NI RFmx LTE SlotPower Attributes - ni/grpc-device GitHub Wiki
- RFMXLTE_ATTR_SLOTPOWER_MEASUREMENT_ENABLED
- RFMXLTE_ATTR_SLOTPOWER_MEASUREMENT_OFFSET
- RFMXLTE_ATTR_SLOTPOWER_MEASUREMENT_LENGTH
- RFMXLTE_ATTR_SLOTPOWER_COMMON_CLOCK_SOURCE_ENABLED
- RFMXLTE_ATTR_SLOTPOWER_SPECTRUM_INVERTED
- RFMXLTE_ATTR_SLOTPOWER_ALL_TRACES_ENABLED
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to enable the SlotPower measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_FALSE. Get Function: RFmxLTE_SlotPowerGetMeasurementEnabled Set Function: RFmxLTE_SlotPowerSetMeasurementEnabled |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies the measurement offset to skip from the frame boundary or the marker (external trigger) location. This value is expressed in subframe. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 0. Get Function: RFmxLTE_SlotPowerGetMeasurementOffset Set Function: RFmxLTE_SlotPowerSetMeasurementOffset |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies the number of subframes to be measured. This value is expressed in subframe. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is 10. Get Function: RFmxLTE_SlotPowerGetMeasurementLength Set Function: RFmxLTE_SlotPowerSetMeasurementLength |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether the same Reference Clock is used for the local oscillator and the digital-to-analog converter in the transmitter. When the same Reference Clock is used, the carrier frequency offset is proportional to Sample Clock error. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_SLOTPOWER_COMMON_CLOCK_SOURCE_ENABLED_TRUE. Get Function: RFmxLTE_SlotPowerGetCommonClockSourceEnabled Set Function: RFmxLTE_SlotPowerSetCommonClockSourceEnabled |
Values: |
RFMXLTE_VAL_SLOTPOWER_COMMON_CLOCK_SOURCE_ENABLED_FALSE (0) | The Sample Clock error is estimated independently. |
---|---|
RFMXLTE_VAL_SLOTPOWER_COMMON_CLOCK_SOURCE_ENABLED_TRUE (1) | The Sample Clock error is estimated from carrier frequency offset. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether the spectrum of the measured signal is inverted. The inversion happens when the I and the Q components of the baseband complex signal are swapped. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_SLOTPOWER_SPECTRUM_INVERTED_FALSE. Get Function: RFmxLTE_SlotPowerGetSpectrumInverted Set Function: RFmxLTE_SlotPowerSetSpectrumInverted |
Values: |
RFMXLTE_VAL_SLOTPOWER_SPECTRUM_INVERTED_FALSE (0) | The spectrum of the measured signal is not inverted. |
---|---|
RFMXLTE_VAL_SLOTPOWER_SPECTRUM_INVERTED_TRUE (1) | The measured signal is inverted and the measurement corrects the signal by swapping the I and the Q components. |
Data Type: | int32 |
---|---|
Access: | read/write |
Functions: | RFmxLTE_SetAttributeI32 RFmxLTE_GetAttributeI32 |
Description: | Specifies whether to enable the traces to be stored and retrieved after performing the SlotPower measurement. You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals. The default value is RFMXLTE_VAL_FALSE. Get Function: RFmxLTE_SlotPowerGetAllTracesEnabled Set Function: RFmxLTE_SlotPowerSetAllTracesEnabled |