LoadRunner controller application

Result processing settings need to be set as follows:

Results ->
disable (tick off if not already): Auto Load Analysis
enable (tick on if not already): Auto Collate Results

To be certain that the resulting Access database (.mdb) is generated from "Complete data" (see bottom right corner of application when opening LoadRunner results) it is recommended that the follow option is set:

Tools -> Options... -> tab Result Collection -> Datasource: Generate complete data only
Tools -> Options... -> tab Result Collection -> Data Aggregation: Apply user-defined aggregation -> Aggregation Confguration button -> Web data aggregation only radio button & value of 1 second

Next a default template has to be created in LoadRunner analysis application with the following properties:

Tools -> Templates -> (new or default template) ->
enable (tick on): Automatically save the session as: %ResultDir%\LRA
enable (tick on): Automatically close Analysis after saving session