Error list - makerbase-mks/MKS-SERVO42C GitHub Wiki

  • err1: “Not Cal”

    the motor need to be calibrated. Click “Cal” for motor calibration.

  • err2 “Waiting V+ Power!”

    the motor has not power on,please connect the V+ pin to power.

  • err3“Offset Current Error!”

    reserved.

  • err4“Phase Line Error!”

    if it keeps show “Phase Line Error”,please adjust the 4pin motor cable wiring sequence.

  • err5“Reverse Lookup Error!”

    if it keeps show “Phase Line Error”,please adjust the 4pin motor cable wiring sequence.

  • err6 “Magnet Loss! Enter..”

    please check the magnet is stuck in the middle of the motor shaft.

  • err7 “Magnet Error! Enter..”

    reserved.

  • err8 “Motor Type Error!”

    Motor type (0.9°/1.8°) detects error.

    Maybe the motor calibrated is on load, or the motor shaft was stuck with too much glue.

  • err9 “Coming Back to Origin..”

    Just waiting for the motor go back to the zero point.

  • err10“Back to Origin Fail!!!”

    Maybe the motor shaft is block when go back to zero point .

    Or 0_Mode is set to “NearMode”,and the screen show “Back to Origin Fail!!!”.,please set 0_Dir to “CCW”,and try it again.

  • err11“Wrong Protect Enter..”

    the motor shaft is blocking. Please power off and check the load.