List of confirmed working air con units - revk/ESP32-Faikout GitHub Wiki

Please update this if you use the Faikin and find it works with your model.

The code should work with a BRP069B41, BRP069C41, or similar WiFi modules work connecting to S21 or X50 ports.

Mostly models will be S21 unless otherwise specified. Please do add more detail if you can, or ask in a discussion.

Current Amazon listing (UK) and Faikin Australia are the the models that support 5V working on Tx and Rx.

Connector

See Wiring.

Known working models

Model Description Notes
FTKM50UV Wall Mount (India) Outdoor unit: RKM50UV. S21, works with Type-D Faikin cable, all core features working (Power, Mode, Temp, Fan, Swing, Powerful, Econo). Tested with Home Assistant + MQTT + Apple Home (Siri).
FTXM20M2V1B
FTXM25M2V1B
FTXM35M2V1B
FTXM42M2V1B
ATXM20M2V1B
ATXM25M2V1B
ATXM35M2V1B
CTXM15M2V1B
FTXTM30M2V1B
S403 Type D cable
CTXF20TVMA
CTXF25TVMA
CTXF35TVMA
Multi-Lite S403 Type D cable
CTXF50TVMA Multi-Lite S403 Type E cable
FFA25A2VEB9
FFA35A2VEB9
FFA50A2VEB9
FFA60A2VEB9
Control board part number 4024680 X50A and X35A present Type C cable
FJAP22BA
FJAP28BA
FJAP36BA
FJAP45BA
FJAP56BA
FJAP63BA
FJAP71BA
FXAQ20AVLT
FXAQ20AVM
FXAQ20AVM2
FXAQ20AVM4
FXAQ20AVMS
FXAQ25AVLT
FXAQ25AVM
FXAQ25AVM2
FXAQ25AVM4
FXAQ25AVMS
FXAQ32AVLT
FXAQ32AVM
FXAQ32AVM2
FXAQ32AVM4
FXAQ32AVMS
FXAQ40AVLT
FXAQ40AVM
FXAQ40AVM2
FXAQ40AVM4
FXAQ40AVMS
FXAQ50AVLT
FXAQ50AVM
FXAQ50AVM2
FXAQ50AVM4
FXAQ50AVMS
FXAQ63AVLT
FXAQ63AVM
FXAQ63AVM2
FXAQ63AVM4
FXAQ63AVMS
Control board part number 4024680 X50A and X35A present Type F cable (Molex micro-lock socket)
FTXZ25NV1B
FTXZ35NV1B
FTXZ50NV1B
US7 Ururu Sarara 7 S21 present Type A cable
Control of features unique to the to the US7 (humiditiy control etc.) currently not supported. Currently everything that is shared with a regular Daikin split system works, as far as we know.
FTXF20WVMA
FTXF25WVMA
FTXF35WVMA
FTXF46WVMA
FTXF50WVMA
FTKF25WVMA (Cool Only)
Daikin Lite series S403 Type D cable
FTXF50F5V1B UK Model, 2025 S403 Type D cable Although I made my own
FTXF60WVMA
FTXF71WVMA
Daikin Lite series S403 Type E cable
CTXS50HVLD
FTKS18FVMS
FTKS18GV2S
FTKS50FVM
FTKS50FVM4
FTKS50FVMA
FTKS50FVMV
FTKS50GVMA
FTKS50GVMG
FTKS50GVMG4
FTKS50KVM
FTXS50FVMA
FTXS50FVMA8
FTXS50FVMV
FTXS50GVMA
FTXS50GVMV
FTXS50KVM
All use control board model 1731941 S21 present Type A cable
FTKS50KAVMA
FTKS50KVMA
FTXS50KAVMA
FTXS50KAVMN
FTXS50KVMA
All use control board model 4007240 S21 present Type A cable
CTXS60HVLD
FTKS24FVMS
FTKS60FVM
FTKS60FVM4
FTKS60FVMA
FTKS60FVMV
FTKS60GVMA
FTKS60KVM
FTXS60FVMA
FTXS60FVMA8
FTXS60FVMV
FTXS60GVMA
FTXS60GVMV
FTXS60KVM
All use control board model 1731958 Type A S21 present Type A cable
CTXS71HVLD
FTKS28GV2S
FTKS71FVMA
FTKS71FVMV
FTKS71GVMA
FTKS71KVM
FTXS71FVMA
FTXS71FVMA8
FTXS71FVMV
FTXS71GVMA
FTXS71GVMV
FTXS71KVM
All use control board model 1731965 S21 present Type A cable
CTXS25HVLD
FTKS25EVMA
FTKS25GVMA
FTKS25KVM
FTXS25EVMA
FTXS25EVMA8
FTXS25GVMA
FTXS25KVM
All use control board model 16167J S21 present Type A cable
FTKS25DVMA
FTKS25EVMA4
FTKS25EVMV
FTKS25GVM4
FTKS25GVMV
FTKS25JVMG
FTKS25JVMG9
FTXS25DVMA
FTXS25EVMV
FTXS25GVMV
All use control board model 1616679 S21 present Type A cable
FTXS12WVJU9 Wall mount, Canada S21 Type A cable
FDMA71AV1A Ducted, New Zealand X50A port, uses Type C cable
FTXV85LVMA
FTXV95LVMA
XL series S21 Type A cable
FTKF20TVMA
FTKF25TVMA
FTKF35TVMA
FTKF46TVMA
FTKF50TVMA
Lite series S403 Type D cable
FTKF60TVMA
FTKF71TVMA
Lite series S403 Type E cable
FDYQ71LAV1
FDYQ100LAV1
FDYQ125LAV1
FDYQ140LAV1
FDYQ160LAV1
FDYQ180LAV1
FDYQ200LAV1
FDYQ250LAV1
FDYQ71LBV1
FDYQ100LBV1
FDYQ125LBV1
FDYQ140LBV1
FDYQ160LBV1
FDYQ180LBV1
FDYQ200LBV1
FDYQ140LCV1
FDYQ180LCV1
FDYQ200LCV1
FDYQ250LCV1
FDYQ71LV1
FDYQ100LV1
FDYQ125LV1
FDYQ140LV1
FDYQ160LV1
FDYQ180LV1
FDYQ200LV1
FDYQ250LV1
FDYQN71LAV1
FDYQN100LAV1
FDYQN125LAV1
FDYQN140LAV1
FDYQN160LAV1
FDYQN200LAV1
FDYQN250LAV1
FDYQN71LBV1
FDYQN100LBV1
FDYQN140LBV1
FDYQN180LBV1
FDYQN200LBV1
FDYQN250LBV1
FDYQN180LCV1
FDYQN200LCV1
FDYQN71LV1
FDYQN100LV1
FDYQN125LV1
FDYQN140LV1
FDYQN160LV1
FDYQN180LV1
FDYQN200LV1
FDYQN250LV1
FDYQT71LAV1
FDYQT100LAV1
FDYQT125LAV1
FDYQT160LAV1
FDYQT180LAV1
FDYQT200LAV1
FDYQT250LAV1
FDYQT140LBV1
FDYQT180LBV1
FDYQT200LBV1
FXMQ160PV1A
FXMQ180PV1A
FXMQ200PV1A
FXMQ250PV1A
FDYQ/FDMQ series ducted systems
for:
FDYQ180LV1
FDYQ200LV1
FDYQ250LV1
FDYQN180LV1
FDYQN200LV1
FDYQN250LV1, visual the control board to confirm white (not blue) X50A port present. Blue ports are inactive.
X50A and X35A present Type C cable
FTX(N)xxNMVJU Aurora (Canada) S403 Type E cable
FTXxxAXVJU 19 Series (Canada) S21 Type A cable
FCAxxxCVMA Ceiling cassette type X50A Type F cable (Molex micro-lock socket)
FCAxxCAVMA Ceiling cassette type X50A Type F cable (Molex micro-lock socket)
ATXM25A5V1B Daikin 'Siesta' Wall-mount (2025) S21 Type B cable (smaller PAP S21 socket)
ATXN25NV1B9 Daikin 'Siesta' Wall-mount CN_WIRED connector
ATXN35NV1B9 Daikin 'Siesta' Wall-mount CN_WIRED connector
FTXJ25PVMAW
FTXJ35PVMAW
FTXJ50PVMAW
FTXJ25PVMAS
FTXJ35PVMAS
FTXJ50PVMAS
Zena S21 Type A cable
FTXJ25TVMAK
FTXJ25TVMAW
FTXJ35TVMAK
FTXJ35TVMAW
FTXJ50TVMAK
FTXJ50TVMAW
FTXJ60TVMAK
FTXJ60TVMAW
Zena S21 Type B cable
FDYA100AV1 FDYA100AV19 FDYA125AV1 FDYA125AV19 FDYA140AV1 FDYA140AV19 FDYA160AV1 FDYA160AV19 FDYA71AV1 FDYA71AV19 FDYA85AV1 FDYA85AV19 Inverter ducted (FDYAxxAV1 models)
Premium inverter ducted (FDYAxxAV19 models)
Uses X50A port, Type C cable

Mainboard (EC117029-24[A]) contained in FDYA160AV19 made in Australia from at least April 2025 uses X50A port, Type F cable
FDYAN160AV1 FDYAN100AV1 FDYAN125AV1 FDYAN140AV1 FDYAN160AV1 FDYAN71AV1 FDYAN85AV1 inverter ducted (Australian) Uses X50A port, Type F cable
FTKSxxKVMA L-series S21 Type A cable
FTKM20QVMA
FTKM25QVMA
FTKM35QVMA
FTKM46QVMA
Cora cooling only S403 Type D cable
FTKM50QVMA
FTKM60QVMA
FTKM71QVMA
Cora cooling only S403 Type E cable
FTXV20WVMA
FTXV20W1VMA
FTXV20W2VMA
FTXV25WVMA
FTXV25W1VMA
FTXV25W2VMA
FTXV35WVMA
FTXV35W1VMA
FTXV35W2VMA
FTXV46WVMA
FTXV46W1VMA
FTXV46W2VMA
Cora S403 Type D cable
FTXV50WVMA
FTXV50W1VMA
FTXV50W2VMA
FTXV60WVMA
FTXV60W1VMA
FTXV60W2VMA
FTXV71WVMA
FTXV71W1VMA
FTXV71W2VMA
Cora S403 Type E cable
FTXV80WVMA
FTXV90WVMA
FTXV90WVMA
XL series S21 Type B cable
FTXV20UVMA
FTXV25UVMA
FTXV35UVMA
FTXV46UVMA
Cora S403 Type D cable
FTXV50UVMA
FTXV60UVMA
FTXV71UVMA
Cora S403 Type E cable
FTXM20QVMA
FTXM25QVMA
FTXM35QVMA
FTXM46QVMA
Cora S403 Type D cable
FTXM50QVMA
FTXM60QVMA
FTXM71QVMA
Cora S403 Type E cable
FTXMxxUVMA Alira S21 Type A cable, may also use Type D
FTXM20UVMA
FTXM20UVMZ
FTXV20W1VMA
FTXV20WVMA
FTXV35W2VMA
Control board part number 4025223 S403 - Type D
FTXM25UVMA
FTXM25UVMZ
FTXV20W2VMA
FTXV25W1VMA
FTXV25WVMA
Control board part number 4025224 S403 - Type D
FTXM35UVMA
FTXM35UVMZ
FTXV25W2VMA
FTXV35W1VMA
FTXV35WVMA
Control board part number 4025225 S403 - Type D
FTXM35M2V1B Wall mounted S21 present Type A cable, fits inside the case.
FTXM46UVMA
FTXM46UVMZ
FTXV46W1VMA
FTXV46W2VMA
FTXV46WVMA
Control board part number 4025226 S403 - Type D
FTXM50UVMA
FTXM50UVMZ
FTXV50WVMA
Control board part number 4025227 S403 - Type E
FTXM60UVMA
FTXM60UVMZ
FTXV60WVMA
Control board part number 4025228 S403 - Type E
FTXM71UVMA
FTXM71UVMZ
FTXV71WVMA
Control board part number 4025229 S403 - Type E
FTXMxxWVMA Alira X split system S21 Type B cable (smaller PAP S21 socket)
FTXMxxW2VMA Alira X split system S21 Type B cable (smaller PAP S21 socket) guide here
FTXM20YVMA
FTXM25YVMA
FTXM35YVMA
Alira X split system S403 Type D cable. Advice: check control board for pre-installed BRP067A42 (Daikin OEM MOBILE CONTROLLER) which will instead require Type B cable
FTXB12BXVJU Entra wall mount S21, lead not pre-installed, fits inside the case
FTXJ25MV1BS Wall mount S21 Type A cable Control board model 5016741
FTXM20A2V1B Wall mount Fits inside the case. S21 Type B cable
FTXM25A2V1B Wall mount Fits inside the case. S21 Type B cable
FDXM25F3V1B9 Ducted X50A Type C cable
ATKSxxE2V1B
ATXSxxE2V1B
FTKSxxD3VML
FTKSxxD3VMW
FTXSxxD3VML
FTXSxxD3VMW
FTKSxxDVMW9
FTXSxxDVMW9
Wall-Mount S21 Type A cable
FTXS12LVJU Wall-Mount S21 Type A cable
FTXS09LVJU Wall-Mount S21 Type A cable
FTXS24LVJU Wall-Mount S21 Type A cable
FTXS25BVMA Wall-Mount S21 Type A cable, powerful not working
FTXSxxDAVMW Wall-Mount S21 Type A cable, powerful not working #329
FTXSxxD2VMW
FTXSxxD2VMW
Wall-Mount S21 Type A cable, powerful not working #329
FTXS35DAVMW Wall-Mount S21 Type A cable, powerful not working #329
FTXSxxKVMA Wall-Mount Standard S21 Type A cable, fits inside the case
FTXS35K2V1B Wall-Mount S21 Type A cable, fits inside the case
FTXS60BVMB Wall-Mount S21, Type A cable fits inside the case with 20cm patch cable. Uses JST EH 2.5mm Pitch 5P connector (Aliexpress > Same direction - 20cm - 5P). Use a multimeter to figure out where pins 4 (14.4V) and 5 (GND) are and make sure all wires are 1:1, as even when choosing "Same direction" some wires can still come in reverse order. The best way to ensure you're connecting the plug correctly is to ensure pin 4 (14.4V) is connected to pin 4 on the Faikin board which has a "12V" mark on back. You will need to use an X-acto to carefully lift the lever on the connector to passthrough the cables via the shielded electronics box in order to install the Faikin board outside it - you can also use this opportunity to swap the red and black wires to match pins 4 and 5, respectively. This way the red wire will carry 14.4V and the black wire will be GND, instead of being the green and yellow ones.
FLKS60BVMB Wall-Mount S21 Type A cable, same as FTXS60BVMB, had to cross the 1:1 cable.
FTXS71JVMA Wall-Mount S21 Type A cable, fits inside the case
FTXS35G2V1B Wall-Mount S21 Type A cable, powerful not working #329
FTX24UVJU Wall-Mount S21, fits inside the case
FTXS15WVJU9 Wall-Mount S21, fits inside the case
FTXS09WVJU9 Wall-Mount S21, fits inside the case
CTXS07LVJU Wall-Mount
CTXS07WVJU9 Wall-Mount S21, fits inside the case
CTXS09HVJU Wall mount S21 connector present, lead not pre-installed
ADEA100A2VEB 
ADEA125A2VEB 
ADEA35A2VEB
ADEA50A2VEB
ADEA60A2VEB
ADEA71A2VEB
Sky Air X50A and X35A Type C cable
FTXM20R2V1B Perfera wall-mounted Working with S21 socket - see #49
FTXF20D5V1B Sensira wall-mounted Working with ESP8266 port S403 Type D cable
FTXF35D5V1B Sensira wall-mounted S403 Type D cable
FTXF42D5V1B Sensira wall-mounted S403 Type D cable
FVXG25K2V1B
FVXG35K2V1B
FVXG50K2V1B
Nexura Series Floor Standing Unit No radiant heating control (as with official controller) S21 Type A cable
FVXS25KV1A
FVXS35KV1A
FVXS50KV1A
FVXS35LV1A
FVXS45LV1A
FVXS50LVMA
FVXS60LVMA
FVXS71LVMA
Floor standing L-series S21 Type A cable
FDXS25EAVMB
FDXS12LVJU
Concealed ceiling unit S21, Older unit (2006)
FDXS50CVMA Slim Concealed Ceiling Unit S21
FDXS50CVMB Slim Concealed Ceiling Unit S21, Older unit (2008)
FTXJ20A2V1BW Daikin Emura 3 Photos - bought an EKRS21 cable, had to join s21 male-to-male - More photos to open the device
FTXJ35A2V1BB
FTXJ25A2V1BB
Daikin Emura 3 See this Topic Take care with PIN assignment
FTXSxxG2V1B Daikin Perfera S21 socket with no 5V power (only 14.5). TTL 3.3V compatible. Does not allow: Powerful and Eco modes control and reporting, Power consumption, FAN quiet mode, presence sensor. Fan, Mode, Power, H and V swing, Ext-Int-Coil temp, compressor idle state working
FTXPxxMxxxxx Daikin Comfora S21 (no lead installed), does not work with 3.3V signals. Works with 5V signal or open drain signal. See #62
FTXS50JVMA 2010 wall-mount S21 Type A cable
FTX25K2V1B Needs newest model, with 5V Tx working
CTXMxxRxV1B Perfera 2022 new (smaller) S21 port (PAP-05V-S), original Daikin adapter cable to old S21 P/N: EKRS21, all 5 cables need to be connected, usable place for original wifi module 45mm X 36mm (cut PCB to size) below metal shield (pictures)
FTXMxxRxV1B Perfera 2022 new (smaller) S21 port (PAP-05V-S), original Daikin adapter cable to old S21 P/N: EKRS21, all 5 cables need to be connected, usable place for original wifi module 45mm X 36mm (cut PCB to size) below metal shield (pictures)
FTXS35CVMB8 Old 2006 wall mount model connection via S21 port, all seems to be working except for "Powerful" mode. Home Leave, Silent and Sensor are not available options
FTXS35GVMA 2010 Wall-Mount S21 port. Fits perfectly inside the case.
FNA35A2VEB9 FAN-A9 Concealed floor standing unit S21 port, ducted outside of unit. Note that on the version commercialized in France (Europe ?), there is no S21 port outside the unit. Wiring has to be done with X50A (Type F) and X35A connectors. Everything works perfectly.
FBA71BVLT Ceiling(TW) X50A with X35
CDXS35EAVMA
CDXS18LVJU
Ceiling casette S21 Type A cable
CDXS50DVMT Ceiling(TW) Original S21 adapter (JST EKR-5)
FTXS25DVMT Wall-Mount(TW) Original S21 adapter (JST EKR-5)
FTXV**SVLT Wall-Mount(TW) Original S21 adapter (JST EKR-5)
FTXM**RVLT Wall-Mount(TW) Original S21 adapter (JST EKR-5)
FDXV**RVLT Wall-Mount(TW) Original S21 adapter (JST EKR-5)
FTXM**VVLT Wall-Mount(TW) Mini S21 port (JST PAP-05V-S)
FTHF40VVLT Wall-Mount(TW) S403 Connector (JST PAP-10V-S)
FTHF20RVLT Wall-Mount(TW) S403 Connector (JST PAP-10V-S)
FTKS35DVMT Wall-Mount Old Model(2005)
FBQ50C7VEB Concealed Ceiling Unit Uses X50 port
FBQ100C7VEB Concealed Ceiling Unit Uses X50A port & X35A (type F cable on faikin.au)
FTXS71LVMA S21 Connector present, I used 4 F-F jumper leads between main board and faikin.
FTXA42A2V1 Stylish 2022 S21 Connector present, used 1x 5016537, 1x EKRS21. fits perfectly in place of the original WiFi module
FTXTA30C2V1BW Stylish 2025 New S21 PA Connector with pitch 2.0mm. Needs JST-EH5 to PA (JST-PAP-05V-S) cable, aka Type B cable (smaller PAP S21 socket)
FTXA25C2V1BW
FTXA50C2V1BW
Stylish 2025 S21 Connector present
CTXM15R Perfera 2021 S21 Connector present, used 1x 5016537, 1x EKRS21. fits perfectly in place of the original WiFi module
FTXM20R Perfera 2021 S21 Connector present, used 1x 5016537, 1x EKRS21. fits perfectly in place of the original WiFi module
FTXR42EV Wall-Mount S21 Connector. Everything working correctly except specific humidity modes and outside air renewal of Ururu Sarara models.
FTXR12WVJUW9
FTXR09WVJUS9
FTXR12WVJUS9
Wall-Mount Emura Series S21 connector, Type A cable. Cable was factory provided. Module easily fits in mounting location for OEM module.
FTXS20LVMA
FTXS25LVMA
FTXS35LVMA
FTXS46LVMA
FTXS50LVMA
FTXS60LVMA
FTXS71LVMA
FTXS85LVMA
FTXS95LVMA
L-series reverse cycle S21 Type A cable
FTKS20LVMA
FTKS25LVMA
FTKS35LVMA
FTKS46LVMA
FTKS50LVMA
FTKS60LVMA
FTKS71LVMA
L-series cooling only S21 Type A cable
FTXA42C2V1BW Wall Mount S21 Connector present, used 5x F-F dupont jumper cables and one EKRS21 as the EKRS21 is male and faikin board is male. Took original wifi board out and put faikin in its little hole. Fits very nicely. Had to guess which way round the pinout was. Didn't blow it up the wrong way round, so all good! Probably works with all FTXA**C2V1BW range. All features work.
FTXNG09AXVJU S21 Connector present, joined two s21 (EH) male-to-male cables
FVXMxxA2V1B Perfera Floor Standing Unit New S21 PA Connector with pitch 2.0mm. Needs JST-EH5 to PA (JST-PAP-05V-S) cable. Fits in place of the original WiFi module, but also works in parallel of it.
FVXMxxA3V1B Perfera Floor Standing Unit New S21 PA Connector, needs JST EH to PA (PAP-05V-S) cable (same as new Perfera Wall-Mount). Fits in place of the original WiFi module. Most things working. Not working: Heat+, Floor Warming mode. The Led/Eye brightness can be changed setting noled to false.
FVXMxxB2V1B Perfera Wall-Mount New S21 PA Connector, needs JST EH to PA (PAP-05V-S) cable. I used a JST EH 2 JST EH cable and took the housing off one end and hooked the pins up straight (isolate with tape to prevent shorts!) Pin 4 on the airco had 14v to ground, but seemed to be lacking current and Faikin wouldnt boot. Hooked up pin 1 (5V) on the airco to pin 4 on the Faikin and then it worked. Fits in place of the original WiFi module.
FTKS35CVMB8 Wall-Mount Old Model(2004) S21 Connector 5 pin, reversed connector orientation.
FTXS40JVLT Wall-Mount S21
FTXM20PVMA
FTXM25PVMA
FTXM35PVMA
FTXM46PVMA
FTXM50PVMA
FTXM60PVMA
FTXM71PVMA
FTXM85PVMA
FTXM95PVMA
Cora S21, Type A cable
CTXM15A2V1B
FTXM20A2V1B
FTXM25A2V1B
FTXM35A2V1B
FTXM42A2V1B
FTXM50A2V1B
FTXM60A2V1B
FTXM71A2V1B
Perfera 2024 S21 port, use Type B cable. Faikin fits in original wifi module location (PCB must be cut to size). Can also be mounted below mainboard box if you want to preserve the original wifi module, below the box on the bottom right there is a black plastic tab/wedge pointing to the rear of the unit on which the Faikin can be mounted with double sided tape. All options are available including demand-control (multi-split with 4MXM80A2V1B9).
FTXM46RVMZ Wall-Mount S403 Connector present, requires 5V signals, used 5x F-F dupont jumper cables then connected to header
CTXA15AW Stylish Wall-Mount New S21 PA Connector, needs JST EH to PA (PAP-05V-S) cable
FTXAxxC2V1Bx Stylish Wall-Mount S21 (new style JST PAP-05V-S connector so requires a cable with that or the EKRS21 to convert it back to JST EH-5; pinout is the same either way). Built-in wifi has its own connector, not S21, so I left that alone. I used EHR-5, BEH-001T-P0.6, PAP-05V-S, SPHD-001T-P0.5 and 22 AUD multicore to make a cable (crimp tool required). Ideal cable length is 35-37cm. There's space underneath the end wiring panel to tape the Faikin to. Can alternatively use cable that comes with original wifi BRP069C4x
FTXMxxA2V1B Perfera 2024 S21 Connector present
FTXMxxA5V1B Perfera 2024 S21 with 2.0mm JST-PA Connector present, space on the right side near the thermistor. Type B cable
ATX35JV1B Daikin 'Siesta' Wall-mount No native S21, used a KRP980B1 wired remote interface board.
FTXS35K3V1B Wall-mount Native S21, used an ESP C3 supermini with a transformer from 14Vcc to 5Vcc and a logic TTL converter for Rx and Tx.
FTKU35BV1MF Daikin Deluxe (Wall-Mount) S21 Connector present, used 30cm 5pin JST EHR 2.5mm to Dupont cable. Powerful, Eco+ mode not support
ATXD25A Siesta Wall-Mount Used S403 Connector with a pin-to-pin custom cable
ATXF25E Siesta Wall-Mount Used S403 Connector with a pin-to-pin custom cable
FTXMxxR2V1B Perfera Wall-Mount S21 Connector on upper PCB at the upper side - isolated from mains - PAP connector - 5V supply voltage available and working fine with a ESP32 WROOM
FTXM35R Perfera Wall-Mount Used the new S21 JST-PA Connector with 2.0mm pitch, see pictures for details.
ATXC25CV1B Wall-mount Native S21, used an ESP C6 with a bump converter from 14Vcc to 5Vcc and a logic TTL converter for Rx and Tx. Not all queries working - getting NAK from S21 for RH/RI/Ra/RL queries
FTXF35C5V1B Wall-mount 2021/06 Native S21, the supplied connector did not work. But a set of female to female dupont cables did the job.
FTXG26EV1BW Wall-Mount Native S21, the supplied connector did work but a female to female cables required.
FTXG35LV1BW Wall-Mount Native S21, cable included and fits inside dedicated compartment
FTXF35E5V1B Sensira Wall-Mounted S403 connector Outback digital type D cable
CTXM20RVMA
CTXM25RVMA
CTXM35RVMA
CTXM46RVMA
Australian indoor wall mounted 2.5/3.5kW Cora unit for R32 multi split system Type D cable
CTXM50RVMA
CTXM60RVMA
CTXM71RVMA S403
Cora S403 Type E cable
CTXM85RVMA
CTXM95RVMA
Cora S21 Type A cable
CTXM20RVMA
CTXM60RVMA
CTXM50RVMA
Australian indoor wall mounted 6kW Cora unit for R32 multi split system S403 connector with slightly misfitting JST PAP-10V-S connector. Very likely will work also on CT(X/K)M(60/71)RVMA. CTXM50RVMA basic controls only work not econo, powerful, quiet etc.. CTXM50RVMA uses Type E cable
FTXS42JV1B Wall-Mounted S21 connector - Tested with ESP8266 fork
FTXC35BV1B Wall-Mount Model 2019, S21, used original Daikin-Cables from BRP069B41 (4 leads)
ATXF35D5V1B Wall-Mount Model 2022, S21, used original Daikin-Cables from BRP069B41 (4 leads)
FX60GV1B Wall-Mounted S21 connector - Tested with ESP8266 fork
FTXB12AXVJU Wall-Mount (US) CN_WIRED connector
FTXB18AXVJU Wall-Mount (US) CN_WIRED connector
FTX12AXVJU Wall-Mount S21 (Type A - Fits Jumper Cables)
FTX12NMVJU Wall-mount, US, digital interface S21 Type A cable
ATXS25G Wall-Mounted S21 connector
FTC35NV14 Wall-Mounted S403 socket present, used THIS cable (Type E), all modes working.
FTM35JV14
FTM50JV14
Wall-Mounted S21 socket present, used THIS cable (Type A), Powerful mode not working, all other modes ok.
FTV15AXV14
FTV20AXV14
Wall-Mounted CN_WIRED socket present, used THIS cable (Type G), all modes working.
3WM05J-AILFA-R56
3WM07J-AILFA-R56
Wall-Mounted, Control board model 4017046 CN_WIRED socket present, used THIS cable (Type G), all modes working.
FBQ71C7VEB Ducted Has X50 port, but port is disabled - Tried with ESP8266 port - DOES NOT WORK
FTXV35UVMA Wall-Mount Native S21. Econo, Powerful, Stream/filter, Sensor mode, Comfort mode, Quiet outdoor all toggle off.
FTXS20D3VMW Wall-Mount 2008 model Native S21 (cable not provided), Powerful mode does not work, all other modes ok.
FTXG35EV1BW Wall-Mount 2007 model Native S21 (cable not provided), Powerful mode does not work, all other modes ok.
FDXM60F9/FDXM50F3 Slim Ducted Uses X50 port, requires a cable. Used the one from the previous offical Wifi Unit.
GTHT50UV16VZ Wall-Mounted (Kenya) S403 connector
FVXMxxFV1B9 Perfera Wall-Mount (old) S21 Connector - note that it's a slightly bigger connector
FTXS25K3V1B Wall Mounted Used S403 Connector with a pin-to-pin custom cable
FTXS60GV1B Wall Mounted S21, powerful not working #329
FTXS20G2V1B Wall Mounted S21, powerful not working #329
FDXM25F9/FDXM35F9 Ducted Needs cable, uses X50A port + X35A for powering the Faikin
FTKG60TV Wall-Mount (India) S403 connector. Used a JST-XH (10-pin) to Dupont cable. Cable alterations - (1) Removed Pin 2,3,7,8,9,10 (2) Cut off protruding clips
FTYN60GV1A Wall-Mount S21 Type A cable 2.5mm JST-EH
FTYN25DV1A FTYN25GV1A Wall mount, Australia Control board model 1710564 Type A S21 present Type A cable
FTYN35DV1A FTYN35GV1A Wall mount, Australia Control board model 1710610 Type A S21 present Type A cable
FTY25CVMA
FTY25CVMA8
use control board model 1527351 S21 present Type A cable
FTY35CVMA
FTY35CVMA8
use control board model 1527368 S21 present Type A cable
FWT04GATNMV1 Daikin Fan Coil CN_WIRED connector
FWT03CATNMV1
FWT04CATNMV1
Fan Coil (wall mounted) CN_WIRED connector, see this comment for pinout (the connector on the board is a JST 2.0 PH 5-pin male connector)
FWT02GT Daikin Fan Coil CN_WIR connector interface (slightly different to CN_WIRED)
ADEQ100C2VEB Ducted X50A + X35A
FFA60A2VEB9 Cassette X50A + X35A no swing controls
FTXD50JVEA
FTKD50/60/71J Series
FTXD50/60/71J Series
All use control board model 2P058884 (EX468) S21 present [Type A cable]
FTXG25JV1BW
FTXG35JV1BW
Wall Mount S21 [Type A cable]

(https://www.faikin.au/products/faikin-and-cable-1), fits inside the case.
Only confirmed on FTXD50JVEA, but based on [service manual] (https://www.nodevice.com/service-manuals/conditioners/daikin/ftkd50jve/874292) the other listed series use the same board so should also work.

⚠️ **GitHub.com Fallback** ⚠️