Validate that the P4RT server can accept basic configuration and Read/Write RPCs.
-
Connect ATE port-1 to DUT port-1, and ATE port-2 to DUT port-2.
-
Configure P4RT id and node-id with two different interfaces on different FAPs.
-
Send the WBB P4Info via the SetForwardingConfigPipeline.
-
Send RPC Write to install the WBBIngressaclTable for GDP, LLDP and traceroute with meters attached.
-
Verify if the RPC write is success.
-
Send RPC Read to read back the installed table entries.
-
Validate the read Response for each of table entries GDP, LLDP and traceroute.
-
Repeat the same steps for another FAP and verify the Table entries.
paths:
/components/component/integrated-circuit/config/node-id:
platform_type: ["INTEGRATED_CIRCUIT"]
/interfaces/interface/config/id:
rpcs:
gnmi:
gNMI.Get:
gNMI.Set:
gNMI.Subscribe: