IBM ‐ Factory Reset S822L - kth5/archpower GitHub Wiki

This will perform a full factory reset of a IBM S822L (potentially other machines) using only physical pull-out control panel. Coincidentally, this also removes all HMC, networking and password configurations and resets them to their respective defaults. We log it here because it was a lot of work to find this, it's immensely useful when you get a used one second hand and most of the time aren't provided with all credentials.

  • use function 02 to set the service coprocessor into manual mode, enabling functions 25 and 26
    • use function 25, push OK to reveal "25 00"
    • use function 26, push OK to reveal "26 00"
  • you have now enabled the customer-extended functions (if you see "26 FF", just try again)
  • use function 73 (reset system)
    • push OK to reveal "A170800B"
    • push OK to "reveal 73"
    • push OK one last time
  • wait 5 minutes for reset to complete
  • once you see default screen with "01 PVM" etc, the reset was successful
  • use function 02 to set the service coprocessor into manual mode
    • use function 3000 and 3001 to reveal ASMI IP address
  • now log in as admin/admin via serial
  • the menu will initially only show change password