List of confirmed working air con units - revk/ESP32-Faikout GitHub Wiki
Please update this if you use the Faikin and find it works with your model.
The code should work with a BRP069B41, BRP069C41, or similar WiFi modules work connecting to S21 or X50 ports.
Mostly models will be S21 unless otherwise specified. Please do add more detail if you can, or ask in a discussion.
Current Amazon listing (UK) and Faikin Australia are the the models that support 5V working on Tx and Rx.
See Wiring.
| Model | Description | Notes |
|---|---|---|
| FTKM50UV | Wall Mount (India) | Outdoor unit: RKM50UV. S21, works with Type-D Faikin cable, all core features working (Power, Mode, Temp, Fan, Swing, Powerful, Econo). Tested with Home Assistant + MQTT + Apple Home (Siri). |
| FTXM20M2V1B FTXM25M2V1B FTXM35M2V1B FTXM42M2V1B ATXM20M2V1B ATXM25M2V1B ATXM35M2V1B CTXM15M2V1B FTXTM30M2V1B |
S403 Type D cable | |
| CTXF20TVMA CTXF25TVMA CTXF35TVMA |
Multi-Lite | S403 Type D cable |
| CTXF50TVMA | Multi-Lite | S403 Type E cable |
| FFA25A2VEB9 FFA35A2VEB9 FFA50A2VEB9 FFA60A2VEB9 |
Control board part number 4024680 | X50A and X35A present Type C cable |
| FJAP22BA FJAP28BA FJAP36BA FJAP45BA FJAP56BA FJAP63BA FJAP71BA FXAQ20AVLT FXAQ20AVM FXAQ20AVM2 FXAQ20AVM4 FXAQ20AVMS FXAQ25AVLT FXAQ25AVM FXAQ25AVM2 FXAQ25AVM4 FXAQ25AVMS FXAQ32AVLT FXAQ32AVM FXAQ32AVM2 FXAQ32AVM4 FXAQ32AVMS FXAQ40AVLT FXAQ40AVM FXAQ40AVM2 FXAQ40AVM4 FXAQ40AVMS FXAQ50AVLT FXAQ50AVM FXAQ50AVM2 FXAQ50AVM4 FXAQ50AVMS FXAQ63AVLT FXAQ63AVM FXAQ63AVM2 FXAQ63AVM4 FXAQ63AVMS |
Control board part number 4024680 | X50A and X35A present Type F cable (Molex micro-lock socket) |
| FTXZ25NV1B FTXZ35NV1B FTXZ50NV1B |
US7 Ururu Sarara 7 | S21 present Type A cable Control of features unique to the to the US7 (humiditiy control etc.) currently not supported. Currently everything that is shared with a regular Daikin split system works, as far as we know. |
| FTXF20WVMA FTXF25WVMA FTXF35WVMA FTXF46WVMA FTXF50WVMA FTKF25WVMA (Cool Only) |
Daikin Lite series | S403 Type D cable |
| FTXF50F5V1B | UK Model, 2025 | S403 Type D cable Although I made my own |
| FTXF60WVMA FTXF71WVMA |
Daikin Lite series | S403 Type E cable |
| CTXS50HVLD FTKS18FVMS FTKS18GV2S FTKS50FVM FTKS50FVM4 FTKS50FVMA FTKS50FVMV FTKS50GVMA FTKS50GVMG FTKS50GVMG4 FTKS50KVM FTXS50FVMA FTXS50FVMA8 FTXS50FVMV FTXS50GVMA FTXS50GVMV FTXS50KVM |
All use control board model 1731941 | S21 present Type A cable |
| FTKS50KAVMA FTKS50KVMA FTXS50KAVMA FTXS50KAVMN FTXS50KVMA |
All use control board model 4007240 | S21 present Type A cable |
| CTXS60HVLD FTKS24FVMS FTKS60FVM FTKS60FVM4 FTKS60FVMA FTKS60FVMV FTKS60GVMA FTKS60KVM FTXS60FVMA FTXS60FVMA8 FTXS60FVMV FTXS60GVMA FTXS60GVMV FTXS60KVM |
All use control board model 1731958 | Type A S21 present Type A cable |
| CTXS71HVLD FTKS28GV2S FTKS71FVMA FTKS71FVMV FTKS71GVMA FTKS71KVM FTXS71FVMA FTXS71FVMA8 FTXS71FVMV FTXS71GVMA FTXS71GVMV FTXS71KVM |
All use control board model 1731965 | S21 present Type A cable |
| CTXS25HVLD FTKS25EVMA FTKS25GVMA FTKS25KVM FTXS25EVMA FTXS25EVMA8 FTXS25GVMA FTXS25KVM |
All use control board model 16167J | S21 present Type A cable |
| FTKS25DVMA FTKS25EVMA4 FTKS25EVMV FTKS25GVM4 FTKS25GVMV FTKS25JVMG FTKS25JVMG9 FTXS25DVMA FTXS25EVMV FTXS25GVMV |
All use control board model 1616679 | S21 present Type A cable |
| FTXS12WVJU9 | Wall mount, Canada | S21 Type A cable |
| FDMA71AV1A | Ducted, New Zealand | X50A port, uses Type C cable |
| FTXV85LVMA FTXV95LVMA |
XL series | S21 Type A cable |
| FTKF20TVMA FTKF25TVMA FTKF35TVMA FTKF46TVMA FTKF50TVMA |
Lite series | S403 Type D cable |
| FTKF60TVMA FTKF71TVMA |
Lite series | S403 Type E cable |
| FDYQ71LAV1 FDYQ100LAV1 FDYQ125LAV1 FDYQ140LAV1 FDYQ160LAV1 FDYQ180LAV1 FDYQ200LAV1 FDYQ250LAV1 FDYQ71LBV1 FDYQ100LBV1 FDYQ125LBV1 FDYQ140LBV1 FDYQ160LBV1 FDYQ180LBV1 FDYQ200LBV1 FDYQ140LCV1 FDYQ180LCV1 FDYQ200LCV1 FDYQ250LCV1 FDYQ71LV1 FDYQ100LV1 FDYQ125LV1 FDYQ140LV1 FDYQ160LV1 FDYQ180LV1 FDYQ200LV1 FDYQ250LV1 FDYQN71LAV1 FDYQN100LAV1 FDYQN125LAV1 FDYQN140LAV1 FDYQN160LAV1 FDYQN200LAV1 FDYQN250LAV1 FDYQN71LBV1 FDYQN100LBV1 FDYQN140LBV1 FDYQN180LBV1 FDYQN200LBV1 FDYQN250LBV1 FDYQN180LCV1 FDYQN200LCV1 FDYQN71LV1 FDYQN100LV1 FDYQN125LV1 FDYQN140LV1 FDYQN160LV1 FDYQN180LV1 FDYQN200LV1 FDYQN250LV1 FDYQT71LAV1 FDYQT100LAV1 FDYQT125LAV1 FDYQT160LAV1 FDYQT180LAV1 FDYQT200LAV1 FDYQT250LAV1 FDYQT140LBV1 FDYQT180LBV1 FDYQT200LBV1 FXMQ160PV1A FXMQ180PV1A FXMQ200PV1A FXMQ250PV1A |
FDYQ/FDMQ series ducted systems for: FDYQ180LV1 FDYQ200LV1 FDYQ250LV1 FDYQN180LV1 FDYQN200LV1 FDYQN250LV1, visual the control board to confirm white (not blue) X50A port present. Blue ports are inactive. |
X50A and X35A present Type C cable |
| FTX(N)xxNMVJU | Aurora (Canada) | S403 Type E cable |
| FTXxxAXVJU | 19 Series (Canada) | S21 Type A cable |
| FCAxxxCVMA | Ceiling cassette type | X50A Type F cable (Molex micro-lock socket) |
| FCAxxCAVMA | Ceiling cassette type | X50A Type F cable (Molex micro-lock socket) |
| ATXM25A5V1B | Daikin 'Siesta' Wall-mount (2025) | S21 Type B cable (smaller PAP S21 socket) |
| ATXN25NV1B9 | Daikin 'Siesta' Wall-mount | CN_WIRED connector |
| ATXN35NV1B9 | Daikin 'Siesta' Wall-mount | CN_WIRED connector |
| FTXJ25PVMAW FTXJ35PVMAW FTXJ50PVMAW FTXJ25PVMAS FTXJ35PVMAS FTXJ50PVMAS |
Zena | S21 Type A cable |
| FTXJ25TVMAK FTXJ25TVMAW FTXJ35TVMAK FTXJ35TVMAW FTXJ50TVMAK FTXJ50TVMAW FTXJ60TVMAK FTXJ60TVMAW |
Zena | S21 Type B cable |
| FDYA100AV1 FDYA100AV19 FDYA125AV1 FDYA125AV19 FDYA140AV1 FDYA140AV19 FDYA160AV1 FDYA160AV19 FDYA71AV1 FDYA71AV19 FDYA85AV1 FDYA85AV19 | Inverter ducted (FDYAxxAV1 models) Premium inverter ducted (FDYAxxAV19 models) |
Uses X50A port, Type C cable Mainboard (EC117029-24[A]) contained in FDYA160AV19 made in Australia from at least April 2025 uses X50A port, Type F cable |
| FDYAN160AV1 FDYAN100AV1 FDYAN125AV1 FDYAN140AV1 FDYAN160AV1 FDYAN71AV1 FDYAN85AV1 | inverter ducted (Australian) | Uses X50A port, Type F cable |
| FTKSxxKVMA | L-series | S21 Type A cable |
| FTKM20QVMA FTKM25QVMA FTKM35QVMA FTKM46QVMA |
Cora cooling only | S403 Type D cable |
| FTKM50QVMA FTKM60QVMA FTKM71QVMA |
Cora cooling only | S403 Type E cable |
| FTXV20WVMA FTXV20W1VMA FTXV20W2VMA FTXV25WVMA FTXV25W1VMA FTXV25W2VMA FTXV35WVMA FTXV35W1VMA FTXV35W2VMA FTXV46WVMA FTXV46W1VMA FTXV46W2VMA |
Cora | S403 Type D cable |
| FTXV50WVMA FTXV50W1VMA FTXV50W2VMA FTXV60WVMA FTXV60W1VMA FTXV60W2VMA FTXV71WVMA FTXV71W1VMA FTXV71W2VMA |
Cora | S403 Type E cable |
| FTXV80WVMA FTXV90WVMA FTXV90WVMA |
XL series | S21 Type B cable |
| FTXV20UVMA FTXV25UVMA FTXV35UVMA FTXV46UVMA |
Cora | S403 Type D cable |
| FTXV50UVMA FTXV60UVMA FTXV71UVMA |
Cora | S403 Type E cable |
| FTXM20QVMA FTXM25QVMA FTXM35QVMA FTXM46QVMA |
Cora | S403 Type D cable |
| FTXM50QVMA FTXM60QVMA FTXM71QVMA |
Cora | S403 Type E cable |
| FTXMxxUVMA | Alira | S21 Type A cable, may also use Type D |
| FTXM20UVMA FTXM20UVMZ FTXV20W1VMA FTXV20WVMA FTXV35W2VMA |
Control board part number 4025223 | S403 - Type D |
| FTXM25UVMA FTXM25UVMZ FTXV20W2VMA FTXV25W1VMA FTXV25WVMA |
Control board part number 4025224 | S403 - Type D |
| FTXM35UVMA FTXM35UVMZ FTXV25W2VMA FTXV35W1VMA FTXV35WVMA |
Control board part number 4025225 | S403 - Type D |
| FTXM35M2V1B | Wall mounted | S21 present Type A cable, fits inside the case. |
| FTXM46UVMA FTXM46UVMZ FTXV46W1VMA FTXV46W2VMA FTXV46WVMA |
Control board part number 4025226 | S403 - Type D |
| FTXM50UVMA FTXM50UVMZ FTXV50WVMA |
Control board part number 4025227 | S403 - Type E |
| FTXM60UVMA FTXM60UVMZ FTXV60WVMA |
Control board part number 4025228 | S403 - Type E |
| FTXM71UVMA FTXM71UVMZ FTXV71WVMA |
Control board part number 4025229 | S403 - Type E |
| FTXMxxWVMA | Alira X split system | S21 Type B cable (smaller PAP S21 socket) |
| FTXMxxW2VMA | Alira X split system | S21 Type B cable (smaller PAP S21 socket) guide here |
| FTXM20YVMA FTXM25YVMA FTXM35YVMA |
Alira X split system | S403 Type D cable. Advice: check control board for pre-installed BRP067A42 (Daikin OEM MOBILE CONTROLLER) which will instead require Type B cable |
| FTXB12BXVJU | Entra wall mount | S21, lead not pre-installed, fits inside the case |
| FTXJ25MV1BS | Wall mount | S21 Type A cable Control board model 5016741 |
| FTXM20A2V1B | Wall mount | Fits inside the case. S21 Type B cable |
| FTXM25A2V1B | Wall mount | Fits inside the case. S21 Type B cable |
| FDXM25F3V1B9 | Ducted | X50A Type C cable |
| ATKSxxE2V1B ATXSxxE2V1B FTKSxxD3VML FTKSxxD3VMW FTXSxxD3VML FTXSxxD3VMW FTKSxxDVMW9 FTXSxxDVMW9 |
Wall-Mount | S21 Type A cable |
| FTXS12LVJU | Wall-Mount | S21 Type A cable |
| FTXS09LVJU | Wall-Mount | S21 Type A cable |
| FTXS24LVJU | Wall-Mount | S21 Type A cable |
| FTXS25BVMA | Wall-Mount | S21 Type A cable, powerful not working |
| FTXSxxDAVMW | Wall-Mount | S21 Type A cable, powerful not working #329 |
| FTXSxxD2VMW FTXSxxD2VMW |
Wall-Mount | S21 Type A cable, powerful not working #329 |
| FTXS35DAVMW | Wall-Mount | S21 Type A cable, powerful not working #329 |
| FTXSxxKVMA | Wall-Mount | Standard S21 Type A cable, fits inside the case |
| FTXS35K2V1B | Wall-Mount | S21 Type A cable, fits inside the case |
| FTXS60BVMB | Wall-Mount | S21, Type A cable fits inside the case with 20cm patch cable. Uses JST EH 2.5mm Pitch 5P connector (Aliexpress > Same direction - 20cm - 5P). Use a multimeter to figure out where pins 4 (14.4V) and 5 (GND) are and make sure all wires are 1:1, as even when choosing "Same direction" some wires can still come in reverse order. The best way to ensure you're connecting the plug correctly is to ensure pin 4 (14.4V) is connected to pin 4 on the Faikin board which has a "12V" mark on back. You will need to use an X-acto to carefully lift the lever on the connector to passthrough the cables via the shielded electronics box in order to install the Faikin board outside it - you can also use this opportunity to swap the red and black wires to match pins 4 and 5, respectively. This way the red wire will carry 14.4V and the black wire will be GND, instead of being the green and yellow ones. |
| FLKS60BVMB | Wall-Mount | S21 Type A cable, same as FTXS60BVMB, had to cross the 1:1 cable. |
| FTXS71JVMA | Wall-Mount | S21 Type A cable, fits inside the case |
| FTXS35G2V1B | Wall-Mount | S21 Type A cable, powerful not working #329 |
| FTX24UVJU | Wall-Mount | S21, fits inside the case |
| FTXS15WVJU9 | Wall-Mount | S21, fits inside the case |
| FTXS09WVJU9 | Wall-Mount | S21, fits inside the case |
| CTXS07LVJU | Wall-Mount | |
| CTXS07WVJU9 | Wall-Mount | S21, fits inside the case |
| CTXS09HVJU | Wall mount | S21 connector present, lead not pre-installed |
| ADEA100A2VEB ADEA125A2VEB ADEA35A2VEB ADEA50A2VEB ADEA60A2VEB ADEA71A2VEB |
Sky Air | X50A and X35A Type C cable |
| FTXM20R2V1B | Perfera wall-mounted | Working with S21 socket - see #49 |
| FTXF20D5V1B | Sensira wall-mounted | Working with ESP8266 port S403 Type D cable |
| FTXF35D5V1B | Sensira wall-mounted | S403 Type D cable |
| FTXF42D5V1B | Sensira wall-mounted | S403 Type D cable |
| FVXG25K2V1B FVXG35K2V1B FVXG50K2V1B |
Nexura Series Floor Standing Unit | No radiant heating control (as with official controller) S21 Type A cable |
| FVXS25KV1A FVXS35KV1A FVXS50KV1A FVXS35LV1A FVXS45LV1A FVXS50LVMA FVXS60LVMA FVXS71LVMA |
Floor standing L-series | S21 Type A cable |
| FDXS25EAVMB FDXS12LVJU |
Concealed ceiling unit | S21, Older unit (2006) |
| FDXS50CVMA | Slim Concealed Ceiling Unit | S21 |
| FDXS50CVMB | Slim Concealed Ceiling Unit | S21, Older unit (2008) |
| FTXJ20A2V1BW | Daikin Emura 3 | Photos - bought an EKRS21 cable, had to join s21 male-to-male - More photos to open the device |
| FTXJ35A2V1BB FTXJ25A2V1BB |
Daikin Emura 3 | See this Topic Take care with PIN assignment |
| FTXSxxG2V1B | Daikin Perfera | S21 socket with no 5V power (only 14.5). TTL 3.3V compatible. Does not allow: Powerful and Eco modes control and reporting, Power consumption, FAN quiet mode, presence sensor. Fan, Mode, Power, H and V swing, Ext-Int-Coil temp, compressor idle state working |
| FTXPxxMxxxxx | Daikin Comfora | S21 (no lead installed), does not work with 3.3V signals. Works with 5V signal or open drain signal. See #62 |
| FTXS50JVMA | 2010 wall-mount | S21 Type A cable |
| FTX25K2V1B | Needs newest model, with 5V Tx working | |
| CTXMxxRxV1B | Perfera 2022 | new (smaller) S21 port (PAP-05V-S), original Daikin adapter cable to old S21 P/N: EKRS21, all 5 cables need to be connected, usable place for original wifi module 45mm X 36mm (cut PCB to size) below metal shield (pictures) |
| FTXMxxRxV1B | Perfera 2022 | new (smaller) S21 port (PAP-05V-S), original Daikin adapter cable to old S21 P/N: EKRS21, all 5 cables need to be connected, usable place for original wifi module 45mm X 36mm (cut PCB to size) below metal shield (pictures) |
| FTXS35CVMB8 | Old 2006 wall mount model | connection via S21 port, all seems to be working except for "Powerful" mode. Home Leave, Silent and Sensor are not available options |
| FTXS35GVMA | 2010 Wall-Mount | S21 port. Fits perfectly inside the case. |
| FNA35A2VEB9 | FAN-A9 Concealed floor standing unit | S21 port, ducted outside of unit. Note that on the version commercialized in France (Europe ?), there is no S21 port outside the unit. Wiring has to be done with X50A (Type F) and X35A connectors. Everything works perfectly. |
| FBA71BVLT | Ceiling(TW) | X50A with X35 |
| CDXS35EAVMA CDXS18LVJU |
Ceiling casette | S21 Type A cable |
| CDXS50DVMT | Ceiling(TW) | Original S21 adapter (JST EKR-5) |
| FTXS25DVMT | Wall-Mount(TW) | Original S21 adapter (JST EKR-5) |
| FTXV**SVLT | Wall-Mount(TW) | Original S21 adapter (JST EKR-5) |
| FTXM**RVLT | Wall-Mount(TW) | Original S21 adapter (JST EKR-5) |
| FDXV**RVLT | Wall-Mount(TW) | Original S21 adapter (JST EKR-5) |
| FTXM**VVLT | Wall-Mount(TW) | Mini S21 port (JST PAP-05V-S) |
| FTHF40VVLT | Wall-Mount(TW) | S403 Connector (JST PAP-10V-S) |
| FTHF20RVLT | Wall-Mount(TW) | S403 Connector (JST PAP-10V-S) |
| FTKS35DVMT | Wall-Mount | Old Model(2005) |
| FBQ50C7VEB | Concealed Ceiling Unit | Uses X50 port |
| FBQ100C7VEB | Concealed Ceiling Unit | Uses X50A port & X35A (type F cable on faikin.au) |
| FTXS71LVMA | S21 Connector present, I used 4 F-F jumper leads between main board and faikin. | |
| FTXA42A2V1 | Stylish 2022 | S21 Connector present, used 1x 5016537, 1x EKRS21. fits perfectly in place of the original WiFi module |
| FTXTA30C2V1BW | Stylish 2025 | New S21 PA Connector with pitch 2.0mm. Needs JST-EH5 to PA (JST-PAP-05V-S) cable, aka Type B cable (smaller PAP S21 socket) |
| FTXA25C2V1BW FTXA50C2V1BW |
Stylish 2025 | S21 Connector present |
| CTXM15R | Perfera 2021 | S21 Connector present, used 1x 5016537, 1x EKRS21. fits perfectly in place of the original WiFi module |
| FTXM20R | Perfera 2021 | S21 Connector present, used 1x 5016537, 1x EKRS21. fits perfectly in place of the original WiFi module |
| FTXR42EV | Wall-Mount | S21 Connector. Everything working correctly except specific humidity modes and outside air renewal of Ururu Sarara models. |
| FTXR12WVJUW9 FTXR09WVJUS9 FTXR12WVJUS9 |
Wall-Mount Emura Series | S21 connector, Type A cable. Cable was factory provided. Module easily fits in mounting location for OEM module. |
| FTXS20LVMA FTXS25LVMA FTXS35LVMA FTXS46LVMA FTXS50LVMA FTXS60LVMA FTXS71LVMA FTXS85LVMA FTXS95LVMA |
L-series reverse cycle | S21 Type A cable |
| FTKS20LVMA FTKS25LVMA FTKS35LVMA FTKS46LVMA FTKS50LVMA FTKS60LVMA FTKS71LVMA |
L-series cooling only | S21 Type A cable |
| FTXA42C2V1BW | Wall Mount | S21 Connector present, used 5x F-F dupont jumper cables and one EKRS21 as the EKRS21 is male and faikin board is male. Took original wifi board out and put faikin in its little hole. Fits very nicely. Had to guess which way round the pinout was. Didn't blow it up the wrong way round, so all good! Probably works with all FTXA**C2V1BW range. All features work. |
| FTXNG09AXVJU | S21 Connector present, joined two s21 (EH) male-to-male cables | |
| FVXMxxA2V1B | Perfera Floor Standing Unit | New S21 PA Connector with pitch 2.0mm. Needs JST-EH5 to PA (JST-PAP-05V-S) cable. Fits in place of the original WiFi module, but also works in parallel of it. |
| FVXMxxA3V1B | Perfera Floor Standing Unit | New S21 PA Connector, needs JST EH to PA (PAP-05V-S) cable (same as new Perfera Wall-Mount). Fits in place of the original WiFi module. Most things working. Not working: Heat+, Floor Warming mode. The Led/Eye brightness can be changed setting noled to false. |
| FVXMxxB2V1B | Perfera Wall-Mount | New S21 PA Connector, needs JST EH to PA (PAP-05V-S) cable. I used a JST EH 2 JST EH cable and took the housing off one end and hooked the pins up straight (isolate with tape to prevent shorts!) Pin 4 on the airco had 14v to ground, but seemed to be lacking current and Faikin wouldnt boot. Hooked up pin 1 (5V) on the airco to pin 4 on the Faikin and then it worked. Fits in place of the original WiFi module. |
| FTKS35CVMB8 | Wall-Mount | Old Model(2004) S21 Connector 5 pin, reversed connector orientation. |
| FTXS40JVLT | Wall-Mount | S21 |
| FTXM20PVMA FTXM25PVMA FTXM35PVMA FTXM46PVMA FTXM50PVMA FTXM60PVMA FTXM71PVMA FTXM85PVMA FTXM95PVMA |
Cora | S21, Type A cable |
| CTXM15A2V1B FTXM20A2V1B FTXM25A2V1B FTXM35A2V1B FTXM42A2V1B FTXM50A2V1B FTXM60A2V1B FTXM71A2V1B |
Perfera 2024 | S21 port, use Type B cable. Faikin fits in original wifi module location (PCB must be cut to size). Can also be mounted below mainboard box if you want to preserve the original wifi module, below the box on the bottom right there is a black plastic tab/wedge pointing to the rear of the unit on which the Faikin can be mounted with double sided tape. All options are available including demand-control (multi-split with 4MXM80A2V1B9). |
| FTXM46RVMZ | Wall-Mount | S403 Connector present, requires 5V signals, used 5x F-F dupont jumper cables then connected to header |
| CTXA15AW | Stylish Wall-Mount | New S21 PA Connector, needs JST EH to PA (PAP-05V-S) cable |
| FTXAxxC2V1Bx | Stylish Wall-Mount | S21 (new style JST PAP-05V-S connector so requires a cable with that or the EKRS21 to convert it back to JST EH-5; pinout is the same either way). Built-in wifi has its own connector, not S21, so I left that alone. I used EHR-5, BEH-001T-P0.6, PAP-05V-S, SPHD-001T-P0.5 and 22 AUD multicore to make a cable (crimp tool required). Ideal cable length is 35-37cm. There's space underneath the end wiring panel to tape the Faikin to. Can alternatively use cable that comes with original wifi BRP069C4x |
| FTXMxxA2V1B | Perfera 2024 | S21 Connector present |
| FTXMxxA5V1B | Perfera 2024 | S21 with 2.0mm JST-PA Connector present, space on the right side near the thermistor. Type B cable |
| ATX35JV1B | Daikin 'Siesta' Wall-mount | No native S21, used a KRP980B1 wired remote interface board. |
| FTXS35K3V1B | Wall-mount | Native S21, used an ESP C3 supermini with a transformer from 14Vcc to 5Vcc and a logic TTL converter for Rx and Tx. |
| FTKU35BV1MF | Daikin Deluxe (Wall-Mount) | S21 Connector present, used 30cm 5pin JST EHR 2.5mm to Dupont cable. Powerful, Eco+ mode not support |
| ATXD25A | Siesta Wall-Mount | Used S403 Connector with a pin-to-pin custom cable |
| ATXF25E | Siesta Wall-Mount | Used S403 Connector with a pin-to-pin custom cable |
| FTXMxxR2V1B | Perfera Wall-Mount | S21 Connector on upper PCB at the upper side - isolated from mains - PAP connector - 5V supply voltage available and working fine with a ESP32 WROOM |
| FTXM35R | Perfera Wall-Mount | Used the new S21 JST-PA Connector with 2.0mm pitch, see pictures for details. |
| ATXC25CV1B | Wall-mount | Native S21, used an ESP C6 with a bump converter from 14Vcc to 5Vcc and a logic TTL converter for Rx and Tx. Not all queries working - getting NAK from S21 for RH/RI/Ra/RL queries |
| FTXF35C5V1B | Wall-mount 2021/06 | Native S21, the supplied connector did not work. But a set of female to female dupont cables did the job. |
| FTXG26EV1BW | Wall-Mount | Native S21, the supplied connector did work but a female to female cables required. |
| FTXG35LV1BW | Wall-Mount | Native S21, cable included and fits inside dedicated compartment |
| FTXF35E5V1B | Sensira Wall-Mounted | S403 connector Outback digital type D cable |
| CTXM20RVMA CTXM25RVMA CTXM35RVMA CTXM46RVMA |
Australian indoor wall mounted 2.5/3.5kW Cora unit for R32 multi split system | Type D cable |
| CTXM50RVMA CTXM60RVMA CTXM71RVMA S403 |
Cora | S403 Type E cable |
| CTXM85RVMA CTXM95RVMA |
Cora | S21 Type A cable |
| CTXM20RVMA CTXM60RVMA CTXM50RVMA |
Australian indoor wall mounted 6kW Cora unit for R32 multi split system | S403 connector with slightly misfitting JST PAP-10V-S connector. Very likely will work also on CT(X/K)M(60/71)RVMA. CTXM50RVMA basic controls only work not econo, powerful, quiet etc.. CTXM50RVMA uses Type E cable |
| FTXS42JV1B | Wall-Mounted | S21 connector - Tested with ESP8266 fork |
| FTXC35BV1B | Wall-Mount | Model 2019, S21, used original Daikin-Cables from BRP069B41 (4 leads) |
| ATXF35D5V1B | Wall-Mount | Model 2022, S21, used original Daikin-Cables from BRP069B41 (4 leads) |
| FX60GV1B | Wall-Mounted | S21 connector - Tested with ESP8266 fork |
| FTXB12AXVJU | Wall-Mount (US) | CN_WIRED connector |
| FTXB18AXVJU | Wall-Mount (US) | CN_WIRED connector |
| FTX12AXVJU | Wall-Mount | S21 (Type A - Fits Jumper Cables) |
| FTX12NMVJU | Wall-mount, US, digital interface | S21 Type A cable |
| ATXS25G | Wall-Mounted | S21 connector |
| FTC35NV14 | Wall-Mounted | S403 socket present, used THIS cable (Type E), all modes working. |
| FTM35JV14 FTM50JV14 |
Wall-Mounted | S21 socket present, used THIS cable (Type A), Powerful mode not working, all other modes ok. |
| FTV15AXV14 FTV20AXV14 |
Wall-Mounted | CN_WIRED socket present, used THIS cable (Type G), all modes working. |
| 3WM05J-AILFA-R56 3WM07J-AILFA-R56 |
Wall-Mounted, Control board model 4017046 | CN_WIRED socket present, used THIS cable (Type G), all modes working. |
| FBQ71C7VEB | Ducted | Has X50 port, but port is disabled - Tried with ESP8266 port - DOES NOT WORK |
| FTXV35UVMA | Wall-Mount | Native S21. Econo, Powerful, Stream/filter, Sensor mode, Comfort mode, Quiet outdoor all toggle off. |
| FTXS20D3VMW | Wall-Mount 2008 model | Native S21 (cable not provided), Powerful mode does not work, all other modes ok. |
| FTXG35EV1BW | Wall-Mount 2007 model | Native S21 (cable not provided), Powerful mode does not work, all other modes ok. |
| FDXM60F9/FDXM50F3 | Slim Ducted | Uses X50 port, requires a cable. Used the one from the previous offical Wifi Unit. |
| GTHT50UV16VZ | Wall-Mounted (Kenya) | S403 connector |
| FVXMxxFV1B9 | Perfera Wall-Mount | (old) S21 Connector - note that it's a slightly bigger connector |
| FTXS25K3V1B | Wall Mounted | Used S403 Connector with a pin-to-pin custom cable |
| FTXS60GV1B | Wall Mounted | S21, powerful not working #329 |
| FTXS20G2V1B | Wall Mounted | S21, powerful not working #329 |
| FDXM25F9/FDXM35F9 | Ducted | Needs cable, uses X50A port + X35A for powering the Faikin |
| FTKG60TV | Wall-Mount (India) | S403 connector. Used a JST-XH (10-pin) to Dupont cable. Cable alterations - (1) Removed Pin 2,3,7,8,9,10 (2) Cut off protruding clips |
| FTYN60GV1A | Wall-Mount | S21 Type A cable 2.5mm JST-EH |
| FTYN25DV1A FTYN25GV1A | Wall mount, Australia Control board model 1710564 | Type A S21 present Type A cable |
| FTYN35DV1A FTYN35GV1A | Wall mount, Australia Control board model 1710610 | Type A S21 present Type A cable |
| FTY25CVMA FTY25CVMA8 |
use control board model 1527351 | S21 present Type A cable |
| FTY35CVMA FTY35CVMA8 |
use control board model 1527368 | S21 present Type A cable |
| FWT04GATNMV1 | Daikin Fan Coil | CN_WIRED connector |
| FWT03CATNMV1 FWT04CATNMV1 |
Fan Coil (wall mounted) | CN_WIRED connector, see this comment for pinout (the connector on the board is a JST 2.0 PH 5-pin male connector) |
| FWT02GT | Daikin Fan Coil | CN_WIR connector interface (slightly different to CN_WIRED) |
| ADEQ100C2VEB | Ducted | X50A + X35A |
| FFA60A2VEB9 | Cassette | X50A + X35A no swing controls |
| FTXD50JVEA FTKD50/60/71J Series FTXD50/60/71J Series |
All use control board model 2P058884 (EX468) | S21 present [Type A cable] |
| FTXG25JV1BW FTXG35JV1BW |
Wall Mount | S21 [Type A cable] |
(https://www.faikin.au/products/faikin-and-cable-1), fits inside the case.
Only confirmed on FTXD50JVEA, but based on [service manual]
(https://www.nodevice.com/service-manuals/conditioners/daikin/ftkd50jve/874292) the other listed series use the same board so should also work.