Sensor Mappings - slipx06/sunsynk-power-flow-card GitHub Wiki
Solar
Card Attribute |
Modbus Register |
Unit |
Sunsynk |
Solarman |
E-Linter (template sensor) |
pv1_power_186 |
186 |
1W |
PV1 input power |
PV1 Power |
{{state_attr('sensor.sunsynk_input', 'pv1') |
pv2_power_187 |
187 |
1W |
PV2 input power |
PV2 Power |
{{state_attr('sensor.sunsynk_input', 'pv2') |
pv3_power_188 |
188 |
1W |
PV3 input power |
|
{{state_attr('sensor.sunsynk_input', 'pv3') |
pv4_power_189 |
189 |
1W |
PV4 input power |
|
{{state_attr('sensor.sunsynk_input', 'pv4') |
pv1_v_109 |
109 |
0.1V |
DC voltage 1 |
PV1 Voltage |
{{state_attr('sensor.sunsynk_input', 'pvIV_0_vpv') |
pv2_v_111 |
111 |
0.1V |
DC voltage 2 |
PV2 Voltage |
{{state_attr('sensor.sunsynk_input', 'pvIV_1_vpv') |
pv3_v_113 |
113 |
0.1V |
DC voltage 3 |
|
{{state_attr('sensor.sunsynk_input', 'pvIV_2_vpv') |
pv4_v_115 |
115 |
0.1V |
DC voltage 4 |
|
{{state_attr('sensor.sunsynk_input', 'pvIV_3_vpv') |
pv1_i_110 |
110 |
0.1A |
DC current 1 |
PV1 Current |
{{state_attr('sensor.sunsynk_input', 'pvIV_0_ipv') |
pv2_i_112 |
112 |
0.1A |
DC current 2 |
PV2 Current |
{{state_attr('sensor.sunsynk_input', 'pvIV_1_ipv') |
pv3_i_114 |
114 |
0.1A |
DC current 3 |
|
{{state_attr('sensor.sunsynk_input', 'pvIV_2_ipv') |
pv4_i_116 |
116 |
0.1A |
DC current 4 |
|
{{state_attr('sensor.sunsynk_input', 'pvIV_3_ipv') |
solarday_108 |
108 |
0.1kWh |
Day PV PowerWh |
Daily Production |
{{state_attr('sensor.sunsynk_input', 'etoday') |
Battery
Card Attribute |
Modbus Register |
Unit |
Sunsynk |
Solarman |
E-Linter (template sensor) |
batchargeday_70 |
70 |
0.1kWh |
Day_Batt_Charge _PowerWh |
|
{{state_attr('sensor.sunsynk_battery', 'etodayChg') |
batdischargeday_71 |
71 |
0.1kWh |
Day_Batt_Discharge_PowerWh |
|
{{state_attr('sensor.sunsynk_battery', 'etodayDischg') |
battery_out_190 |
190 |
1W |
Battery output power |
Battery Power |
{{state_attr('sensor.sunsynk_battery', 'power') |
battery_voltage_183 |
183 |
0.01V |
Battery voltage |
Battery Voltage |
{{state_attr('sensor.sunsynk_battery', 'voltage') |
battery_soc_184 |
184 |
1% |
Battery capacity |
Battery SOC |
{{state_attr('sensor.sunsynk_battery', 'soc') |
battery_current_191 |
191 |
0.01A |
Battery output current |
|
{{state_attr('sensor.sunsynk_battery', 'current') |
Grid
Card Attribute |
Modbus Register |
Unit |
Sunsynk |
Solarman |
E-Linter (template sensor) |
inverter_load_grid_169 |
169 |
1W |
L1L2 Total power of grid side L1L2 |
Total Grid Power |
{{state_attr('sensor.sunsynk_grid', 'power') |
grid_buy_day_76 |
76 |
0.1kWh |
Day_GridBuy_Power Wh |
Daily Energy Bought |
{{state_attr('sensor.sunsynk_grid', 'etodayFrom') |
grid_sell_day_77 |
77 |
0.1kWh |
Day_GridSell_Power Wh |
Daily Energy Sold |
{{state_attr('sensor.sunsynk_grid', 'etodayTo') |
grid_external_power_172 |
172 |
1W |
Grid external Total Power |
External CT L1 Power + External CT L2 Power |
{{state_attr('sensor.sunsynk_grid', 'limiterTotalPower') |
Load
Card Attribute |
Modbus Register |
Unit |
Sunsynk |
Solarman |
E-Linter (template sensor) |
essential_power |
178* |
1W |
Load side Total power |
Total Load Power |
{{state_attr('sensor.sunsynk_load', 'totalpower') |
loadday_84 |
84 |
0.1kWh |
SG:Day_Load_Power Wh |
Daily Load Consumption |
{{state_attr('sensor.sunsynk_load', 'dailyUsed') |
aux_power_166 |
166 |
1W |
GenGen Do micro inverse power input |
Micro-inverter Power |
{{state_attr('sensor.sunsynk_output', 'poweraux') |
*Calculated through internal card logic if non-essential is used
Inverter
Card Attribute |
Modbus Register |
Unit |
Sunsynk |
Solarman |
E-Linter (template sensor) |
use_timer_248 |
248 |
0/1 |
Time of Use Selling enabled |
|
{% if state_attr('sensor.sunsynk_settings', 'peakAndVallery') == 1 %} on {% else %} off {% endif %} |
priority_load_243 |
243 |
0/1 |
Energy management model |
|
{% if state_attr('sensor.sunsynk_settings', 'energyMode:') == 1 %} on {% else %} off {% endif %} |
inverter_grid_voltage_154 |
154 |
0.1V |
L1-N Inverter output voltage L1-N |
Grid Voltage L1 |
{{state_attr('sensor.sunsynk_output', 'vip_0_volt') |
inverter_load_freq_192 |
192 |
0.01Hz L |
Load frequency |
Load Frequency |
{{state_attr('sensor.sunsynk_output', 'fac') |
inverter_out_164 |
164 |
0.01A |
L1 Inverter output current L1 |
Current L1 |
{{state_attr('sensor.sunsynk_output', 'vip_0_current') |
inverter_out_175 |
175 |
1W |
Inverter output Total power |
Total Power |
{{state_attr('sensor.sunsynk_output', 'totalpower') |
grid_status_194 |
194 |
0/1 |
Grid side relay status |
Grid-connected Status |
{{state_attr('sensor.sunsynk_grid', 'gridonline') |
inverter_status_59 |
59 |
[0-5] |
Run state |
Running Status |
{{ state_attr("sensor.sunsynk_invertor_list", "infos_0_gatewayVO_status") }} |