Invoke ADCAddLbmonitorservicegroupbinding - j81blog/J81.ADCToolkit GitHub Wiki
Add Load Balancing configuration Object.
Invoke-ADCAddLbmonitorservicegroupbinding [-Monitorname] <String> [[-Servicename] <String>]
[[-Dup_state] <String>] [[-Dup_weight] <Double>] [[-Servicegroupname] <String>] [[-State] <String>]
[[-Weight] <Double>] [-WhatIf] [-Confirm] [<CommonParameters>]
Binding object showing the servicegroup that can be bound to lbmonitor.
Invoke-ADCAddLbmonitorservicegroupbinding -monitorname <string>
An example how to add lbmonitor_servicegroup_binding configuration Object(s).
Name of the monitor.
Type: String
Parameter Sets: (All)
Aliases:
Required: True
Position: 2
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseName of the service or service group.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 3
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseState of the monitor. The state setting for a monitor of a given type affects all monitors of that type. For example, if an HTTP monitor is enabled, all HTTP monitors on the appliance are (or remain) enabled. If an HTTP monitor is disabled, all HTTP monitors on the appliance are disabled. Possible values = ENABLED, DISABLED
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 4
Default value: ENABLED
Accept pipeline input: False
Accept wildcard characters: FalseWeight to assign to the binding between the monitor and service.
Type: Double
Parameter Sets: (All)
Aliases:
Required: False
Position: 5
Default value: 1
Accept pipeline input: False
Accept wildcard characters: FalseName of the service group.
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 6
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseState of the monitor. The state setting for a monitor of a given type affects all monitors of that type. For example, if an HTTP monitor is enabled, all HTTP monitors on the appliance are (or remain) enabled. If an HTTP monitor is disabled, all HTTP monitors on the appliance are disabled. Possible values = ENABLED, DISABLED
Type: String
Parameter Sets: (All)
Aliases:
Required: False
Position: 7
Default value: ENABLED
Accept pipeline input: False
Accept wildcard characters: FalseWeight to assign to the binding between the monitor and service.
Type: Double
Parameter Sets: (All)
Aliases:
Required: False
Position: 8
Default value: 0
Accept pipeline input: False
Accept wildcard characters: FalseShows what would happen if the cmdlet runs. The cmdlet is not run.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: wi
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalsePrompts you for confirmation before running the cmdlet.
Type: SwitchParameter
Parameter Sets: (All)
Aliases: cf
Required: False
Position: Named
Default value: None
Accept pipeline input: False
Accept wildcard characters: FalseThis cmdlet supports the common parameters: -Debug, -ErrorAction, -ErrorVariable, -InformationAction, -InformationVariable, -OutVariable, -OutBuffer, -PipelineVariable, -Verbose, -WarningAction, and -WarningVariable. For more information, see about_CommonParameters.
File Name : Invoke-ADCAddLbmonitorservicegroupbinding Version : v2111.2521 Author : John Billekens Reference : https://developer-docs.citrix.com/projects/citrix-adc-nitro-api-reference/en/latest/configuration/lb/lbmonitor_servicegroup_binding/ Requires : PowerShell v5.1 and up ADC 13.x and up. ADC 12 and lower may work, not guaranteed.