Invoke ADCUnsetAppflowcollector - j81blog/J81.ADCToolkit GitHub Wiki

Invoke-ADCUnsetAppflowcollector

SYNOPSIS

Unset Appflow configuration Object.

SYNTAX

Invoke-ADCUnsetAppflowcollector [[-Name] <String>] [[-ipaddress] <Boolean>] [[-port] <Boolean>]
 [[-netprofile] <Boolean>] [-WhatIf] [-Confirm] [<CommonParameters>]

DESCRIPTION

Configuration for AppFlow collector resource.

EXAMPLES

EXAMPLE 1

Invoke-ADCUnsetAppflowcollector -name <string>

An example how to unset appflowcollector configuration Object(s).

PARAMETERS

-Name

Name for the collector. Must begin with an ASCII alphabetic or underscore (_) character, and must contain only ASCII alphanumeric, underscore, hash (#), period (.), space, colon (:), at (@), equals (=), and hyphen (-) characters. Only four collectors can be configured.

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: 2
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-ipaddress

IPv4 address of the collector.

Type: Boolean
Parameter Sets: (All)
Aliases:

Required: False
Position: 3
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-port

Port on which the collector listens.

Type: Boolean
Parameter Sets: (All)
Aliases:

Required: False
Position: 4
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-netprofile

Netprofile to associate with the collector. The IP address defined in the profile is used as the source IP address for AppFlow traffic for this collector. If you do not set this parameter, the Citrix ADC IP (NSIP) address is used as the source IP address.

Type: Boolean
Parameter Sets: (All)
Aliases:

Required: False
Position: 5
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Confirm

Prompts you for confirmation before running the cmdlet.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

INPUTS

OUTPUTS

NOTES

File Name : Invoke-ADCUnsetAppflowcollector Version : v2111.2521 Author : John Billekens Reference : https://developer-docs.citrix.com/projects/citrix-adc-nitro-api-reference/en/latest/configuration/appflow/appflowcollector Requires : PowerShell v5.1 and up ADC 13.x and up. ADC 12 and lower may work, not guaranteed.

RELATED LINKS

https://blog.j81.nl

⚠️ **GitHub.com Fallback** ⚠️