wake current - malvira/th-12 GitHub Wiki

Wake Current measurments:

Measured with a current probe with Vbatt= 3V.

Cal factor: 536mV = 10.57mA

wake current wake detail

Length (ms) Height (mV) current (mA)
180 312 6.153
700 40 0.789
340 64 1.262
960 0.060
82 888 17.511
7 1220 24.059
39 888 17.511
117770 0.010

For a 120sec sample period, the average current is 46.7uA.

Spreadsheet with these calcs: current spreadsheet

Average current for other sample periods. Run life is based on a conservative 1600mAh battery rating (2400mV end voltage; see discarge test):

Period (s) Avg. Current (uA) Run Life (days) Run life (years)
10 447.6 149 0.41
30 156.6 426 1.17
60 83.4 799 2.19
120 46.7 1427 3.91
300 24.7 2699 7.40
600 17.3 3842 10.53

Note that the self-life of an alkaline cell is typically 7 years. Therefore a sample period much greater than 5mins probably doesn't increase run-life significantly. These estimates do not consider self-discharge effects of the cell. Self discharge is rated in percent capacity per month. A reasonable model therefore might be an added 15 to 20uA average over the runtime of the cell. Considering 15uA self discharge, the following table can be used. Note the 5yr variance on the low duty ratio number. Accurately characterizing self-discharge is necessary to computing run-life with reasonable confidence.

Period (s) Avg. Current (uA) Run Life (days) Run life (years)
10 447.6 144 0.39
30 156.6 388 1.06
60 83.4 677 1.86
120 46.7 1080 2.96
300 40 1679 4.60
600 32 2061 5.65
⚠️ **GitHub.com Fallback** ⚠️