err1: “Not Cal”
the motor need to be calibrated. Click “Cal” for motor calibration.
-
err2 “Waiting V+ Power!”
the motor has not power on,please connect the V+ pin to power.
-
err3“Offset Current Error!”
reserved.
-
err4“Phase Line Error!”
if it keeps show “Phase Line Error”,please adjust the 4pin motor cable wiring sequence.
-
err5“Reverse Lookup Error!”
if it keeps show “Phase Line Error”,please adjust the 4pin motor cable wiring sequence.
-
err6 “Magnet Loss! Enter..”
please check the magnet is stuck in the middle of the motor shaft.
-
err7 “Magnet Error! Enter..”
reserved.
-
err8 “Motor Type Error!”
Motor type (0.9°/1.8°) detects error.
Maybe the motor calibrated is on load, or the motor shaft was stuck with too much glue.
-
err9 “Coming Back to Origin..”
Just waiting for the motor go back to the zero point.
-
err10“Back to Origin Fail!!!”
Maybe the motor shaft is block when go back to zero point .
Or 0_Mode is set to “NearMode”,and the screen show “Back to Origin Fail!!!”.,please set 0_Dir to “CCW”,and try it again.
-
err11“Wrong Protect Enter..”
the motor shaft is blocking. Please power off and check the load.