EEEF - owfs/owfs-doc GitHub Wiki
NAME
UVI, Moisture, Barometer, HUB
- HobbyBoards EE/EF Microprocessor-based slaves: Ultra Violet (UV)
Index sensor, Soil and Leaf moisture measurements, Barometer, 4-channel
hub with switchable branches
SYNOPSIS
General EE device
EE [.]XXXXXXXXXXXX[XX][/[ temperature | version | type_number | temperature_offset | address | crc8 | id | locator | r_address | r_id | r_locator | type ]]
UVI sensor
EE [.]XXXXXXXXXXXX[XX][/[ UVI/UVI | UVI/UVI_offset | UVI/in_case | UVI/valid | temperature | version | type_number | temperature_offset ]]
General EF device
EF [.]XXXXXXXXXXXX[XX][/[ version | type_number | address | crc8 | id | locator | r_address | r_id | r_locator | type ]]
Moisture Meter
moisture/sensor.[0-3|ALL]
moisture/is_moisture.[0-3|ALL|BYTE] |
moisture/is_leaf.[0-3|ALL|BYTE]
moisture/calibrate/min | moisture/calibrate/max |
moisture/calibrate/raw.[0-4|ALL]
Hub
hub/branch.[0-3|ALL|BYTE] | hub/short.[0-3|ALL|BYTE]
FAMILY CODE
EE
Device with temperature
EE
UVI
EF
Device without temperature
EF
Moisture Meter
EF
Hub
TEMPERATURE PROPERTIES
temperature
read-only, floating point
Temperature read every 30 seconds. Resolution .5C (uses an on-board
DS18B20). Temperature is only present in the EE-series devices.
temperature_offset
read-write, floating point
Offset stored on device to apply to temperature readings.
UVI PROPERTIES
UVI/UVI
read-only floating point
UV Index (ultraviolet index) in the range 0.0 to 16.0 resolution .1
Only the UVI version of the EE device has a UVI sensor. Readings made every .5 seconds.
UVI/UVI_offset
read-write, floating point
Signed offset to apply to the UVI measurement. Stored on-device
non-volatile.
UVI/in_case
read-write, yes-no
Flag to apply compensation for the protective case. Stored on-device
non-volatile.
UVI/valid
read-only, yes-no Flag the the EE device type matches the known UVI type.
Moisture Meter
moisture/sensor.0 .. moisture/sensor.3 moisture/sensor.ALL
read-only integer
Up to 4 sensors reading moisture can be attached. OWFS addresses the
sensors as 0 through 3 while the datasheet uses 1-4. Two types of
external sensors are supported (and the data range):
Watermark Soil Moisture Sensor
0-199
Leaf Wetness Sensor
0-99
moisture/is_moisture.0 .. moisture/is_moisture.3 moisture/is_moisture.ALL
moisture/is_leaf.0 .. moisture/is_leaf.3 moisture/is_leaf.ALL
read-write yes_no
Set or get the type of sensor attached to each channel. Note that OWFS
addresses the sensors as 0 through 3 while the datasheet uses 1-4. Two
types of external sensors are supported:
Watermark Soil Moisture
Sensor
Leaf Wetness
Sensor
Note that is_leaf and is_moisture are complementary and clearing one sets the other.
moisture/calibrate/min
moisture/calibrate/max
read-write unsigned integer
Set or get the upper and lower range for the raw data for leaf wetness
scaling. See the datasheet for details.
moisture/calibrate/raw.0 .. moisture/calibrate/raw.3 moisture/calibrate/raw.ALL
read-only unsigned integer
Read the raw leaf wetness values for setting scaling. See the datasheet
for details. Note that OWFS addresses the sensors as 0 through 3 while
the datasheet uses 1-4.
Hub
4-channel hub. Individual branches can be switched on and off.
hub/branch.0 .. hub/branch.3 hub/branch.ALL hub/branch.BYTE
read-write, yes-no
The HobbyBoards hub has four 1-wire bus lines. Each branch is
electricaly isolated from reflections and shorts, and can be optionally
excluded from the 1-wire network.
You can turn each branch on or off by writing 0 (off) or 1 (on) to the corresponding property. Note that OWFS indexes the branches 0 to 3 while the datasheet uses 1 to 4.
The easiest way to turn all the branches on is to write 15 (0x0F) to hub/branch.BYTE
hub/short.0 .. hub/short.3 hub/short.ALL hub/short.BYTE
read-only, yes-no
Is the corresponding branch in "short" condition? (Electrically shorted
out).
IDENTIFICATION PROPERTIES
version
read-only, ascii
Firmware version for the EE/EF device. Reported in nn.nn format where nn
is major/minor decimal value.
Note: This format was changed as of version owfs-2.9p6 at the request of the HobbyBoards. Formerly reported in HH.HH format where HH is a hex digit (0-9A-F).
type_number
read-only, integer
Index of the type of sensor built into this device. Current known
assignments:
1
UVI (Ultraviolet index)
2
Moisture meter
3
Moisture meter with datalogger
4
Sniffer
5
Hub
STANDARD PROPERTIES
address
r_address
read-only, ascii
The entire 64-bit unique ID. Given as upper case hexadecimal digits
(0-9A-F).
address starts with the family code
r address is the address in reverse order, which is often used in
other applications and labeling.
crc8
read-only, ascii
The 8-bit error correction portion. Uses cyclic redundancy check.
Computed from the preceding 56 bits of the unique ID number. Given as
upper case hexadecimal digits (0-9A-F).
family
read-only, ascii
The 8-bit family code. Unique to each type of device. Given as upper
case hexadecimal digits (0-9A-F).
id
r_id
read-only, ascii
The 48-bit middle portion of the unique ID number. Does not include the
family code or CRC. Given as upper case hexadecimal digits (0-9A-F).
r id is the id in reverse order, which is often used in other
applications and labeling.
locator
r_locator
read-only, ascii
Uses an extension of the 1-wire design from iButtonLink company that
associated 1-wire physical connections with a unique 1-wire code. If the
connection is behind a Link Locator the locator will show a unique
8-byte number (16 character hexadecimal) starting with family code
FE.
If no Link Locator is between the device and the master, the
locator field will be all FF.
r locator is the locator in reverse order.
present (DEPRECATED)
read-only, yes-no
Is the device currently present on the 1-wire bus?
type
read-only, ascii
Part name assigned by Dallas Semi. E.g. DS2401 Alternative packaging
(iButton vs chip) will not be distiguished.
ALARMS
None
DESCRIPTION
1-Wire
1-wire is a wiring protocol and series of devices designed and manufactured by Dallas Semiconductor, Inc. The bus is a low-power low-speed low-connector scheme where the data line can also provide power.
Each device is uniquely and unalterably numbered during manufacture. There are a wide variety of devices, including memory, sensors (humidity, temperature, voltage, contact, current), switches, timers and data loggers. More complex devices (like thermocouple sensors) can be built with these basic devices. There are also 1-wire devices that have encryption included.
The 1-wire scheme uses a single bus master and multiple slaves on the same wire. The bus master initiates all communication. The slaves can be individually discovered and addressed using their unique ID.
Bus masters come in a variety of configurations including serial, parallel, i2c, network or USB adapters.
OWFS design
OWFS is a suite of programs that designed to make the 1-wire bus and its devices easily accessible. The underlying principle is to create a virtual filesystem, with the unique ID being the directory, and the individual properties of the device are represented as simple files that can be read and written.
Details of the individual slave or master design are hidden behind a consistent interface. The goal is to provide an easy set of tools for a software designer to create monitoring or control applications. There are some performance enhancements in the implementation, including data caching, parallel access to bus masters, and aggregation of device communication. Still the fundamental goal has been ease of use, flexibility and correctness rather than speed.
EE / EF
The EEEF (3) are a reference platform of microprocessor based 1-wire slaves. In general they require external power, and have an on-board index for the specific capabilities. They are designed by Eric Vickery at HobbyBoards.com
The EE class device uses family code EE and has an included temperature sensor. The EF devices have no temperature sensor,
UVI
The UVI sensor is an implementation of the EE class device with Ultra Violet Index sensing. All it's specific properties are in the UVI/ directory.
ADDRESSING
All 1-wire devices are factory assigned a unique 64-bit address. This address is of the form:
Family Code
8 bits
Address
48 bits
CRC
8 bits
Addressing under OWFS is in hexadecimal, of form:
01.123456789ABC
where 01 is an example 8-bit family code, and 12345678ABC is an example 48 bit address.
The dot is optional, and the CRC code can included. If included, it must be correct.
DATASHEET
UVI
http://www.hobby-boards.com/catalog/links/uvi2-r1/UVI%20Meter%20User%20Manual.pdf
Moisture and Leaf Sensor
http://www.hobby-boards.com/download/manuals/Moisture%20Meter.pdf
4 Channel Hub
http://www.hobby-boards.com/download/manuals/4%20Channel%20Hub.pdf
SEE ALSO
Programs
owfs (1) owhttpd (1) owftpd (1) owserver (1) owdir (1) owread (1) owwrite (1) owpresent (1) owtap (1)
Configuration and testing
owfs (5) owfs.aliasfile (5) owtap (1) owmon (1)
Language bindings
owtcl (3) owperl (3) owcapi (3)
Clocks
DS1427 (3) DS1904 (3) DS1994 (3) DS2404 (3) DS2404S (3) DS2415 (3) DS2417 (3)
ID
DS2401 (3) DS2411 (3) DS1990A (3)
Memory
DS1982 (3) DS1985 (3) DS1986 (3) DS1991 (3) DS1992 (3) DS1993 (3) DS1995 (3) DS1996 (3) DS2430A (3) DS2431 (3) DS2433 (3) DS2502 (3) DS2506 (3) DS28E04 (3) DS28EC20 (3)
Switches
DS2405 (3) DS2406 (3) DS2408 (3) DS2409 (3) DS2413 (3) DS28EA00 (3) InfernoEmbedded (3)
Temperature
DS1822 (3) DS1825 (3) DS1820 (3) DS18B20 (3) DS18S20 (3) DS1920 (3) DS1921 (3) DS1821 (3) DS28EA00 (3) DS28E04 (3) EDS0064 (3) EDS0065 (3) EDS0066 (3) EDS0067 (3) EDS0068 (3) EDS0071 (3) EDS0072 (3) MAX31826 (3)
Humidity
DS1922 (3) DS2438 (3) EDS0065 (3) EDS0068 (3)
Voltage
DS2450 (3)
Resistance
DS2890 (3)
Multifunction (current, voltage, temperature)
DS2436 (3) DS2437 (3) DS2438 (3) DS2751 (3) DS2755 (3) DS2756 (3) DS2760 (3) DS2770 (3) DS2780 (3) DS2781 (3) DS2788 (3) DS2784 (3)
Counter
DS2423 (3)
LCD Screen
LCD (3) DS2408 (3)
Crypto
DS1977 (3)
Pressure
DS2406 (3) TAI8570 (3) EDS0066 (3) EDS0068 (3)
Moisture
EEEF (3) DS2438 (3)
AVAILABILITY
AUTHOR
Paul Alfille ([email protected])