NI RFSA Factory Calibration Attributes - ni/grpc-device GitHub Wiki

Factory Calibration Attributes

NI 5601

NIRFSA_ATTR_CAL_RF_PATH_SELECTION

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Specifies the RF path to use during calibration. This attribute is valid only during a calibration session. When you set this attribute, NI-RFSA does not select the RF path based on the downconverter center frequency.

The following table lists the RF bands used by the supported devices.

Device RF Band Frequency Range
PXIe-5603 RF band 1 20 Hz to 3.6 GHz
PXIe-5605 (low band signal path) RF band 1 20 Hz to 3.6 GHz
PXIe-5605 (high band signal path) RF band 2 3.6 GHz to 14 GHz
PXIe-5606 (low band signal path) RF band 1 20 Hz to 3.6 GHz
PXIe-5606 (high band signal path) RF band 2 3.6 GHz to 26.5 GHz
PXIe-5606 (low band signal path, 320 MHz IF filter) RF band 1 20 Hz to 3.41 GHz
PXIe-5606 (high band signal path, 320 MHz IF filter) RF band 2 3.41 GHz to 26.5 GHz
Defined and Valid Values:
Value Description Valid For
NIRFSA_VAL_EXT_CAL_RF_BAND_1 (1700)    Specifies to use RF band 1. PXIe-5601/5603/5605/5606
NIRFSA_VAL_EXT_CAL_RF_BAND_2 (1701) Specifies to use RF band 2. PXIe-5601/5605/5606
NIRFSA_VAL_EXT_CAL_RF_BAND_3 (1702) Specifies to use RF band 3. PXIe-5601
NIRFSA_VAL_EXT_CAL_RF_BAND_4 (1703) Specifies to use RF band 4. PXIe-5601
Default Values:

PXIe-5603/5605 (low band)/5606—NIRFSA_VAL_EXT_CAL_RF_BAND_1

PXIe-5601/5605 (high band)—NIRFSA_VAL_EXT_CAL_RF_BAND_2

Supported Devices: PXIe-5601/5603/5605/5606, PXIe-5698

NI 5665/5668R

NIRFSA_ATTR_CAL_RF_PATH_SELECTION

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Specifies the RF path to use during calibration. This attribute is valid only during a calibration session. When you set this attribute, NI-RFSA does not select the RF path based on the downconverter center frequency.

The following table lists the RF bands used by the supported devices.

Device RF Band Frequency Range
PXIe-5603 RF band 1 20 Hz to 3.6 GHz
PXIe-5605 (low band signal path) RF band 1 20 Hz to 3.6 GHz
PXIe-5605 (high band signal path) RF band 2 3.6 GHz to 14 GHz
PXIe-5606 (low band signal path) RF band 1 20 Hz to 3.6 GHz
PXIe-5606 (high band signal path) RF band 2 3.6 GHz to 26.5 GHz
PXIe-5606 (low band signal path, 320 MHz IF filter) RF band 1 20 Hz to 3.41 GHz
PXIe-5606 (high band signal path, 320 MHz IF filter) RF band 2 3.41 GHz to 26.5 GHz
Defined and Valid Values:
Value Description Valid For
NIRFSA_VAL_EXT_CAL_RF_BAND_1 (1700)    Specifies to use RF band 1. PXIe-5601/5603/5605/5606
NIRFSA_VAL_EXT_CAL_RF_BAND_2 (1701) Specifies to use RF band 2. PXIe-5601/5605/5606
NIRFSA_VAL_EXT_CAL_RF_BAND_3 (1702) Specifies to use RF band 3. PXIe-5601
NIRFSA_VAL_EXT_CAL_RF_BAND_4 (1703) Specifies to use RF band 4. PXIe-5601
Default Values:

PXIe-5603/5605 (low band)/5606—NIRFSA_VAL_EXT_CAL_RF_BAND_1

PXIe-5601/5605 (high band)—NIRFSA_VAL_EXT_CAL_RF_BAND_2

Supported Devices: PXIe-5601/5603/5605/5606, PXIe-5698

NIRFSA_ATTR_CAL_RF_ELECTRONIC_ATTENUATION_INDEX

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Selects the value of RF electronic attenuation from a table of valid configurations. This attribute is valid only during a calibration session and when you set the NIRFSA_ATTR_CAL_RF_PATH_SELECTION attribute to NIRFSA_ATTR_VAL_EXT_CAL_RF_BAND_1.

Default Value: N/A

Supported Devices: PXIe-5603/5605/5606

NIRFSA_ATTR_CAL_RF_MECHANICAL_ATTENUATION_INDEX

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Selects the value of the RF mechanical attenuation configuration from a table of valid configurations. This attribute is valid only during a calibration session.

Default Values:

PXIe-5603/5605: 3

PXIe-5606: 2

Supported Devices: PXIe-5603/5605/5606

NIRFSA_ATTR_CAL_IF_FILTER_SELECTION

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Specifies the IF filter path during calibration. The attribute is valid only during a calibration session.

Defined Values:

NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_1 (2100)    Specifies that the 5 MHz filter path is used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_2 (2101) Specifies that the 300 kHz filter path is used during calibration. Not supported for the PXIe-5694.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_3 (2102) None of the IF filter paths are used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_4 (2103) Specifies that the 20 MHz filter path is used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_5 (2104) Specifies that the 1.4 MHz filter path is used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_6 (2105) Specifies that the 400 kHz filter path is used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_7 (2106) Specifies that the 110 kHz filter path is used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_8 (2107) Specifies that the 30 kHz filter path is used during calibration.
Default Value: NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_4

Supported Devices: PXIe-5694

NIRFSA_ATTR_CAL_IF_ATTENUATION_TABLE_SELECTION

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Specifies the IF attenuation table to be used for external calibration. This attribute is valid only in a calibration session.

Defined Values:

NIRFSA_VAL_EXT_CAL_IF_ATTENUATION_TABLE_STANDARD (2900)    Specifies that the standard IF attenuation table is used for the external calibration.
NIRFSA_VAL_EXT_CAL_IF_ATTENUATION_TABLE_ACPR (2901) Specifies that the adjacent channel power ratio (ACPR) IF attenuation table is used for the external calibration. You can only select this value if you set the NIRFSA_ATTR_CAL_IF_FILTER_SELECTION attribute to NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_1 or NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_2.
Default Value: NIRFSA_VAL_EXT_CAL_IF_ATTENUATION_TABLE_STANDARD

Supported Devices: PXIe-5603/5605

NIRFSA_ATTR_CAL_IF_ATTENUATION_INDEX

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Specifies the IF attenuation index from a table of valid settings. To select a correct attenuation table, set this attribute in conjunction with the NIRFSA_ATTR_CAL_IF_FILTER_SELECTION attribute. This attribute is valid only during a calibration session.

Valid Values: 0 to 25

Default Value: 0

Supported Devices: PXIe-5694

NIRFSA_ATTR_CAL_LO_PATH_SELECTION

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Selects the LO signal path used during calibration. During noncalibration sessions, NI-RFSA implicitly derives the LO signal path from the center frequency. During calibration sessions, you must explicitly specify the LO signal path. This attribute is valid only during a calibration session.

Defined Values:

NIRFSA_VAL_EXT_CAL_LO_PATH_1 (2300)    Specifies that the LO path 1 is used.    
NIRFSA_VAL_EXT_CAL_LO_PATH_2 (2301) Specifies that the LO path 2 is used.
NIRFSA_VAL_EXT_CAL_LO_PATH_3 (2302) Specifies that the LO path 3 is used.
NIRFSA_VAL_EXT_CAL_LO_PATH_4 (2303) Specifies that the LO path 4 is used.
NIRFSA_VAL_EXT_CAL_LO_PATH_5 (2304) Specifies that the LO path 5 is used.
Default Value: NIRFSA_VAL_EXT_CAL_LO_PATH_1

Supported Devices: PXIe-5603/5605/5606

NIRFSA_ATTR_CAL_LO1_ATTENUATION

Specific Attribute

Data
type
Access High Level Functions
ViReal64 R/W None

Description

Specifies the LO1 attenuation, in dB, during a calibration session. This attribute is valid only during a calibration session.

Valid Values and Default Values:

Device Valid Values Default Value
PXIe-5603/5605 0 to 15.5 15.5
PXIe-5606 0 to 31 31
Supported Devices: PXIe-5603/5605/5606

NIRFSA_ATTR_CAL_LO2_ATTENUATION

Specific Attribute

Data
type
Access High Level Functions
ViReal64 R/W None

Description

Specifies the LO2 attenuation, in dB, during a calibration session. This attribute is valid only during a calibration session.

Valid Values and Default Values:

Device Valid Values Default Value
PXIe-5603/5605 0 to 15.5 15.5
PXIe-5606 0 to 31 31
Supported Devices: PXIe-5603/5605/5606

NIRFSA_ATTR_CAL_LO3_ATTENUATION

Specific Attribute

Data
type
Access High Level Functions
ViReal64 R/W None

Description

Specifies the LO3 attenuation, in dB, during a calibration session. This attribute is valid only during a calibration session.

Valid Values and Default Values:

Device Valid Values Default Value
PXIe-5603/5605 0 to 15.5 15.5
PXIe-5606 0 to 31 31
Supported Devices: PXIe-5603/5605/5606

NIRFSA_ATTR_CAL_IF_ATTENUATION_TABLE_SIZE

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R None

Description

Returns the size of the selected IF attenuation table.

Valid Values: 0-132

Default Value: 0

Supported Devices: PXIe-5606

NIRFSA_ATTR_CAL_RF_LOWBAND_SIGNAL_CONDITIONING_PATH_SELECTION

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Specifies the RF lowband signal conditioning path.

Valid Values: NIRFSA_VAL_EXT_CAL_RF_LOWBAND_CONDITIONING_PATH_1, NIRFSA_VAL_EXT_CAL_RF_LOWBAND_CONDITIONING_PATH_2

Default Value: NIRFSA_VAL_EXT_CAL_RF_LOWBAND_CONDITIONING_PATH_1

Supported Devices: PXIe-5606

NI 5693

NIRFSA_ATTR_CAL_TONE_STEP_ATTENUATION

Specific Attribute

Data
type
Access High Level Functions
ViReal64 R/W None

Description

Specifies the step attenuator to engage in the calibration tone path.

Units: dB

Valid Values: 2.00, 10.00

Default Value: 2.00 dB

Supported Devices: PXIe-5693

NIRFSA_ATTR_RF_ATTENUATION_INDEX

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Specifies the value of the RF attenuation from a table of valid configurations. This attribute is valid only during a calibration session and when you set the NIRFSA_ATTR_LOW_FREQUENCY_BYPASS_ENABLED attribute to NIRFSA_VAL_DISABLED.

Valid Values: 0 to 64

Default Value: N/A

Supported Devices: PXIe-5693

NI 5694

NIRFSA_ATTR_CAL_IF_FILTER_SELECTION

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Specifies the IF filter path during calibration. The attribute is valid only during a calibration session.

Defined Values:

NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_1 (2100)    Specifies that the 5 MHz filter path is used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_2 (2101) Specifies that the 300 kHz filter path is used during calibration. Not supported for the PXIe-5694.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_3 (2102) None of the IF filter paths are used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_4 (2103) Specifies that the 20 MHz filter path is used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_5 (2104) Specifies that the 1.4 MHz filter path is used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_6 (2105) Specifies that the 400 kHz filter path is used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_7 (2106) Specifies that the 110 kHz filter path is used during calibration.
NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_8 (2107) Specifies that the 30 kHz filter path is used during calibration.
Default Value: NIRFSA_VAL_EXT_CAL_IF_FILTER_PATH_4

Supported Devices: PXIe-5694

NIRFSA_ATTR_CAL_IF_ATTENUATION_INDEX

Specific Attribute

Data
type
Access High Level Functions
ViInt32 R/W None

Description

Specifies the IF attenuation index from a table of valid settings. To select a correct attenuation table, set this attribute in conjunction with the NIRFSA_ATTR_CAL_IF_FILTER_SELECTION attribute. This attribute is valid only during a calibration session.

Valid Values: 0 to 25

Default Value: 0

Supported Devices: PXIe-5694

⚠️ **GitHub.com Fallback** ⚠️