Invoke ADCAddServicelbmonitorbinding - j81blog/J81.ADCToolkit GitHub Wiki

Invoke-ADCAddServicelbmonitorbinding

SYNOPSIS

Add Basic configuration Object.

SYNTAX

Invoke-ADCAddServicelbmonitorbinding [-Name] <String> [[-Monitor_name] <String>] [[-Monstate] <String>]
 [[-Weight] <Double>] [[-Passive] <Boolean>] [-PassThru] [-WhatIf] [-Confirm] [<CommonParameters>]

DESCRIPTION

Binding object showing the lbmonitor that can be bound to service.

EXAMPLES

EXAMPLE 1

Invoke-ADCAddServicelbmonitorbinding -name <string>

An example how to add service_lbmonitor_binding configuration Object(s).

PARAMETERS

-Name

Name of the service to which to bind a monitor.

Type: String
Parameter Sets: (All)
Aliases:

Required: True
Position: 2
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Monitor_name

The monitor Names.

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: 3
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Monstate

The configured state (enable/disable) of the monitor on this server. Possible values = ENABLED, DISABLED

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: 4
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Weight

Weight to assign to the monitor-service binding. When a monitor is UP, the weight assigned to its binding with the service determines how much the monitor contributes toward keeping the health of the service above the value configured for the Monitor Threshold parameter.

Type: Double
Parameter Sets: (All)
Aliases:

Required: False
Position: 5
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-Passive

Indicates if load monitor is passive. A passive load monitor does not remove service from LB decision when threshold is breached.

Type: Boolean
Parameter Sets: (All)
Aliases:

Required: False
Position: 6
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-PassThru

Return details about the created service_lbmonitor_binding item.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Confirm

Prompts you for confirmation before running the cmdlet.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

INPUTS

OUTPUTS

NOTES

File Name : Invoke-ADCAddServicelbmonitorbinding Version : v2111.2521 Author : John Billekens Reference : https://developer-docs.citrix.com/projects/citrix-adc-nitro-api-reference/en/latest/configuration/basic/service_lbmonitor_binding/ Requires : PowerShell v5.1 and up ADC 13.x and up. ADC 12 and lower may work, not guaranteed.