Invoke ADCAddLbwlm - j81blog/J81.ADCToolkit GitHub Wiki

Invoke-ADCAddLbwlm

SYNOPSIS

Add Load Balancing configuration Object.

SYNTAX

Invoke-ADCAddLbwlm [-Wlmname] <String> [[-Ipaddress] <String>] [[-Port] <Int32>] [-Lbuid] <String>
 [[-Katimeout] <Double>] [-PassThru] [-WhatIf] [-Confirm] [<CommonParameters>]

DESCRIPTION

Configuration for web log manager resource.

EXAMPLES

EXAMPLE 1

Invoke-ADCAddLbwlm -wlmname <string> -lbuid <string>

An example how to add lbwlm configuration Object(s).

PARAMETERS

-Wlmname

The name of the Work Load Manager.

Type: String
Parameter Sets: (All)
Aliases:

Required: True
Position: 2
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Ipaddress

The IP address of the WLM.

Type: String
Parameter Sets: (All)
Aliases:

Required: False
Position: 3
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Port

The port of the WLM.

  • in CLI is represented as 65535 in NITRO API
Type: Int32
Parameter Sets: (All)
Aliases:

Required: False
Position: 4
Default value: 0
Accept pipeline input: False
Accept wildcard characters: False

-Lbuid

The LBUID for the Load Balancer to communicate to the Work Load Manager.

Type: String
Parameter Sets: (All)
Aliases:

Required: True
Position: 5
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Katimeout

The idle time period after which Citrix ADC would probe the WLM. The value ranges from 1 to 1440 minutes.

Type: Double
Parameter Sets: (All)
Aliases:

Required: False
Position: 6
Default value: 2
Accept pipeline input: False
Accept wildcard characters: False

-PassThru

Return details about the created lbwlm item.

Type: SwitchParameter
Parameter Sets: (All)
Aliases:

Required: False
Position: Named
Default value: False
Accept pipeline input: False
Accept wildcard characters: False

-WhatIf

Shows what would happen if the cmdlet runs. The cmdlet is not run.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

-Confirm

Prompts you for confirmation before running the cmdlet.

Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf

Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: False

CommonParameters

This cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.

INPUTS

OUTPUTS

NOTES

File Name : Invoke-ADCAddLbwlm Version : v2111.2521 Author : John Billekens Reference : https://developer-docs.citrix.com/projects/citrix-adc-nitro-api-reference/en/latest/configuration/lb/lbwlm/ Requires : PowerShell v5.1 and up ADC 13.x and up. ADC 12 and lower may work, not guaranteed.

RELATED LINKS

https://blog.j81.nl

⚠️ **GitHub.com Fallback** ⚠️