C Rose, R Zwiggelaar (eds.). 4046: 498-503, 2006.
  6. Bakic PR, Kontos D, Megalooikonomou V, Rosen MA, Maidment ADA: Comparison of methods for classification of breast ductal branching patterns. Lecture Notes in Computer Science. S Astley, M Brady, C Rose, R Zwiggelaar (eds.). 4046: 634-641, 2006.

SPIE 2007

  1. Carton AK, Lindman K, Ullberg C, Francke T, Maidment ADA: Dual-energy subtraction for contrast-enhanced digital breast tomosynthesis Medical Imaging 2007: Physics of Medical Imaging. J Hsieh, MJ Flynn (eds.). Proceedings of SPIE 6510: 651007, 2007.
  2. Kontos D, Bakic PR, Maidment ADA: Analysis of parenchymal texture properties in breast tomosynthesis images Medical Imaging 2007: Computer-Aided Diagnosis, ML Giger, N Karssemeijer (eds.). Proceedings of SPIE 6514: 651417, 2007.
  3. Bakic PR, Kontos D, Zhang C, Yaffe MJ, Maidment ADA: Analysis of percent density estimates from digital breast tomosynthesis projection images Medical Imaging 2007: Computer-Aided Diagnosis. ML Giger, N Karssemeijer (eds.). Proceedings of SPIE 6514: 651424, 2007.
  4. Bakic PR, Vujovic N, Maidment ADA: Establishing correspondence in mammograms and tomosynthesis projections Medical Imaging 2007: Computer-Aided Diagnosis. ML Giger, N Karssemeijer (eds.). Proceedings of SPIE 6514: 651425, 2007.

SPIE 2008

  1. Bakic PR, Kontos D, Carton AK, Maidment ADA: Breast percent density estimation from 3D reconstructed digital breast tomosynthesis images Medical Imaging 2008: Physics of Medical Imaging. J Hsieh, E Samei (eds.). Proceedings of SPIE 6913: 691318, 2008.
  2. Kontos D, Bakic PR, Maidment ADA: Texture in digital breast tomosynthesis: A comparison between mammographic and tomographic characterization of parenchymal properties Medical Imaging 2008: Computer-Aided Diagnosis. ML Giger, N Karssemeijer (eds.). Proceedings of SPIE 6915: 69150A, 2008.
  3. Zhang C, Bakic PR, Maidment ADA: Development of an anthropomorphic breast software phantom based on region growing algorithm Medical Imaging 2008: Visualization, Image-Guided Procedures, and Modeling. MI Miga, KR Cleary (eds.). Proceedings of SPIE 6918: 69180V, 2008.
  4. Ruiter NV, Zhang C, Bakic PR, Carton AK, Kuo J, Maidment ADA: Simulation of tomosynthesis images based on an anthropomorphic software breast tissue phantom Medical Imaging 2008: Visualization, Image-Guided Procedures, and Modeling. MI Miga, KR Cleary (eds.). Proceedings of SPIE 6918: 69182I, 2008.

IWDM 2008, 9th International Workshop on Digital Mammography

  1. Barnathan M, Zhang J, Kontos D, Bakic PR, Maidment ADA, Megalooikonomou V: Analyzing tree-like structures in biomedical images based on texture and branching: An application to breast imaging Lecture Notes in Computer Science. EA Krupinski (eds.). 5116: 25-32, 2008.

  2. Carton AK, Ullberg C, Lindman K, Francke T, Maidment ADA: Optimization of a dual-energy contrast-enhanced technique for a photon counting digital breast tomosynthesis system. Lecture Notes in Computer Science. EA Krupinski (eds.). 5116: 116-123, 2008.

  3. Carton AK, Currivan JA, Conant EF, Maidment ADA: Temporal subtraction versus dual-energy contrast-enhanced digital breast tomosynthesis: A pilot study Lecture Notes in Computer Science . EA Krupinski (eds.). 5116: 166-173, 2008.

  4. Kontos D, Zhang C, Ruiter N, Bakic PR, Maidment ADA: Evaluating the effect of tomosynthesis acquisition parameters on image texture: A study based on an anthropomorphic breast tissue software model Lecture Notes in Computer Science. EA Krupinski (eds.). 5116: 491-498, 2008.

  5. Zhang C, Bakic PR, Xia S, Liu F, Maidment ADA: Evaluation of 3D breast surface reconstruction accuracy using non-contact scanner images: A phantom study . Lecture Notes in Computer Science, EA Krupinski (eds.). 5116: 585-592, 2008.

  6. Bakic PR, Kontos D, Troxel AB, Maidment ADA: Comparison of breast percent density estimated from digital mammograms and central reconstructed tomosynthesis slice images Lecture Notes in Computer Science. EA Krupinski (eds.). 5116: 674-680, 2008.

  7. Kontos D, Bakic PR, Troxel AB, Conant EF, Maidment ADA: Digital breast tomosynthesis parenchymal texture analysis for breast cancer risk estimation: A preliminary study Lecture Notes in Computer Science, EA Krupinski (eds.). 5116: 681-688, 2008.

  8. Kontos D, Berger R, Bakic PR, Maidment ADA: Breast tissue classification in digital breast tomosynthesis images using texture features: A feasibility study Medical Imaging 2009: Computer-Aided Diagnosis, N Karssemeijer, ML Giger (eds.). Proceedings of SPIE 7260: 726024, 2009.

ISBI 2009

  1. Ling H, Barnathan M, Megalooikonomou V, Bakic PR, Maidment ADA: Probabilistic branching node detection using hybrid local features Proceedings - 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2009 Page: 233-236, 2009.

SPIE 2010

  1. Carton, AK, Bakic, P, Ullberg, C, Maidment, ADA: Development of a 3D high-resolution physical anthropomorphic breast phantom Medical Imaging 2010: Physics of Medical Imaging. E Samei, NJ Pelc (eds.). Proceedings of SPIE 7622: 762206, 2010.
  2. Bakic PR, Ng S, Ringer P, Carton AK, Conant EF, Maidment ADA: Validation and optimization of digital breast tomosynthesis reconstruction using an anthropomorphic software breast phantom Medical Imaging 2010: Physics of Medical Imaging. E Samei, NJ Pelc (eds.). Proceedings of SPIE 7622: 76220F, 2010.
  3. Acciavatti RJ, Maidment ADA: An analytical model of NPS and DQE comparing photon counting and energy integrating detectors. Medical Imaging 2010: Physics of Medical Imaging. E Samei, NJ Pelc (eds.). Proceedings of SPIE 7622: 76220I, 2010. doi: 10.1117/12.845310.
  4. Berger, R, Carton, AK, Maidment, ADA, Kontos, D: FFDM image quality assessment using computerized image texture analysis Medical Imaging 2010: Physics of Medical Imaging. E Samei, NJ Pelc (eds.). Proceedings of SPIE 7622: 76220I, 2010.
  5. Lee D, Maidment ADA: Removal of trapped charge in selenium detectors Medical Imaging 2010: Physics of Medical Imaging, E Samei, NJ Pelc (eds.). Proceedings of SPIE 7622: 762218, 2010.
  6. Bradley LR, Carton AK, Maidment ADA: Angular dependence of mammographic dosimeters in digital breast tomosynthesis Medical Imaging 2010: Physics of Medical Imaging. E Samei, NJ Pelc (eds.). Proceedings of SPIE 7622: 76225L, 2010.
  7. Kontos D, Xing Y, Bakic PR, Conant EF, Maidment ADA: A comparative study of volumetric breast density estimation in digital mammography and magnetic resonance imaging: results from a high-risk population Medical Imaging 2010: Computer-Aided Diagnosis. N Karssemeijer, RM Summers (eds.). Proceedings of SPIE 7624: 762409, 2010.

IWDM 2010, 10th International Workshop of Digital Mammography

  1. Bakic PR, Ringer P, Kuo J, Ng S, Maidment ADA: Analysis of geometric accuracy in digital breast tomosynthesis reconstruction Lecture Notes in Computer Science, J Marti, A Oliver, J Freixent and R Marti (eds.). 6136: 62-69, 2010.
  2. Conant EF, Li D, Gavenonis S, Bakic PR, Carton AK, Zhang C, Maidment ADA, Kontos D: A comparative study of the inter-reader variability of breast percent density estimation in digital mammography: Potential effect of reader's training and clinical experience. Lecture Notes in Computer Science, J Marti, A Oliver, J Freixent and R Marti (eds.). 6136: 114-120, 2010.
  3. Kontos D, Bakic PR, Acciavatti RJ, Conant EF, Maidment ADA: A comparative study of volumetric and area-based breast density estimation in digital mammography: Results from a screening population Lecture Notes in Computer Science. J Marti, A Oliver, J Freixent and R Marti (eds.). 6136: 378-385, 2010. doi: 10.1007/978-3-642-13666-5_51
  4. Acciavatti RJ, Maidment ADA: Calculation of OTF, NPS, and DQE for oblique x-ray incidence on turbid granular phosphors. Lecture Notes in Computer Science, J Marti, A Oliver, J Freixent and R Marti (eds.). Page: 436-443, 2010. doi: 10.1007/978-3-642-13666-5_59
  5. Bakic PR, Lau B, Carton AK, Reiser I, Maidment ADA, Nishikawa RM: An anthropomorphic software breast phantom for tomosynthesis simulation: Power spectrum analysis of phantom projections Lecture Notes in Computer Science, J Marti, A Oliver, J Freixent and R Marti (eds.). 6136: 452-458, 2010.
  6. Cheng E, Xie N, Ling H, Bakic PR, Maidment ADA, Megalooikonomou V: Mammographic image classification using histogram intersection. 7th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2010 - Proceedings Page: 197-200, 2010. ISBI 2010
  7. Nuzhnaya, T., Barnathan, M., Ling, H., Megalooikonomou, V., Bakic, P.R., Maidment, A.D.A.: Probabilistic branching node detection using AdaBoost and hybrid local features 7th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2010 - Proceedings Page: 221-224, 2010.
  8. Zheng Y, Maidment ADA, Gee JC: Accurate registration of dynamic contrast-enhanced breast MR images with robust estimation and linear programming. 2010 7th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2010 - Proceedings Page: 536-539, 2010. AIP
  9. Ikejimba LC, Kontos D, Maidment ADA: Breast cancer risk estimation using parenchymal texture analysis in digital breast tomosynthesis AIP Conference Proceedings 1280: 163-175, 2010.

SPIE 2011

  1. Bakic PR, Li C, West E, Sak M, Gavenonis SC, Duric N, Maidment ADA: Comparison of 3D and 2D breast density estimation from synthetic ultrasound tomography images and digital mammograms of anthropomorphic software breast phantoms Medical Imaging 2011: Physics of Medical Imaging. NJ Pelc, E Samei, RM Nishikawa (eds.). Proceedings of SPIE 7961: 79610Z, 2011.

  2. Kuo J, Ringer PA, Fallows SG, Bakic PR, Maidment ADA, Ng S: Dynamic reconstruction and rendering of 3D tomosynthesis images Medical Imaging 2011: Physics of Medical Imaging. NJ Pelc, E Samei, RM Nishikawa (eds.). Proceedings of SPIE 7961: 796116, 2011.

  3. Acciavatti RJ, Maidment ADA: Investigating the potential for super-resolution in digital breast tomosynthesis Medical Imaging 2011: Physics of Medical Imaging NJ Pelc, E Samei, RM Nishikawa (eds.). Proceedings of SPIE 7961: 79615K, 2011. doi: 10.1117/12.878845

  4. Cheng E, Ling H, Bakic PR, Maidment ADA, Megalooikonomou V: Automatic detection of regions of interest in mammographic images Medical Imaging 2011: Image Processing. BM Dawant, DR Haynor (eds.). Proceedings of SPIE 7962: 79623J, 2011.

  5. Daye D, Bobo E, Baumann B, Ioannou A, Conant EF, Maidment ADA, Kontos D: Mammographic parenchymal texture as an imaging marker of hormonal activity: A comparative study between pre- and post-menopausal women Medical Imaging 2011: Computer-Aided Diagnosis RM Summers, B van Ginneken (eds.). Proceedings of SPIE 7963: 79631N, 2011.

  6. Cheng E, McLaughlin S, Megalooikonomou V, Bakic PR, Maidment ADA, Ling H: Learning-based vessel segmentation in mammographic images Proceedings - 2011 1st IEEE International Conference on Healthcare Informatics, Imaging and Systems Biology, HISB 2011 Page: 315-322, 2011.

  7. Skoura A, Megalooikonomou V, Bakic PR, Maidment ADA: Classifying ductal tree structures using topological descriptors of branching. IFIP Advances in Information and Communication Technology. L.S. Iliadis, I. Maglogiannis, H. Papadopoulos (eds.). IFIP - International Federation for Information Processing, 364 (PART 2): 455-463, 2011 12th International Conference, EANN 2011 and 7th IFIP WG 12.5 International Conference, AIAI 2011, Corfu, Greece, September 15-18, 2011

SPIE 2012

  1. Acciavatti RJ, Maidment ADA: Optimization of continuous tube motion and step-and-shoot motion in digital breast tomosynthesis systems with patient motion Medical Imaging 2012: Physics of Medical Imaging. NJ Pelc, RM Nishikawa, BR Whiting (eds.). Proceedings of SPIE 8313: 831306, 2012. doi: 10.1117/12.911016
  2. Chui JH, Pokrajac DD, Maidment ADA, Bakic PR: Roadmap for efficient parallelization of breast anatomy simulation Medical Imaging 2012: Physics of Medical Imaging. NJ Pelc, RM Nishikawa, BR Whiting (eds.). Proceedings of SPIE 8313: 83134T, 2012.
  3. Contijoch F, Lynch JM, Pokrajac DD, Maidment ADA, Bakic PR: Shape analysis of simulated breast anatomical structures Medical Imaging 2012: Physics of Medical Imaging. NJ Pelc, RM Nishikawa, BR Whiting (eds.). Proceedings of SPIE 8313: 83134U, 2012.
  4. Chen F, Pokrajac DD, Shi X, Liu F, Maidment ADA, Bakic PR: Partial volume simulation in software breast phantoms Medical Imaging 2012: Physics of Medical Imaging. NJ Pelc, RM Nishikawa, BR Whiting (eds.). Proceedings of SPIE 8313: 83134U, 2012.

IWDM 2012: 11th International Workshop on Digital Mammography

  1. Gavenonis S, Lau K, Karunamuni R, Zhang Y, Ren B, Ruth C, Maidment ADA: Initial experience with dual-energy contrast-enhanced digital breast tomosynthesis in the characterization of breast cancer Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics). ADA Maidment, PR Bakic, S Gavenonis (eds.). 7361: 32-39, 2012. doi: 10.1007/978-3-642-31271-7_5
  2. Chen F, Pokrajac DD, Shi X, Liu F, Maidment ADA, Bakic PR: Simulation of three material partial volume averaging in a software breast phantom Lecture Notes in Computer Science. ADA Maidment, PR Bakic, S Gavenonis (eds.). 7361: 149-156, 2012.
  3. Vieira MAC, Bakic PR, Maidment ADA, Schiabel H, Mascarenhas NDA: Filtering of poisson noise in digital mammography using local statistics and adaptive wiener filter Lecture Notes in Computer Science. ADA Maidment, PR Bakic, S Gavenonis (eds.). 7361: 268-275, 2012.
  4. Brunner CC, Acciavatti RJ, Bakic PR, Maidment ADA, Williams MB, Kaczmarek R, Chakrabarti K: Evaluation of various mammography phantoms for image quality assessment in digital breast tomosynthesis Lecture Notes in Computer Science. ADA Maidment, PR Bakic, S Gavenonis (eds.). 7361: 284-291, 2012. doi: 10.1007/978-3-642-31271-7_37
  5. Marchessoux C, Avanaki AN, Bakic PR, Kimpe TRL, Maidment ADA: Effects of medical display luminance, contrast and temporal compensation on CHO detection performance at various browsing speeds and on digital breast tomosynthesis images Lecture Notes in Computer Science. ADA Maidment, PR Bakic, S Gavenonis (eds.). 7361: 292-299, 2012.
  6. Acciavatti RJ, Maidment ADA: Proposing an acquisition geometry that optimizes super-resolution in digital breast tomosynthesis Lecture Notes in Computer Science. ADA Maidment, PR Bakic, S Gavenonis (eds.). 7361: 386-393, 2012. doi: 10.1007/978-3-642-31271-7_50
  7. Karunamuni R, al Zaki A, Popov AV, JDelikatny EJ, Gavenonis, S, Tsourkas A, Maidment ADA: An examination of silver as a radiographic contrast agent in dual-energy breast x-ray imaging Lecture Notes in Computer Science . ADA Maidment, PR Bakic, S Gavenonis (eds.). 7361: 418-425, 2012.
  8. Chui JH, Pokrajac DD, Maidment ADA, Bakic PR: Towards breast anatomy simulation using GPUs Lecture Notes in Computer Science. ADA Maidment, PR Bakic, S Gavenonis (eds.). 7361: 506-513, 2012.
  9. Wang Y, Keller BM, Zheng Y, Acciavatti RJ, Gee JC, Maidment ADA, Kontos D: A phantom study for assessing the effect of different digital detectors on mammographic texture features Lecture Notes in Computer Science. ADA Maidment, PR Bakic, S Gavenonis (eds.). 7361: 604-610, 2012. doi: 10.1007/978-3-642-31271-7_78
  10. Acciavatti RJ, Mein SB, Maidment ADA: Investigating oblique reconstructions with super-resolution in digital breast tomosynthesis Lecture Notes in Computer Science. ADA Maidment, PR Bakic, S Gavenonis (eds.). 7361: 737-744, 2012. doi: 10.1007/978-3-642-31271-7_95

SPIE 2013

  1. Acciavatti RJ, Bakic PR, Maidment ADA: Proposing a new velocity profile for continuous x-ray tube motion in digital breast tomosynthesis. Medical Imaging 2013: Physics of Medical Imaging. RM Nishikawa, BR Whiting (eds.). Proceedings of SPIE 8668: 86680F, 2013. doi: 10.1117/12.2007764

  2. Vieira M, Bakic PR, Maidment ADA: Effect of denoising on the quality of reconstructed images in digital breast tomosynthesis. Medical Imaging 2013: Physics of Medical Imaging. RM Nishikawa, BR Whiting (eds.). Proceedings of SPIE 8668 : 86680C, 2013.

  3. Chui JH, Zeng R, Pokrajac DD, Park S, Myers KJ, Maidment ADA, Bakic PR: Two methods for simulation of dense tissue distribution in software breast phantoms. Medical Imaging 2013: Physics of Medical Imaging. RM Nishikawa, BR Whiting (eds.). Proceedings of SPIE 8668: 86680M, 2013.

  4. Bakic PR, Keller BM, Zheng Y, WangY, Gee JC, Kontos D, Maidment ADA: Testing realism of software breast phantoms: texture analysis of synthetic mammograms. Medical Imaging 2013: Physics of Medical Imaging. RM Nishikawa, BR Whiting (eds.). Proceedings of SPIE 8668 : 866824, 2013.

  5. Jing H, Keller BM, Choi JY, Crescenzi R, Conant EF, Maidment ADA, Kontos D: Dependence of radiation dose on area and volumetric mammographic breast density estimation. Medical Imaging 2013: Physics of Medical Imaging. RM Nishikawa, BR Whiting, Proceedings of SPIE 8668 : 866827, 2013.

  6. Chen F, Zheng P, Xu P, Maidment ADA, Bakic PR, Pokrajac DD, Liu F, Shi X: Breast image registration by using non-linear local affine transformation. Medical Imaging 2013: Physics of Medical Imaging. RM Nishikawa, BR Whiting (eds.). Proceedings of SPIE 8668: 86684J, 2013.

  7. Karunamuni R, Maidment ADA: Quantification of a silver contrast agent in dual-energy breast x-ray imaging. Medical Imaging 2013: Physics of Medical Imaging. RM Nishikawa, BR Whiting (eds.). Proceedings of SPIE 8668: 866862, 2013.

  8. Karunamuni R, Kanamaluru S, Lau K, Gavenonis S, Bakic PR, Maidment ADA: Exploring the relationship between SDNR and detectability in dual-energy breast x-ray imaging. Medical Imaging 2013: Physics of Medical Imaging. RM Nishikawa, BR Whiting (eds.). Proceedings of SPIE 8668 : 866863, 2013. doi: 10.1117/12.2008114

  9. Wang Y, Keller BM, Zheng Y, Acciavatti RJ, Gee JC, Maidment ADA, Kontos, D: Texture feature standardization in digital mammography for improving generalizability across devices Medical Imaging 2013: Computer-Aided Diagnosis. CL Novak, S Aylward (eds.). Proceedings of SPIE 8670: 867026, 2013. doi: 10.1117/12.2008149

  10. Avanaki A, Espig K, Marchessoux C, Krupinski EA, Bakic PR, Kimpe T, Maidment ADA: Integration of spatio-temporal contrast sensitivity with a multi-slice channelized Hotelling observer. Medical Imaging 2013: Image Perception, Observer Performance, and Technology Assessment. CK Abbey, CR Mello-Thoms (eds.). Proceedings of SPIE 8673: 86730H, 2013.

  11. Vieira, M.A., Bakic, P.R., Maidment, A.D.A., Mascarenhas, N.: Investigating Poisson Noise Filtering in Digital Breast Tomosynthesis. In Proc. of Computer Vision Workshop (WVC 2013) 2013. MIPS XV: Medical Image Perception Society

  12. Avanaki, A., Espig, K., Marchessoux, C., Bakic, P.R., Maidment, A.D.A., Kimpe, T.: On modeling the effects of display contrast and luminance in a spatio-temporal numerical observer. In Proc. Medical Image Perception Society (MIPS) XV Conference 2013.

SPIE 2014

  1. Acciavatti, R.J., Chang, A., Woodbridge, L., Maidment, A.D.A.: Optimizing the acquisition geometry for digital breast tomosynthesis using the Defrise phantom. In Physics of Medical Imaging, Proc. SPIE 9033. B. Whiting, C. Hoeschen, D. Kontos (eds.). 2014. doi: 10.1117/12.2043988
  2. Lau, K.C., Roth, S., Maidment, A.D.A.: 2D and 3D registration methods for dual-energy contrast-enhanced digital breast tomosynthesis In Physics of Medical Imaging, Proc. SPIE 9033. B. Whiting, C. Hoeschen, D. Kontos (eds.). 2014. doi: 10.1117/12.2044080
  3. Shankla, V., Pokrajac, D.D., Weinstein, S.P., DeLeo, M., Tuite, C., Roth, R., Conant, E.F., Maidment, A.D.A., Bakic, P.R.: Automatic Insertion of Simulated Microcalcification Clusters in a Software Breast Phantom. In Physics of Medical Imaging, Proc. SPIE 9033. B. Whiting, C. Hoeschen, D. Kontos (eds.). 2014.
  4. Eckstein, M.P., Boone, J.M.,Abbey, C.K., Bakic, P.R., Pokrajac, D.D., Maidment, A.D.A., : Non-Gaussian Statistical Properties of Virtual Breast Phantoms. In Image Perception, Observer Performance, and Technology Assessment, Proc. SPIE 9037. C. Mello-Thoms, M. Kupinski (eds.). 2014.
  5. Avanaki, A., Espig, K.S., Maidment, A.D.A., Marchessoux, C., Bakic, P.R., Kimpe, T.: Development and Evaluation of a 3D Model Observer with Nonlinear Spatiotemporal Contrast Sensitivity In Image Perception, Observer Performance, and Technology Assessment Proc. SPIE 9037. C. Mello-Thoms, M. Kupinski (eds.). 2014.

IWDM 2014: 12th International Workshop on Digital Mammography

  1. Maidment, A.D.A.: Virtual Clinical Trials for the Assessment of Novel Breast Screening Modalities. Lecture Notes in Computer Science, Breast Imaging (IWDM). Fujita H., Hara T., Muramatsu, C. (eds.). Springer-Verlag Berlin Heidelberg 8539: 1-8, 2014.
  2. Bakic, P.R., Pokrajac, D.D., De Caro, R., Maidment, A.D.A.: Realistic Simulation of Breast Tissue Microstructure in Software Anthropomorphic Phantoms. Breast Imaging (IWDM), Lecture Notes in Computer Science. Fujita H., Hara T., Muramatsu, C. (eds.). Springer-Verlag Berlin Heidelberg 8539: 348-355, 2014.
  3. Cockmartin, L., Bakic, P.R., Bosmans, H., Maidment, A.D.A., Gall, H., Zerhouni, M., Marshall, N.W. : Power Spectrum Analysis of an Anthropomorphic Breast Phantom Compared to Patient Data in 2D Digital Mammography and Breast Tomosynthesis. Breast Imaging (IWDM), Lecture Notes in Computer Science. Fujita H., Hara T., Muramatsu, C. (eds.). Springer-Verlag Berlin Heidelberg 8539: 423-429, 2014.
  4. Bakic, P.R., Pokrajac, D.D., Thomas, M., Skoura, A., Nuzhnaya, T., Megalooikonomou, V., Keller, B., Zheng, Y., Kontos, D., Gee, J.C., Cardenosa, G., Maidment, A.D.A.: Correlation Between Topological Descriptors of the Breast Ductal Network from Clinical Galactograms and Texture Features of Corresponding Mammograms. Breast Imaging (IWDM), Lecture Notes in Computer Science. Fujita H., Hara T., Muramatsu, C. (eds.). Springer-Verlag Berlin Heidelberg 8539: 658-665, 2014.
  5. Avanaki, A.R.N., Espig, K.S., Xthona, A., Kimpe, T.R.L., Bakic, P.R., Maidment, A.D.A.: It is Hard to See a Needle in a Haystack: Modeling Contrast Masking Effect in a Numerical Observer. Breast Imaging (IWDM), Lecture Notes in Computer Science. Fujita H., Hara T., Muramatsu, C. (eds.). Springer-Verlag Berlin Heidelberg 8539: 723-730, 2014.

SPIE 2015

  1. Lau, K.C., Lee, H.M., Singh, T., Maidment, A.D.A.: Segmentation Methods for Breast Vasculature in Dual-Energy Contrast-Enhanced Digital Breast Tomosynthesis. Physics of Medical Imaging, Proc. SPIE C. Hoeschen, D. Kontos, T. Flohr (eds.). 9412(941227), 2015. doi: 10.1117/12.2081031
  2. Vieira MAC, Nunes PF, Oliveira HCR, Borges LR, Bakic PR, Acciavatti RJ, Barufaldi B, Maidment ADA. Feasibility Study of Dose Reduction in Digital Breast Tomosynthesis Using Non-Local Denoising Algorithms. In Physics of Medical Imaging, C. Hoeschen, D. Kontos, T. Flohr (eds.). Proc. SPIE. 9412, 944122C, 2015. doi: 10.1117/12.2082398
  3. Acciavatti, R.J., Ray, S., Keller, B.M., Maidment, A.D.A., Conant, E.F.: A comparative analysis of 2D and 3D CAD for calcifications in digital breast tomosynthesis. Computer-Aided Diagnosis, Proc. SPIE L. Hadjiiski, G. Tourassi (eds.). 9414(94140N), 2015. doi: 10.1117/12.2082082
  4. Barufaldi, B., Lau, K.C., Schiabel, H., Maidment, A.D.A.: Computational assessment of mammography accreditation phantom images and correlation with human observer analysis. Image Perception, Observer Performance, and Technology Assessment, Proc. SPIE C. Mello-Thoms, M. Kupinski (eds.). 9416(941606), 2015. doi: 10.1117/12.2082074
  5. Avanaki, A., Espig, K.S., Xthona, A., Kimpe, T.R.L., Bakic, P.R., Maidment, A.D.A.: On anthropomorphic decision making in a model observer In Image Perception, Observer Performance, and Technology Assessment Proc. SPIE. C. Mello-Thoms, M. Kupinski (eds.). 9416(941610), 2015.
  6. Oliveira, H.C.R., Borges, L., Nunes, P.F., Bakic, P.R., Maidment, A.D.A., Vieira, M.A.C. : Use of Wavelet Multiresolution Analysis to Reduce Radiation Dose in Digital Mammography. 28th IEEE Int'l Symposium on Computer Based Medical Systems Page: 33-37 2015.
  7. Acciavatti RJ, Maidment ADA: Modeling acquisition geometries with improved super resolution in digital breast tomosynthesis. Physics of Medical Imaging, Proc. SPIE. D. Kontos, T. Flohr (eds.). 9783, 2016 doi: 10.1117/12.2216440
  8. Ali R. N. Avanaki, Kathryn S. Espig, Eddie Knippel, Tom R. L. Kimpe, Albert Xthona, Andrew D. A. Maidment: Location- and lesion-dependent estimation of background tissue complexity for anthropomorphic model observer Medical Imaging 2016: Image Perception, Observer Performance, and Technology Assessment, Proc. of SPIE Craig K. Abbey and Matthew A. Kupinski (eds.). 9787(97870A-13), 2016 doi: 10.1117/12.2217612.

SPIE 2016

  1. Lau KC, Kwon YJ, Aziz MK, Acciavatti RJ, Maidment ADA. Estimating breast thickness for dual-energy subtraction in contrast-enhanced digital mammography using calibration phantoms. Medical Imaging 2016: Physics of Medical Imaging, Kontos D., T. Flohr (eds.). Proc. SPIE 9783, 978307 (2016). doi: 10.1117/12.2214748
  2. Pokrajac DD, Imran A, Maidment ADA, Bakic PR: Estimation of adipose compartment volumes in CT images of a mastectomy specimen. Physics of Medical Imaging, Proc. SPIE D. Kontos, T. Flohr (eds.). 9783, 2016.
  3. Vent TL, Acciavatti RJ, Kwon YJ, Maidment ADA: Quantification of resolution in multiplanar reconstructions for digital breast tomosynthesis. Physics of Medical Imaging, Proc. SPIE. D. Kontos, T. Flohr (eds.). 9783, 2016. doi: 10.1117/12.2216260
  4. Pokrajac DD, Maidment ADA, Bakic PR: Reduction of artifacts in computer simulation of breast Cooper's ligaments. Physics of Medical Imaging, Proc. SPIE. D. Kontos, T. Flohr (eds.). 9783, 2016.
  5. Maria A.Z. Sousa, Karem D. Marcomini, Predrag R. Bakic, Andrew D.A. Maidment and Homero Schiabela: Observer study to evaluate the simulation of mammographic calcification clusters Medical Imaging 2016: Image Perception, Observer Performance, and Technology Assessment, Proc. of SPIE Craig K. Abbey and Matthew A. Kupinski (eds.). 9787(9787), 2016 doi: 10.1117/12.2217257.
  6. Oliveira HCR, Barufaldi B, Borges LR, Gabarda S, Bakic PR, Maidment ADA, Vieira MAC, Schiabel H: Validation of no-reference image quality index for the assessment of digital mammographic images. Image Perception, Observer Performance, and Technology Assessment, Proc. SPIE. C. Abbey, M. Kupinski (eds.). 9787, 978713, 2016.

IWDM 2016, 13th International Workshop

  1. Conant EF, Oustimov A, Zuckerman SP,McDonald KS, Weinstein SP, Maidment ADA, Barufaldi B, Synnestvedt M, Schnall M. Summary of Outcomes from Consecutive Years of Tomosynthesis Screening at an American Academic Institution. IWDM 2016. A. Tingberg et al (eds.). Lecture Notes in Computer Science, Vol. 9699: 20-24, 2016 doi: 10.1007/978-3-319-41546-8_3.
  2. Barufaldi B, Borges LR, Vieira MAC, Gabarda S, Maidment ADA, Bakic PR, Pokrajac DD, and Schiabel H: The Effect of Breast Composition on a No-reference Anisotropic Quality Index for Digital Mammography. IWDM 2016 A. Tingberg et al. (Eds.): Lecture Notes in Computer Science, Vol. 9699: 226-233, 2016 doi: 10.1007/978-3-319-41546-8_30.
  3. Lucas R. Borges, Igor Guerrero, Predrag R. Bakic, Andrew D.A. Maidment, Homero Schiabel, and Marcelo A.C. Vieira: Simulation of Dose Reduction in Digital Breast Tomosynthesis IWDM 2016 A. Tingberg et al. (eds.). Springer International Publishing Switzerland 9699: 343-350, 2016 doi: 10.1007/978-3-319-41546-8_43.
  4. Predrag R. Bakic, David D. Pokrajac, Rebecca Batiste, Michael D. Feldman,and Andrew D.A. Maidment: Simulation of Breast Anatomy: Bridging the Radiology-Pathology Scale Gap IWDM 2016 A. Tingberg et al. (eds.). Springer International Publishing Switzerland, 9699: 478-485, 2016 doi: 10.1007/978-3-319-41546-8_60.
  5. Predrag R. Bakic, Kyle J. Myers, Stephen J. Glick, Andrew D.A. Maidment,and The members of AAPM Task Group : Virtual Tools for the Evaluation of Breast Imaging: State-of-the Science and Future Directions IWDM 2016 A. Tingberg et al. (eds.). Springer International Publishing Switzerland 9699: 518-524, 2016 doi: 10.1007/978-3-319-41546-8_65.
  6. Lau KC, Acciavatti RJ, Maidment ADA: Estimating Breast Thickness for Dual-Energy Subtraction in Contrast-Enhanced Digital Mammography: A Theoretical Model. IWDM 2016. A. Tingberg et al. (eds.). Lecture Notes in Computer Science, Vol. 9699: 593-600, 2016 doi: 10.1007/978-3-319-41546-8_74.

SPIE 2017

  1. Raymond J. Acciavatti ; William Mannherz ; Margaret Nolan and Andrew D. A. Maidment: An alternate design for the Defrise phantom to quantify resolution in digital breast tomosynthesis. Medical Imaging 2017: Physics of Medical Imaging conference. Thomas G. Flohr; Joseph Y. Lo; Taly Gilat Schmidt (eds.). 10132 (1013223-10), February 2017 doi:10.1117/12.2253986.
  2. Bakic, P, Pokrajac, D, Maidment, AD: Computer simulation of the breast subcutaneous and retromammary tissue for use in virtual clinical trials. Medical Imaging 2017: Physics of Medical Imaging, Proc. SPIE 10132, 2017.
  3. Borges, L, Bakic, P, Maidment, AD, Vieira, MA: Metal artifact reduction using a patch-based reconstruction for digital breast tomosynthesis. Medical Imaging 2017: Physics of Medical Imaging, Proc. SPIE 10132, 2017.
  4. Borges, L, Bakic, P,Foi, A, Maidment, AD, Vieira, MA: Pipeline for effective denoising of digital mammography and digital breast tomosynthesis. Medical Imaging 2017: Physics of Medical Imaging, Proc. SPIE 10132, 2017.
  5. Abdullah-Al-Zubaer Imran; Predrag R. Bakic; Andrew D. A. Maidment and David D. Pokrajac: Optimization of the simulation parameters for improving realism in anthropomorphic breast phantoms. Medical Imaging 2017: Physics of Medical Imaging Proc. SPIE. Thomas G. Flohr; Joseph Y. Lo; Taly Gilat Schmidt (eds.). 10132(1013257 ), February 2017 doi:10.1117/12.2253903.
  6. Ferris, W, Vent, T, Maidment, T, Acciavatti, R, Wurtele, D, Maidment, AD: Geometric calibration for a next-generation digital breast tomosynthesis system. Medical Imaging 2017: Physics of Medical Imaging, Proc. SPIE 10132, 101324C, 2017. doi: 10.1117/12.2255301.
  7. Kuperavage, A, Imran, AAZ, Bakic, P, Maidment, A, Pokrajac, D: Validation of Cooper's ligament thickness in software breast phantoms. Medical Imaging 2017: Physics of Medical Imaging, Proc. SPIE 10132, 2017.
  8. Maidment, T, Vent, T, Ferris, W, Wurtele, D, Acciavatti, R, Maidment, AD: Comparing the imaging performance of computed super resolution and magnification tomosynthesis. Medical Imaging 2017: Physics of Medical Imaging, Proc. SPIE 10132, 1013222, 2017. doi: 10.1117/12.2255564
  9. Maria A. Z. Sousa ; Predrag R. Bakic ; Homero Schiabel and Andrew D. A. Maidment: A comparison of methods to evaluate gray scale response of tomosynthesis systems using a software breast phantom. Medical Imaging 2017: Image Perception, Observer Performance, and Technology Assessment. Matthew A. Kupinski; Robert M. Nishikawa (eds.). 10136(101360J), February 2017 doi:10.1117/12.2255554.
  10. Bruno Barufaldi ; Lucas R. Borges ; Predrag R. Bakic ; Marcelo A. C. Vieira ; Homero Schiabel and Andrew D. A. Maidment: Assessment of the automatic exposure control performance in digital mammography using a no-reference anisotropic quality index. Medical Imaging 2017: Image Perception, Observer Performance, and Technology Assessment. Matthew A. Kupinski, Robert M. Nishikawa (eds.). 10136 (101360U), 2017 doi:org/10.1117/12.2255629.

SPIE 2018

  1. Acciavatti R, Rodríguez-Ruiz A, Vent TL, Bakic PR, Reiser I, Sechopoulos I, Maidment ADA: Analysis of volume overestimation artifacts in the breast outline segmentation in tomosynthesis. Medical Imaging 2018: Physics of Medical Imaging, Proc. SPIE 10573: 1057359, March 2018 doi: 10.1117/12.2293253. Epub 2018 Mar 9. PMID: 38327670
  2. Bakic PR, Barufaldi B, Higginbotham D, Weinstein S, Avanaki A, Espig K, Xthona A, Kimpe TR, Maidment, ADA: Virtual clinical trial of lesion detection in digital mammography and digital breast tomosynthesis. Medical Imaging 2018: Physics of Medical Imaging, Proc. SPIE 10573: 1057306, March 2018 doi: 10.1117/12.2294934.
  3. Barufaldi B, Higginbotham D, Bakic PR, Maidment ADA: OpenVCT: a GPU-accelerated virtual clinical trial pipeline for mammography and digital breast tomosynthesis. Medical Imaging 2018: Physics of Medical Imaging, Proc. SPIE 10573: 1057358, March 2018 doi: 10.1117/12.2294935.
  4. Borges LR, Bakic PR, Maidment ADA, Vieira MAC: Restored low-dose digital breast tomosynthesis: a perception study. Medical Imaging 2018: Image Perception, Observer Performance, and Technology Assessment, Proc. SPIE 10577: 1057705, March 2018 doi: 10.1117/12.2293252.
  5. Brito FA, Borges LR, Guerrero I, Bakic PR, Maidment ADA, Vieira MAC: Application of neural networks to model the signal-dependent noise of a digital breast tomosynthesis unit. Medical Imaging 2018: Physics of Medical Imaging, Proc. SPIE 10573: 105730J, March 2018 doi: 10.1117/12.2293659.
  6. Choi CJ, Vent TL, Acciavatti RJ, Maidment ADA: Geometric calibration for a next-generation digital breast tomosynthesis system using virtual line segments. Medical Imaging 2018: Physics of Medical Imaging, Proc. SPIE 10573: 105730D, March 2018 doi: 10.1117/12.2294634.
  7. Eben JE, Vent TL, Choi CJ, Yarrabothula S, Chai L, Nolan M, Kobe E, Acciavatti RJ, Maidment ADA: Development of a next generation tomosynthesis system. Medical Imaging 2018: Physics of Medical Imaging, Proc. SPIE 10573: 105735Q, March 2018 doi: 10.1117/12.2294931.
  8. Lago MA, Abbey CK, Barufaldi B, Bakic PR, Weinstein SP, Maidment ADA, Eckstein MP: Interactions of lesion detectability and size across single-slice DBT and 3D DBT. Medical Imaging 2018: Image Perception, Observer Performance, and Technology Assessment, Proc. SPIE 10577: 105770X, March 2018 doi: 10.1117/12.2293873.
  9. Pokrajac DD, Petkovic MD, Maidment ADA, Kuperavage A, Bakic PR: Improved simulation of Cooper ligaments in breast phantoms. Medical Imaging 2018: Physics of Medical Imaging, Proc. SPIE 10573: 1057309, March 2018 doi: 10.1117/12.2294927.

IWDM 2018: 14th International Workshop on Breast Imaging

  1. Acciavatti RJ, Hsieh MK, Gastounioti A, Hu Y, Chen J, Maidment ADA, Kontos D: Validation of the textural realism of a 3D anthropomorphic phantom for digital breast tomosynthesis. Proc. SPIE, 14th International Workshop on Breast Imaging (IWBI 2018) 10718: 107180R, July 2018 doi: 10.1117/12.2318029. Epub 2018 Jul 6. PMID: 38222313
  2. Bakic PR, Barufaldi B, Pokrajac DD, Weinstein SP, Maidment ADA: Optimized simulation of breast anatomy for virtual clinical trials. Proc. SPIE, 14th International Workshop on Breast Imaging (IWBI 2018) 10718: 107181X, July 2018 doi: 10.1117/12.2318525.
  3. Bakic PR, Pokrajac DD, Feldman MD, Maidment ADA: Simulation of sequential pathology images for the virtual clinical trials with rad-path correlation. Proc. SPIE, 14th International Workshop on Breast Imaging (IWBI 2018) 10718: 107180F, July 2018 doi: 10.1117/12.2318492.
  4. Barufaldi B, Bakic PR, Pokrajac DD, Lago MA, Maidment ADA: Developing populations of software breast phantoms for virtual clinical trials. Proc. SPIE, 14th International Workshop on Breast Imaging (IWBI 2018) 10718: 107181U, July 2018 doi: 10.1117/12.2318473.
  5. Barufaldi B, McDonald E, Conant EF, Maidment ADA: Diagnostic radiation dose after the implementation of digital breast tomosynthesis screening. Proc. SPIE, 14th International Workshop on Breast Imaging (IWBI 2018) 10718: 107180I, July 2018 doi: 10.1117/12.2318140.
  6. Lau KC, Hsu JC, Naha PC, Chhour P, Hastings R, Stein JM, McDonald ES, Cormode DP, Maidment ADA: Acquisition parameters for dual-energy contrast-enhanced digital mammography using a micelle-based all-in-one nanoparticle (AION) contrast agent: a phantom study. 14th International Workshop on Breast Imaging (IWBI 2018). Proc. SPIE 10718: 107180N, July 2018 doi: 10.1117/12.2318093.

2019 SPIE

  1. Acciavatti RJ, Barufaldi B, Vent TL, Wileyto EP, Maidment ADA: Personalization of x-ray tube motion in digital breast tomosynthesis using virtual Defrise phantoms. Proc. SPIE, Medical Imaging 2019: Physics of Medical Imaging 10948: 109480B, March 2019 doi: 10.1117/12.2511780. Epub 2019 Mar 1. PMID: 38106641
  2. Bakic PR, Dustler M, Förnvik D, Timberg P, Ng S, Maidment ADA, Zackrisson S, Tingberg A: Artifact reduction in simultaneous tomosynthesis and mechanical imaging of the breast. Proc. SPIE, Medical Imaging 2019: Physics of Medical Imaging 10948: 109483X, March 2019 doi: 10.1117/12.2512743.
  3. Barufaldi B, Bakic PR, Maidment ADA: Multiple-reader, multiple-case ROC analysis for determining the limit of calcification detection in tomosynthesis. Proc. SPIE, Medical Imaging 2019: Physics of Medical Imaging, 10948: 109480N, March 2019 doi: 10.1117/12.2512884.
  4. Costa AC, Barufaldi B, Borges LR, Biehl M, Maidment ADA, Vieira MAC: Analysis of feature relevance using an image quality index applied to digital mammography. Proc. SPIE, Medical Imaging 2019: Physics of Medical Imaging 10948: 109485R, March 2019 doi: 10.1117/12.2512975.
  5. Lau KC, Hsu JC, Cederström B, Cormode DP, Maidment ADA: Evaluation of silver sulfide nanoparticles as a contrast agent for spectral photon-counting digital mammography: a phantom study. Proc. SPIE, Medical Imaging 2019: Physics of Medical Imaging 10948: 109481J, March 2019 doi: 10.1117/12.2511757.
  6. Lee DL, Maidment ADA, Kassaee A, Dong L, Li T, Vent TL, Petroccia H, Irmen P, Malajovich I, Heo K, Kim D, Jang H: Novel direct conversion imaging detector without selenium or semiconductor conversion layer. Proc. SPIE, Medical Imaging 2019: Physics of Medical Imaging 10948: 1094818, March 2019 doi: 10.1117/12.2512127.
  7. Salvadeo DHP, Vimieiro RB, Vieira MAC, Maidment ADA: Bayesian reconstruction for digital breast tomosynthesis using a nonlocal Gaussian Markov random field a priori model. Proc. SPIE, Medical Imaging 2019: Physics of Medical Imaging 10948: 109485C, March 2019 doi: 10.1117/12.2513140.
  8. Vasudev V, Piepers B, Maidment ADA, Kimpe T, Platisa L, Philips W, Bakic PR: Simulation pipeline for virtual clinical trials of dermatology images. Proc. SPIE, Medical Imaging 2019: Physics of Medical Imaging 10948: 109482D, March 2019 doi: 10.1117/12.2512204.
  9. Vent TL, Barufaldi B, Maidment ADA: Simulation and experimental validation of high-resolution test objects for evaluating a next-generation digital breast tomosynthesis prototype. Proc. SPIE, Medical Imaging 2019: Physics of Medical Imaging 10948: 109480M, March 2019 doi: 10.1117/12.2511304.
  10. Vent TL, Lepore B, Maidment ADA: Evaluating the imaging performance of a next-generation digital breast tomosynthesis prototype. Proc SPIE, Medical Imaging 2019: Physics of Medical Imaging 10948: 109480K, March 2019 doi: 10.1117/12.2511990.
  11. Vimieiro RB, Borges LR, Caron RF, Barufaldi B, Bakic PR, Maidment ADA, Vieira MAC: Noise measurements from reconstructed digital breast tomosynthesis. Proc. SPIE, Medical Imaging 2019: Physics of Medical Imaging 10948: 109480C, March 2019 doi: 10.1117/12.2512977.

SPIE 2020

  1. Acciavatti RJ, Cohen EA, Maghsoudi OH, Gastounioti A, Pantalone L, Hsieh M, Conant EF, Scott CG, Winham SJ, Kerlikowske K, Vachon C, Maidment ADA, Kontos D: Robust radiomic feature selection in digital mammography: understanding the effect of imaging acquisition physics using phantom and clinical data analysis. Proc. SPIE, Medical Imaging 2020: Image Perception, Observer Performance, and Technology Assessment 11314: 113140W, March 2020 doi.org/10.1117/12.2549163. Epub 2020 Mar 16. PMID: 37982014
  2. Acciavatti RJ, Vent TL, Barufaldi B, Wileyto EP, Noël PB, Maidment ADA: Proposing rapid source pulsing for improved super-resolution in digital breast tomosynthesis. Proc. SPIE, Medical Imaging 2020: Image Perception, Observer Performance, and Technology Assessment 11312: 113125G, March 2020 doi.org/10.1117/12.2542551. Epub 2020 Mar 16. PMID: 37927528
  3. Bakic PR, Dustler M, Ng S, Maidment ADA, Zackrisson S, Tingberg A: Pre-processing for image quality improvement in simultaneous DBT and mechanical imaging. Proc. SPIE, Medical Imaging 2020: Image Perception, Observer Performance, and Technology Assessment 11312: 1131257, March 2020 doi.org/10.1117/12.2550986.
  4. Barufaldi B, Vent TL, Acciavatti RJ, Bakic PR, Noël PB, Conant EF, Maidment ADA: Determining the optimal angular range of the x-ray source motion in tomosynthesis using virtual clinical trials. Proc. SPIE, Medical Imaging 2020: Image Perception, Observer Performance, and Technology Assessment 11312: 11312OI, March 2020 doi.org/10.1117/12.2549600. PMID: 32435081
  5. Jonnalagadda A, Lago MA, Barufaldi B, Bakic PR, Abbey CK, Maidment ADA, Eckstein MP: Evaluation of convolutional neural networks for search in 1/f 2.8 filtered noise and digital breast tomosynthesis phantoms. Proc. SPIE, Medical Imaging 2020: Image Perception, Observer Performance, and Technology Assessment 11316: 1131617, March 2020 doi.org/10.1117/12.2549362.
  6. Lago MA, Barufaldi B, Bakic PR, Abbey CK, Maidment ADA, Eckstein MP: Foveated model observer to predict human search performance on virtual digital breast tomosynthesis phantoms. Proc. SPIE, Medical Imaging 2020: Image Perception, Observer Performance, and Technology Assessment 11316: 11316OV, March 2020 doi.org/10.1117/12.2550485.
  7. Shapira N, Fokuhl J, Schultheiß M, Beck S, Kopp FK, Pfeiffer D, Dangelmaier J, Pahn G, Sauter AP, Renger B, Fingerle AA, Maidment ADA, Rummeny EJ, Albarqouni S, Navab N, Noël PB: Benefit of dual energy CT for lesion localization and classification with convolutional neural networks. Proc. SPIE, Medical Imaging 2020: Image Perception, Observer Performance, and Technology Assessment 11312: 113121Q, March 2020 doi.org/10.1117/12.2549291.
  8. Vasudev V, Paepe LD, Maidment ADA, Kimpe T, Platisa L, Philips W, Bakic PR: Impact of chromophores on colour appearance in a computational skin model. Proc. SPIE, Medical Imaging 2020: Image Perception, Observer Performance, and Technology Assessment 11312: 1131232, March 2020 doi.org/10.1117/12.2548962.

IWDM 2020

  1. Acciavatti RJ, Cohen EA, Maghsoudi OH, Gastounioti A, Pantalone L, Hsieh M, Barufaldi B, Bakic PR, Chen J, Conant EF, Kontos D, Maidment ADA: Calculation of radiomic features to validate the textural realism of physical anthropomorphic phantoms for digital mammography. Proc. IWBI, 15th International Workshop on Breast Imaging 2020 11513: 1151309, May 2020 doi.org/10.1117/12.2564363. Epub 2020 May 22. PMID: 37818096
  2. Acciavatti RJ, Vent TL, Barufaldi B, Wileyto EP, Noël PB, Maidment ADA: Super-resolution in digital breast tomosynthesis: limitations of the conventional system design and strategies for optimization. Proc. IWBI, 15th International Workshop on Breast Imaging 2020 11513: 11513OV, May 2020 doi.org/10.1117/12.2563839. Epub 2020 May 22. PMID: 37842133
  3. Bakic PR, Dustler M, Lau KC, Maidment ADA, Zackrisson S, Tingberg A: Evaluation of a flat fielding method for simultaneous DBT and MI acquisition. Proc. IWBI, 15th International Workshop on Breast Imaging 2020 11513: 11513OU, May 2020 doi.org/10.1117/12.2564377.
  4. Barufaldi B, Vent TL, Acciavatti RJ, Bakic PR, Noël PB, Maidment ADA: MRMC ROC analysis of calcification detection in tomosynthesis using computed super resolution and virtual clinical trials. Proc. IWBI, 15th International Workshop on Breast Imaging 2020 11513: 1151313, May 2020 doi.org/10.1117/12.2564118.
  5. Torlegård B, Tingberg A, Zackrisson S, Barufaldi B, Maidment ADA, Dustler M, Bakic PR: Identifying and modelling clinical subpopulations from the Malmö breast tomosynthesis screening trial. Proc. IWBI, 15th International Workshop on Breast Imaging 2020 11513: 1151316, May 2020 doi.org/10.1117/12.2564095.
  6. Vent TL, Barufaldi B, Acciavatti RJ, Maidment ADA: Simulation of high-resolution test objects using non-isocentric acquisition geometries in next-generation digital tomosynthesis. Proc. IWBI, 15th International Workshop on Breast Imaging 2020 11513: 1151317, May 2020 doi.org/10.1117/12.2561098.

SPIE 2021

  1. Acciavatti RJ, Vent TL, Choi CJ, Wileyto EP, Noël PB, Maidment ADA: Development of Magnification Tomosynthesis for Superior Resolution in Diagnostic Mammography SPIE, Medical Imaging. Hilde Bosmans; Wei Zhao; Lifeng Yu (eds.). Published in SPIE Proceedings Physics of Medical Imaging 11595: 115951J, February 2021 doi: 10.1117/12.2580280. Epub 2021 Feb 15. PMID: 37701413
  2. Martin DA, Vent TL, Choi CJ, Barufaldi B, Acciavatti RJ, Maidment ADA : Signal-to-Noise Ratio and Contrast-to-Noise Ratio Measurements for Next Generation Tomosynthesis. Proc. SPIE, Medical Imaging 2021: Physics of Medical Imaging. Hilde Bosmans; Wei Zhao; Lifeng Yu (eds.). SPIE Proceedings, 11595: 115951L, February 2021 doi: 10.1117/12.2582279.
  3. Choi CJ, Vent TL, Acciavatti RJ, Maidment ADA: Analysis of Digital Breast Tomosynthesis Acquisition Geometries in Sampling Fourier Space. Proc. SPIE, Medical Imaging Physics of Medical Imaging. Hilde Bosmans; Wei Zhao; Lifeng Yu (eds.). Published in SPIE Proceedings 11595: 115954W, February 2021 doi: 10.1117/12.2582229.
  4. P. Singh, J. Choi, T. L. Vent, and A. D. A. Maidment: Novel reconstruction algorithms that facilitate real-time 4D tomosynthesis. Proc. SPIE 11595, February 2021.
  5. Renaan F. Brandão, L. R. Borges, B. Barufaldi, T. L. Vent, Renayto F. Caron, Bruno B. Oliveira, A. D. A. Maidment, and M. A. C. Vieira: Iterative method to achieve noise variance stabilization in single raw digital breast tomosynthesis Proc. SPIE 11595, February 2021.
  6. Vent TL, Barufaldi B, Acciavatti RJ, Krishnamoorthy S, Surti S, Maidment ADA: Next generation tomosynthesis image acquisition optimization for dedicated PET-DBT attenuation corrections. SPIE, Medical Imaging 2021. Hilde Bosmans; Wei Zhao; Lifeng Yu (eds.) (eds.). SPIE Proceedings Physics of Medical Imaging, 11595(11595): 115954V-1 - 115954V-7, February 2021 doi: 10.1117/12.2581097.
  7. Varun Vasudev, Lode De Paepe, Andrew D. Maidment, Tom Kimpe, Ljiljana Platisa, Wilfried Philips, Predrag Bakic: Effects of smartphone sensor characteristics on dermatoscopic images: a simulation study. Proc. SPIE Medical Imaging. Physics of Medical Imaging, 11595, 2021.

SPIE 2022

  1. Acciavatti RJ, Choi CJ, Vent TL, Barufaldi B, Maidment ADA: Achieving isotropic super-resolution with a non-isocentric acquisition geometry in a next-generation tomosynthesis system. SPIE Proceedings Medical Imaging 2022: Physics of Medical Imaging, 12031, 2022. doi: 10.1117/12.2612451 Epub 2022 Apr 4. PMID: 37692411
  2. Choi, C. J., Vent, T. L., Geagan, MJ, Noel PB, Maidment, A. D. A.: Investigation of optimal angular range and projection density for next generation tomosynthesis. SPIE Proceedings Medical Imaging. Physics of Medical Imaging, 12031, 2022.
  3. Dong V, Maidment TD, Borges LR, Barufaldi B, Ng S, Maidment ADA: Assessment of patch-based mammogram denoising methods using virtual clinical trials and deep learning: trade-off between denoising strength and preservation of structural details. in Medical Imaging 2022: Physics of Medical Imaging, Proceedings of the SPIE, vol. 12031, 120311W. doi:10.1117/12.2612900 (Apr 2022).
  4. Joao P. V. Teixeira, Telmo M. Silva Filho, Thais G. do Rego, Yuri B. Malheiros, Magnus Dustler, Predrag R. Bakic, Trevor L. Vent, Raymond J. Acciavatti, Srilalan Krishnamoorthy, Suleman Surti, Andrew D. A. Maidment, Bruno Barufaldi: Novel Perlin-based phantoms using 3D models of compressed breast shapes and fractal noise. SPIE Proceedings Medical Imaging 2022. Physics of Medical Imaging; (2022) 12031, 2022 doi.org/10.1117/12.2612565.
  5. Meyer S, Shi SZ, Shapira N, Maidment ADA, Noel PB: Quantitative wave-optical simulation study of the dark-field signal in speckle-based X-ray imaging. SPIE Proceedings Medical Imaging 2022. Physics of Medical Imaging; (2022), 12031, 2022.
  6. Rodrigo de Barros Vimieiro, Lucas Rodrigues Borges, Bruno Barufaldi, Andrew Maidment, Ge Wang, Marcelo Andrade da Costa Vieira: Assessment of training strategies for convolutional neural network to restore low-dose digital breast tomosynthesis projections. SPIE Proceedings Medical Imaging Physics of Medical Imaging, 12031, 2022 doi.org/10.1117/12.2609945.
  7. Singh P, Choi CJ, Vent TL, Barufaldi B, Acciavatti RJ, Conant EF, Maidment ADA: Mathematical foundations of a novel reconstruction algorithm that facilitates real-time 4D tomosynthesis. SPIE Proceedings Medical Imaging 2022. Physics of Medical Imaging, 12031, 2022. doi: 10.1117/12.2608299
  8. Vent TL, Acciavatti RJ, Choi CJ, Barufaldi B, Krishnamoorthy S, Borges L, Kuo J, Ringer P, Ng S, Surti S, Maidment ADA. : Pre-clinical evaluation and optimization of image quality for a next generation tomosynthesis prototype. SPIE Proceedings Medical Imaging 2022. Physics of Medical Imaging; (2022), 12031, 2022.

IWDM 2022

  1. Choi CJ, Barufaldi B, Teixeira JPV, Acciavatti RJ, and Maidment ADA. Spatial dependency of lesion detectability in digital breast tomosynthesis. In 16th International Workshop on Breast Imaging (IWBI 2022). Proc. SPIE 12286, 289-296. (2022). doi: 10.1117/12.2626272
  2. Vimieiro R, Borges L, Caron R, Barufaldi B, Maidment ADA, Wang G, Vieira MAC. Suppressing noise correlation in digital breast tomosynthesis using convolutional neural network and virtual clinical trials. Proc SPIE 12286, 122861B, 2022.
  3. Costa A, Vimieiro R, Borges L, Barufaldi B, Maidment ADA, Vieira MAC. Assessment of video frame interpolation network to generate digital breast tomosynthesis projections. Proc SPIE 12286, 122861D, 2022.
  4. da Nobrega YNG, Carvalhal G, Teixeira JPV, Camargo B de, Rego T do, Malheiros Y, Silva Filho TME, Vent TL, Acciavatti RJ, Maidment ADA, Barufaldi B. Multiclass segmentation of suspicious findings in simulated breast tomosynthesis images using a U-Net. Proc SPIE 12286, 122860L, 2022. doi: 10.1117/12.2626225

SPIE 2023

  1. Choi CJ, Acciavatti RJ, and Maidment ADA. Spatial dependency of multiplanar reconstruction in digital breast tomosynthesis. In Medical Imaging 2023: Physics of Medical Imaging. Proc. SPIE 12463, 124632B (7 April 2023) doi: 10.1117/12.2653139 Epub 2023 Apr 7. PMID: 37492275
  2. Soares L, Brandao R, Borges L, Caron R, Barufaldi B, Maidment ADA, Vieira MAC. Assessing the impact of correlated noise in digital mammography: a virtual clinical trial. Proc SPIE 12467, 1246714, 2023.
  3. Vimieiro R, Borges L, Barufaldi B, Maidment ADA, Caron R, Sabino SMP, Wang G, Vieira MAC. Computational method to artificially insert clusters of microcalcifications in digital breast tomosynthesis. Proc SPIE 12463, 124632N, 2023.

SPIE 2024

  1. Barufaldi B, Choi CJ, Teixeira JPV, Dustler M, Englander RB, do Rego TG, Malheiros YB, Silva Filho TM, Hossain B, Lee J, Maidment ADA. Representation of complex mammary parenchyma texture in tomosynthesis using simplex noise simulations. Proceedings of the SPIE 12925-149. 21 February 2024
  2. Hossain B, Barufaldi B, Maidment ADA, Nishikawa RM, Lee J. Developing an image-domain transformation technique for adapting deep learning algorithms: preliminary work using simulated tomosynthesis of breast patches. Proceedings of the SPIE, 12927-58, 22 February 2024 VITM 2024
  3. Acciavatti RJ, Singh P, Choi CJ, Maidment ADA: Simulation Tools to Optimize the Scanning Motion for Next-Generation Tomosynthesis. Proceedings Virtual Imaging Trials in Medicine 2024 Page: 73-77, May 2024 Notes: doi: 10.48550/arXiv.2405.05359
  4. Choi CJ, Barufaldi B, Teixeira JPV, Acciavatti RJ, Maidment ADA: Comparative Evaluation of Ray-Tracing and Monte Carlo Virtual Clinical Trials Pipelines for Lesion Detection in Digital Breast Tomosynthesis. Proceedings Virtual Imaging Trials in Medicine 2024 Page: 116-121, May 2024 Notes: doi: 10.48550/arXiv.2405.05359

IWBI 2024

  1. Singh P, Choi CJ, Barufaldi B, Maidment ADA, Acciavatti RJ: Exploring advanced 2D acquisitions in breast tomosynthesis: T-shaped and Pentagon geometries. Proc. SPIE, 17th International Workshop on Breast Imaging (IWBI 2024) Maryellen L. Giger, Heather M. Whitney, Karen Drukker, Hui Li (eds.). 13174: 1317406, May 2024 Notes: doi: 10.1117/12.3027054.
  2. Dong, V., Barufaldi, B., Mankowski, W., Silva Filho, T. M., McCarthy, A. M., Kontos, D. and Maidment, A. D., “Explainable radiomics to characterize breast density and tissue complexity: preliminary findings,” 17th International Workshop on Breast Imaging (IWBI 2024), H. Li, M. L. Giger, K. Drukker, and H. M. Whitney, Eds., 86, SPIE (2024).