zr_inventory_test - openconfig/featureprofiles GitHub Wiki
Validate 400ZR modules report correct inventory information.
-
Plug in the ZR module in the host port and make sure the transceiver state is enabled and host is able to detect the module.
-
With the module recognized verify it reports correct inventory information by subscribing ON_CHANGE to the following telemetry paths.
- /platform/components/component/state/serial-no
- /platform/components/component/state/part-no
- /platform/components/component/state/type
- /platform/components/component/state/description
- /platform/components/component/state/mfg-name
- /platform/components/component/state/mfg-date
- /platform/components/component/state/hardware-version
- /platform/components/component/state/firmware-version
-
Validate the streamed inventory information data is of type String.
-
Verify that the modules inventory information is reported correctly after an optic software reset.
- With ZR module plugged in the host and properly recognized
- Verify the ZR optics inventory is correctly reported via the streaming telemetry paths above.
- Reset the optic by enabling and disabling the transceiver state through /components/component/transceiver/config/enabled.
- Wait at least 20 seconds in between toggling transceiver state.
- Verify the ZR optics still reports correct inventory information.
- Telemetry subscription should be ON_CHANGE and streamed data should be of type String.
-
Verify that the modules inventory information is reported correctly when interface state is disabled.
- With ZR module plugged in the host and properly recognized
- Use /interfaces/interface/config/enabled to disable the module interface state, wait 20 seconds.
- Verify the ZR optics inventory information is correctly reported via the streaming telemetry paths above in this state.
- Telemetry subscription should be ON_CHANGE and streamed data should be of type String.
-
Verify the module behaviour and related inventory information when transceiver state is set to disabled.
- With ZR module plugged in the host and properly recognized.
- Use /components/component/transceiver/config/enabled to disable the module transceiver state, wait 20 seconds.
- Verify the ZR module is powered off and no inventory information reported via the streaming telemetry paths above in this state.
- When a component is powered off and is dropped from the inventory list explicit deletes for the relevant entity leaves should be streamed to clear any stale data.
- Telemetry subscription should be ON_CHANGE and there should be no streamed inventory data in this state.
-
Verify the module inventory information updates when transceiver under test is swapped with a different one.
- Make sure ZR module plugged in the host and properly recognized.
- Verify module is reporting valid inventory information.
- Swap the module with a different one and validate that the new inventory information is correctly streamed now.
- Telemetry subscription should be ON_CHANGE and streamed data should be of type String.
- /components/component/transceiver/config/enabled
- /interfaces/interface/config/enabled
- /platform/components/component/state/serial-no
- /platform/components/component/state/part-no
- /platform/components/component/state/type
- /platform/components/component/state/description
- /platform/components/component/state/mfg-name
- /platform/components/component/state/mfg-date
- /platform/components/component/state/hardware-version
- /platform/components/component/state/firmware-version
rpcs:
gnmi:
gNMI.Get:
gNMI.Set:
gNMI.Subscribe: