Insteon is a home area networking technology developed primarily for connecting light switches and loads. Insteon devices send messages either via the power line, or by means of radio frequency (RF) waves, or both (dual-band). A considerable number of Insteon compatible devices such as switchable relays, thermostats, sensors etc are available. More about Insteon can be found on Wikipedia.

This binding provides access to the Insteon network by means of an Insteon PowerLinc Modem (PLM). The modem can be connected to the openHAB server either via a serial port (Model 2413S) or a USB port (Model 2413U). The binding translates openHAB commands into Insteon messages and sends them on the Insteon network. Relevant messages from the Insteon network (like notifications about switches being toggled) are picked up by the modem and converted to openHAB status updates by the binding.

Insteon devices

Every Insteon device type is uniquely identified by its Insteon product key, a six digit hex number. For some of the older device types (in particular the SwitchLinc switches and dimmers), Insteon does not give a product key, so an arbitrary fake one of the format Fxx.xx.xx is assigned by the binding.

Finally, each Insteon device comes with a hard-coded Insteon address that can be found on a label on the device. This address should be recorded for every device in the network, as it is a mandatory part of the binding configuration string.

The following devices have been tested and should work out of the box:

Model Description Product Key Comments tested by
2477D SwitchLinc Dimmer F00.00.01 Bernd Pfrommer
2477S SwitchLinc Switch F00.00.02 Bernd Pfrommer
2845-222 Hidden Door Sensor F00.00.03 Benido Josenivaldo
2876S ICON Switch F00.00.04 Patrick Giasson
2456D3 LampLinc V2 F00.00.05 Patrick Giasson
2442-222 Micro Dimmer F00.00.06 Benido Josenivaldo
2453-222 DIN Rail On/Off F00.00.07 Benido Josenivaldo
2452-222 DIN Rail Dimmer F00.00.08 Benido Josenivaldo
2458-A1 MorningLinc RF Lock Controller F00.00.09 Read the instructions very carefully: Sync with lock within 5 feet to avoid bad connection, link twice for both ON and OFF functionality. cdeadlock
2852-222 Leak Sensor F00.00.0A Kirk McCann
2672-422 LED Dimmer F00.00.0B
2476D SwitchLinc Dimmer F00.00.0C LiberatorUSA
2634-222 On/Off Dual-Band Outdoor Module F00.00.0D LiberatorUSA
2342-2 Mini Remote F00.00.10 Bernd Pfrommer
2450 IO Link 0x00001A Bernd Pfrommer
2486D KeypadLinc Dimmer 0x000037 Patrick Giasson, Joe Barnum
2413U PowerLinc 2413U USB modem 0x000045 Bernd Pfrommer
2843-222 Wireless Open/Close Sensor 0x000049 Benido Josenivaldo
2842-222 Motion Sensor 0x00004A Bernd Pfrommer
2486DWH8 KeypadLinc Dimmer 0x000051 Chris Graham
2472D OutletLincDimmer 0x000068 Chris Graham

Insteon binding process

Before Insteon devices communicate with one another, they must be linked. During the linking process, one of the devices will be the "Controller", the other the "Responder" (see e.g. the SwitchLinc Instructions).

The responder listens to messages from the controller, and reacts to them. Note that except for the case of a motion detector (which is just a controller to the modem), the modem controls the device (e.g. send on/off messages to it), and the device controls the modem (so the modem learns about the switch being toggled). For this reason, most devices and in particular switches/dimmers should be linked twice, with one taking the role of controller during the first linking, and the other acting as controller during the second linking process. To do so, first press and hold the "Set" button on the modem until the light starts blinking. Then press and hold the "Set" button on the remote device, e.g. the light switch, until it double beeps (the light on the modem should go off as well). Now do exactly the reverse: press and hold the "Set" button on the remote device until its light starts blinking, then press and hold the "Set" button on the modem until it double beeps, and the light of the remote device (switch) goes off. Done.

Installation and Configuration

The binding does not support linking new devices on the fly, i.e. all devices must be linked with the modem before starting the InsteonPLM binding. Each device has an Insteon address of the format 'xx.xx.xx' which can usually be found on a label on the device.

  1. Copy the binding (e.g. openhab.binding.insteonplm-<version>.jar into the openhab/addons folder
  2. Edit the relevant section in the openhab configuration file (openhab/configurations/openhab.cfg). Note that while multiple modems are possible, the binding has never been tested for more than one modem!
  3. Add configuration information to the .items file (see below)
  4. Optional: configure for debug logging into a separate file (see trouble shooting section)

Item Binding Configuration

Since Insteon devices can have multiple features (for instance a switchable relay and a contact sensor) under a single Insteon address, an openHAB item is not bound to a device, but to a given feature of a device:

insteonplm="<insteon_address>:<product_key>#feature[,<parameter>=value, ...]>"

The following lines in your insteonplm.items file would configure a light switch, a dimmer, a motion sensor, and a garage door opener with contact sensor, a front door lock, and a button of a mini remote:

Switch officeLight "office light" (office,lights) {insteonplm="24.02.dc:F00.00.02#switch"}
Dimmer kitchenChandelier "kitchen chandelier" (kitchen,lights) {insteonplm="20.c4.43:F00.00.01#dimmer"}
Contact garageMotionSensor "motion sensor [MAP(contact.map):%s]" (garage,contacts) {insteonplm="27.8c.c3:0x00004A#contact"}
Switch garageDoorOpener "garage door opener" <garagedoor>  (garage,openers) {insteonplm="28.c3.f1:0x00001A#switch"}
Contact garageDoorContact "garage door contact [MAP(contact.map):%s]" (garage,contacts)     {insteonplm="28.c3.f1:0x00001A#contact"}
Switch frontDoorLock "Front Door [MAP(lock.map):%s]" {insteonplm="xx.xx.xx:F00.00.09#switch"}
Switch miniRemoteContactButton1	    "mini remote button 1" (garage,lights){insteonplm="2e.7c.9a:F00.00.02#switch,button=1"}

Note the use of a MAP(contact.map), which should go into the transforms directory and look like this:

OPEN=open
CLOSED=closed
-=unknown

'MAP(lock.map)`, which should go into the transforms directory and look like this:

ON=Lock
OFF=Unlock
-=unknown

If you have a garage door opener, see the I/O Linc documentation for the meaning of the momentary keyword (not supported/needed for other devices).

Removing devices from the Modem's link database

When an Insteon device breaks or is no longer needed, it should be removed from them modem's link database. Since this is particularly tricky if the device is no longer operable, the binding has a rudimentary feature to eliminate entries: Instantiate a Switch item in the .items file, referencing the modem with its proper Insteon address:

Switch removeAddress		    "switch to remove address"	  	(gControllers)			{insteonplm="1E.DB.41:0x000045#control,remove_address=2e.7c.9a"}

In the binding config, a control feature is referenced, and the address of the device to be removed from the modem is passed as parameter remove_address. Toggling the switch to ON will send a command to the modem, erasing the db entry.

Trouble shooting

To get additional debugging information, insert the following into your logback.xml file:

<appender name="INSTEONPLMFILE" class="ch.qos.logback.core.rolling.RollingFileAppender">
    <file>logs/insteonplm.log</file>
    <rollingPolicy class="ch.qos.logback.core.rolling.TimeBasedRollingPolicy">
            <fileNamePattern>logs/insteonplm-%d{yyyy-ww}.log.zip</fileNamePattern>
    <maxHistory>30</maxHistory>
    </rollingPolicy>
    <encoder>
            <pattern>%d{yyyy-MM-dd HH:mm:ss} %-5level %logger{30}[:%line]- %msg%n%ex{5}</pattern>
    </encoder>
</appender>
<!-- Change DEBUG->TRACE for even more detailed logging -->
<logger name="org.openhab.binding.insteonplm" level="DEBUG" additivity="false">
<appender-ref ref="INSTEONPLMFILE" />
</logger>

This will log additional debugging messages to a separate file in the log directory.

Adding new device types (using existing device features)

Device types are defined in the file device_types.xml, which is inside the InsteonPLM bundle and thus not visible to the user. You can however load your own device_types.xml by referencing it in the openhab.cfg file like so:

insteonplm:more_devices=/usr/local/openhab/rt/my_own_devices.xml

Where the my_own_devices.xml file defines a new device like this:

<xml>
 <device productKey="F00.00.XX">
  <model>2456-D3</model>
  <description>LampLinc V2</description>
  <feature name="dimmer">GenericDimmer</feature>
  <feature name="lastheardfrom">GenericLastTime</feature>
 </device>
</xml>

Finding the Insteon product key can be tricky since Insteon has not updated the product key table (http://www.insteon.com/pdf/insteon_devcats_and_product_keys_20081008.pdf) since 2008. If a web search does not turn up the product key, make one up, starting with "F", like: F00.00.99. Avoid duplicate keys by finding the highest fake product key in the device_types.xml file, and incrementing by one.

Adding new device features

If you can't can't build a new device out of the existing device features (for a complete list see device_features.xml) you can add new features by specifying a file (let's call it my_own_features.xml) with the "more_devices" option in the openhab.cfg file:

insteonplm:more_features=/usr/local/openhab/rt/my_own_features.xml

In this file you can define your own features (or even overwrite an existing feature). In the example below a new feature "MyFeature" is defined, which can then be referenced from the device_types.xml file (or from my_own_devices.xml): DefaultDispatcher NoOpMsgHandler NoOpMsgHandler NoOpMsgHandler NoOpMsgHandler LightStateSwitchHandler IOLincOnOffCommandHandler DefaultPollHandler

If you cannot cobble together a suitable device feature out of existing handlers you will have to define new ones by editing the corresponding Java classes in the source tree (see below).

Adding new handlers (for developers experienced with Eclipse IDE)

If all else fails there are the Java sources, in particular the classes MessageHandler.java (what to do with messages coming in from the Insteon network), PollHandler.java (how to form outbound messages for device polling), and CommandHandler.java (how to translate openhab commands to Insteon network messages). To that end you'll need to become a bonafide openHAB developer, and set up an openHAB Eclipse build environment, following the online instructions.

Known Limitations and Issues

  1. Devices cannot be linked to the modem while the binding is running. If new devices are linked, the binding must be restarted.
  2. Very rarely during binding startup, a message arrives at the modem while the initial read of the modem database happens. Somehow the modem then stops sending the remaining link records and the binding no longer is able to address the missing devices. The fix is to simply restart the binding.