VMs runs virtual machines with KubeVirt - built into Harvester, and something you can add to k3s or RKE2. The page appears when the cluster has KubeVirt.
It has two tabs: Machines, the VMs here, and Import, which brings VMs across from an Unraid server, settings and disks, and disk images from a web address.

A VM shows what it is really doing - Running, Stopped, Starting, Paused, or an error with its reason - and offers what fits: Start; Shut down, Restart, Pause or Console for a running one; Force off for one that will not shut down. Shut down asks the guest to power off, as its own power button would; Force off cuts the power at once, like pulling the plug, so unsaved work in it is lost. It opens to its disks, network cards and addresses, the guest OS (when the guest agent runs), and recent events.
A VM whose disk is still downloading shows how far it has got; one whose download has not started after three minutes says why.
A VM shows its operating system's logo - from what its guest agent reports, or the image it was made from - unless one is chosen for it under Logo in its menu, where Homestead's operating-system logos come first, then the app store's.
Monitoring in a VM's menu chooses how Homestead checks that it answers. A VM publishes no port, so Automatic tries the usual ones - SSH, RDP, HTTPS, HTTP, Proxmox and Home Assistant - and keeps asking the first that answers; a VM none of them answer on is not monitored, rather than called down. Or choose A port (a connection is enough) or A web page on a port. A VM monitored on a port you chose can also be rebooted when it is down - When it is down, as for containers; under Automatic it cannot, as Homestead cannot tell a VM that is down from one that does not answer on the usual ports.
Schedule shuts it down cleanly at one time and starts it at another, on the days you choose, as for containers; a start goes through the same capacity review as Start. None of these restart the VM.
Console has two views:
-
Screen - the VM's display (VNC) in the page, scaled to fit, with
Ctrl+Alt+Del and full screen. On a phone or tablet, Keyboard opens the
device's on-screen keyboard and types into the VM; it stays open while you tap
the screen to click. Paste (or Ctrl+Shift+V on the screen)
types the clipboard into the VM key by key - a VM's display has no clipboard
of its own - with Enter for each new line. Over HTTPS it types straight
away; on a plain
http://address the browser does not let the page read the clipboard, so a box opens to paste into first, with Press Enter after for a command. Plain Ctrl+V and Ctrl+C still go to the VM. When the VM shares what it copies (a guest with a clipboard agent), Copy from VM (Ctrl+Shift+C) puts it on yours. - Serial - the first serial port, as a terminal, for VMs that boot without a display (most cloud images). Its output is plain text: select it and press Ctrl+C, or Copy (Ctrl+Shift+C) for the selection or everything. Paste (Ctrl+Shift+V) sends the clipboard to the port as typed, a line at a time. Ctrl+C with nothing selected interrupts, as in a terminal.

๏ผ New VM asks for a name, CPU cores, memory, a disk size, a root password and a boot disk:
- Boot disk - an image from the image store, a Harvester image, an image downloaded from a URL, a disk you imported, or blank, to install from an ISO added later as a CD-ROM.
- Root password - set through cloud-init, so a cloud image has a login from its first boot. Optional for an imported disk that already has one.
- Storage class - on Harvester, a disk from an image lives on that image's own class, and every disk can live-migrate between hosts. On other clusters the disk goes on the class you pick; on local-path the VM stays on the host its disk is on.
Guest type sets the firmware, TPM, clock and devices as Proxmox's OS type
does, and the network card: VirtIO for Linux, an Intel e1000e for Windows.
Windows has no VirtIO network driver of its own, so a Windows guest on VirtIO
comes up with no network until the guest tools from virtio-win.iso are
installed; Windows drives an e1000e out of the box (Proxmox gives its Windows
types an Intel e1000 for the same reason). For a Windows VM made before this,
Edit โ Network changes its card to e1000e, or install the guest tools from
its drivers CD and keep VirtIO.
The VM starts on the pod network; Edit โ Network puts it on a bridged network (Harvester's VM networks, or any Multus network), where it gets an address from your router. Edit โ Cloud-init takes SSH keys, users and packages.
Select Isolated VM on the Network page when creating or editing a VM to remove all virtual network cards and disable KubeVirt's automatic pod-network card. Network, address and Service VIP controls are disabled while selected. The setting is saved with the VM and checked by the create/edit API; clear it before adding a network card again. Disks and PCI/USB passthrough are retained. A physical network device passed through PCI or USB can still connect the guest.
Removing the last interface also disables automatic attachment, so an empty network list stays empty at the next boot. Older VMs with an empty saved list and automatic attachment enabled display Network ยท automatic and a warning. Saving an empty network list or selecting Isolated VM disables that default. For a running VM, save first and separately review a restart to apply removal; saving alone does not disconnect its current guest.
On the pod network a VM is reached through a Service, like a container. On a VM network bridged to the LAN it is a machine there like any other: choose Address โ One of its own and pick one of the free addresses IP addresses knows of in that subnet - outside the DHCP range and the VIP pools. It is written into cloud-init's network config (matched to the VM's MAC, so it lands on the right interface whatever the guest calls it), checked against everything already on the network, and recorded in IP addresses under the VM's name. Cloud-init - the password included - is kept in a Secret, not in the VM's own definition.
No VM network yet? Networking โ ๏ผ LAN network makes one. On Harvester: untagged, on the same LAN as the hosts, or on a VLAN your switch carries to them - the same network Harvester's dashboard makes under Networks โ VM Networks, so it shows there too. On k3s or RKE2: on a host bridge, or on the hosts' NIC For: Virtual machines, through macvtap - see LAN networks and A host bridge. Any form that needs one offers to make it, and comes back once it is made.
Image store on the VMs page lists cloud images from their publishers, for your nodes' architecture (amd64 or arm64), grouped by distribution. Each variant shows its download size, and a tooltip says what it is for:
| Distribution | Variants |
|---|---|
| Ubuntu 24.04 and 22.04 LTS | Server, and Minimal: smaller, fewer packages, no manuals |
| Debian 13 and 12 | Cloud: a kernel slimmed for VMs; Generic: every driver, for passed-through hardware |
| Fedora Cloud | the newest release |
| Rocky Linux 10 and 9 | Base, and LVM: the disk under LVM |
| AlmaLinux 10 and 9, CentOS Stream 10 and 9 | the standard cloud image |
| openSUSE Leap 16.0, 15.6 and Tumbleweed | minimal cloud VM |
| Arch Linux | cloud image |
| Alpine Linux | cloud-init image: tiny, musl and OpenRC |
Each comes from the publisher's own "latest" address, has cloud-init, and
grows to fill its disk. The table shows which user to sign in as (ubuntu,
debian, alpine...), with the password set on New VM. Filter narrows
the list, for example to "minimal". New VM on a row opens the form with
that image chosen.
Your images on this cluster lists the VM images already here that did not come from the catalogue: uploads, other downloads, anything made in Harvester's dashboard. Each has New VM. An image downloaded from a catalogue address, even outside the store, shows on that catalogue row as here.
On Harvester, Keep makes an image a local Harvester image. It uses one already downloaded from the same address, or downloads it. Every VM then copies the local image instead of downloading it again. A kept image with current ticked checks for a newer build twice a day, by asking the publisher (nothing is downloaded until there is one). A new build downloads beside the old; once it is ready, new VMs use it, and older builds that no disk was made from are deleted. Check for newer builds asks now.
On k3s and RKE2, CDI fills each VM's disk straight from the publisher, so a new VM always starts from the newest build and there is nothing to keep.
Your own disk image (qcow2, vmdk, raw, vdi, vhd or vhdx) is imported from a web address.
Each VM shows its address in full - with a button to copy it, how many more it has, and the network it is on - then its size and host on one line. A running VM also shows what it is using: CPU against its cores, memory against what it was given, and how fast it is reading from and writing to its disks. CPU and memory are its launcher pod's, from the metrics API; disk traffic is KubeVirt's own count, read from virt-handler on each node every half minute. What cannot be measured shows a dash that says why. The switch at the top shows the same as rows, one VM a line.
๏ผ k3s cluster makes a small k3s cluster from VMs here - for trying k3s,
an app, or Homestead itself on a cluster of its own. Choose how many servers
(one, or three to survive one failing) and workers, their size, the image
(Ubuntu 24.04 by default), the VM network and one address each. Review
says what goes where and names anything already at an address; Create
cluster makes the VMs with a join token made for them, and the job tray
follows the cluster coming up - VMs running, k3s answering, then its own
Homestead at http://<first address>:8088. It can run k3s with Longhorn and
Homestead (what a new install gets), k3s and Homestead on local-path storage,
or k3s alone. The nodes' login is ubuntu with the password you chose.
Include KubeVirt installs KubeVirt and CDI on the new cluster too, so its Homestead can run VMs of its own. The nodes then get this host's CPU as it is, so VMs inside run with hardware virtualisation where this host allows nested virtualisation; where it does not, they are emulated. Give the nodes more memory for it.
Log on the job shows each step it has taken, and each node's console as it installs - cloud-init, then k3s and what comes with it. The nodes ask KubeVirt to keep their console output, which it does from 1.1 even where Harvester turns that off for other VMs; with an older KubeVirt, the log says so and where to look instead.
Interrupted or failed creation keeps partial VMs, disks and Secrets. Open the job's Inspect outcome action to compare recorded creation receipts with the current resources. An administrator can resolve tracking after inspecting the resources and typing the batch name. This does not delete resources, resend a request, cancel an upstream operation or prove that the guest cluster is ready. Remove unwanted resources deliberately after checking their ownership and data.
Create, start, restart, resume and start-capable edits show a capacity review. High or unknown RAM usage can be acknowledged. Missing hardware, storage conflicts, changed resource identities and insufficient scheduler capacity cannot be bypassed. The server rechecks before writing; the review is not a scheduler reservation.
Launch host identifies a required host, a preferred host, or the eligible hosts Kubernetes can choose from at launch. A preference allows another eligible host. Resuming a paused VM keeps its current host; restarting can reschedule it.
For NUMA VMs, enable Settings โ Hardware and storage โ Add-ons โ Node probe โ VM placement checks. The short dialog explains host access and the monitoring restart; socket settings are under Advanced. It uses an additional 32โ96 MiB per probe node. Check hosts explains missing or unsupported evidence. Workloads are not restarted, and disabling checks does not delete their volumes.
Locality checks need Static CPU and memory managers. Multi-NUMA hosts also need
pod-scoped single-numa-node topology policy. Homestead verifies current policy,
exclusive CPU allocations and local memory/hugepages together; it does not configure
kubelet policy for you. Dynamic claims and unverified device-local NUMA placement
remain unsupported and blocked. Kubernetes still makes the final placement.
Power requests and saves are journalled in Recent jobs. If a response is lost, inspect the outcome before trying again; Homestead does not automatically replay an uncertain mutation. During an HA upgrade, finish upgrading all Homestead replicas before making VM changes. Test shared-storage locking and guest-agent compatibility on disposable resources before relying on them for production recovery.

Edit covers what a VM is made of:
- General - cores, memory, run strategy, description, a host to keep it on;
- Hardware - the virtual machine's hardware, in folded sections that each show what they are set to (see Hardware);
- Disks - boot order, bus, growing a disk, detaching one (its volume is kept), adding a disk or CD-ROM - from the ISO library, a Harvester image or a URL - and a new source for a disk that failed to download;
- Network - model, network, MAC, adding and removing cards;
- Cloud-init - user and network data.
Changes apply at the next boot, or at once with Restart now so the changes take effect. Edit YAML opens the VM in the Resources editor for anything else.
The Hardware tab keeps each group folded, with its settings on one line:
- Processor - sockets, cores per socket and threads; the CPU model (host-model, host-passthrough, or a named model every node offers, which keeps the VM movable across mixed hardware); dedicated CPUs, pinned one to one as Proxmox's affinity does; and an isolated emulator thread.
- Firmware and security - BIOS or UEFI, Secure Boot, kept EFI variables, a virtual TPM 2.0 (on, or with its state kept), and the machine type.
- Guest tuning - Hyper-V enlightenments for Windows, hiding KVM from GPU drivers that refuse to run in a VM, and the clock's time zone (UTC, or local time for Windows).
- Devices - primary boot output (web console, physical GPU or serial), the serial console, a tablet pointer, a random-number device, the memory balloon, a sound card.
- Memory and placement - hugepages, and what happens when its node is drained: live-migrate, try to, or stop.
Guest type applies a preset, as Proxmox's OS type does: Windows 11 / Server 2022+ (UEFI with Secure Boot, a kept TPM, Hyper-V enlightenments, a tablet pointer, local time), Windows 10 / Server 2019, Linux server, Linux desktop, Linux cloud image (BIOS) and Headless appliance. A preset only fills in the fields; nothing changes until the edit is reviewed and saved, and only the fields that changed are written. The same presets are the Guest type of a new VM.
What a setting needs from the cluster is said as it is chosen: dedicated CPUs need the kubelet's static CPU manager policy, hugepages must be reserved on the node, host-passthrough limits live migration to identical CPUs, and kept EFI or TPM state needs KubeVirt's VMPersistentState feature before KubeVirt 1.5. Settings KubeVirt would refuse - Secure Boot on BIOS, say - are refused before anything is saved.
For a step-by-step GPU setup, including vBIOS capture and physical display output, see GPU passthrough.
A VM can have a host's own PCI device - a GPU, a NIC, an HBA - or a USB device. Two steps: the host hands the device over, then the VM asks for it.
On the host - Nodes โ select a host โ Hardware โ Devices for VMs โ Look at its devices:
-
IOMMU has to be on. On k3s and RKE2, Switch IOMMU on adds
intel_iommu=on iommu=pt(iommu=pton AMD, whose IOMMU is on by default) to the kernel command line - a copy of/etc/default/grubis kept - and it is on from the host's next restart, from Host actions. The firmware needs VT-d or AMD-Vi enabled too. -
Give to VMs hands a PCI device to
vfio-pciat once and at every boot, with every device in its IOMMU group (a GPU's audio function, say; PCI bridges stay), and lists it with KubeVirt ashomestead.io/pci-<vendor>-<device>. A device carrying the host's network, or with a disk the host has mounted, is refused. Give back returns it to its own driver. Giving away the host's boot GPU makes its local display go dark; keep remote access to Homestead and the host available. -
Offer to VMs on a USB device lists it with KubeVirt by vendor and product
(
homestead.io/usb-<vendor>-<product>), on any host that has one; nothing on the host changes. - On Harvester, the same buttons make and remove Harvester's own PCIDeviceClaims and USBDeviceClaims, as its Devices page does. Its pcidevices-controller add-on must be enabled.
On the VM - New VM โ Passthrough or Edit โ Passthrough: Add device from what the hosts offer, each shown with the hosts that have it. A VM with a host device runs only on such a host and cannot live-migrate; the change applies at its next start. The edit form also lets you select a different resource for an existing device. Host preparation opens in a separate tab so the VM configuration stays in place.
The Passthrough picker shows inspected device models, vendor/product IDs, hosts, PCI addresses and IOMMU groups, plus VMs currently using the resource. On k3s/RKE2, devices offered before Homestead retained inventories may initially show only their IDs: inspect or refresh that host under Hardware โ Devices for VMs once to populate their names. Harvester device names come directly from its inventory. Names and addresses describe the hardware; the selection still requests a KubeVirt resource, which can represent matching devices on several hosts. Current host availability comes from the cluster, independently of the retained names.
A GPU's audio function moves to vfio-pci with its IOMMU group on k3s/RKE2. Add that function separately in Passthrough if the guest needs it too.
Stopped VMs can be configured with the same PCI or USB resource. Saving those configurations does not reserve the hardware. Start checks active VMs and pending starts against the number of devices available on eligible hosts. If the only matching device is busy, the review names its holder: stop that VM and wait for its device allocation to be released before starting the other. Several matching physical devices can serve several VMs when capacity allows.
Editing a running VM reuses its verified existing GPU and USB allocations; keeping its own device does not count as requesting a second copy. Additional devices still need free capacity. If the review says Live edit requires a stable, verified resident launcher, wait for startup, shutdown or migration to finish, refresh, and review again. Stop the VM before changing its pinned host. Saving does not guarantee that a hardware change can be applied live.
To capture a card's ROM, open its node's Hardware โ Devices for VMs,
inspect the devices, and choose Capture vBIOS beside the GPU. Give the
GPU to VMs and stop any VM using its IOMMU group first. Homestead reads the
card's sysfs ROM, checks its PCI image headers and vendor/device IDs, and
downloads a .rom file. It does not detach a host driver or reset the card.
For an idle VFIO GPU that has runtime-suspended, capture temporarily wakes the
card and restores its previous power policy afterwards, including on failure.
The ROM read switch is disabled again when the helper finishes. A card that
does not expose a readable ROM needs a dump from that exact card, such as
one captured with GPU-Z; capture does not flash or modify the GPU firmware.
Some GPUs need their ROM given to the VM - a card the host booted from, which
hides its ROM afterwards, or one that needs a patched ROM. On the device's row,
choose the ROM file when adding the device or editing it: up to 640 KiB, starting with the PCI ROM signature 55 AA
(a dump from GPU-Z or nvflash may carry a header to trim first). KubeVirt has
no field for this, so Homestead uses its hook sidecar: a small script in a
ConfigMap of the VM's (<vm>-vbios), with the ROM inside, runs as KubeVirt
defines the VM, writes the ROM where the VM's QEMU can read it, and names it as
that device's ROM - changing nothing if anything goes wrong. It switches on
KubeVirt's Sidecar feature. clear removes it; removing the device removes
its ROM.
Clearing a ROM removes its contents and the VM's hook reference; the empty managed ConfigMap is retained for inspection and reuse. Several ROM files must fit together within the ConfigMap's 1 MiB limit. If a saved ROM is missing, replace or clear it explicitly in the edit form; unrelated edits keep it intact.
In New VM โ Hardware โ Devices, or VM โ Edit โ Hardware โ Devices, Primary boot output chooses Web console (virtual display), Passed-through GPU (physical monitor), or Serial console only. The change applies at the VM's next start.
GPU output requires an attached passthrough GPU. It turns off virtual VGA and uses UEFI; when changing from BIOS, Secure Boot starts off. Connect the monitor to the GPU's physical port and provide a UEFI-capable vBIOS if the card needs one. The guest needs its GPU drivers for OS output. A guest installed for BIOS may need its bootloader repaired before it can boot using UEFI. The VNC screen is unavailable with GPU or serial output; keep the serial console enabled for troubleshooting. Switching back to the web console leaves UEFI in place. With several passed-through GPUs, the guest firmware chooses which card to initialize; this setting chooses physical GPU output rather than a specific card or connector.
If removing the last GPU, change Primary boot output to web console or serial in the same edit. Clearing a vBIOS file alone does not restore the virtual display. A serial console also needs the guest to send output to its serial port; enabling the virtual port alone does not configure the guest OS.
- On the host, check IOMMU and Give to VMs for the GPU. If IOMMU was just enabled, restart the host and inspect it again before continuing.
- Stop VMs using the card or its IOMMU group. If the card needs a ROM, choose Capture vBIOS on its host and keep the downloaded file.
- In the VM's Passthrough tab, add the GPU and select that ROM beside the device. A card that works with its default ROM needs no uploaded file.
- In Hardware โ Devices, select Passed-through GPU (physical monitor) and keep the serial console enabled. Review the change and save it. Check that a guest previously installed for BIOS can boot with UEFI.
- Connect the monitor to the passed-through GPU and select the matching input. Start the stopped VM, or restart it if it was already running when you changed the settings. Install the guest's GPU driver for OS display output.
The physical display is separate from Homestead's VNC screen. See GPU troubleshooting if the VM runs but the monitor stays blank.
Copy to cluster and Move to cluster show a passthrough mapping for each source device. Choose a resource offered by the destination's hosts, or Leave out. Selected devices must be available on a common host. Prepare IOMMU and devices on that host before starting the transfer.
For each retained device, keep the source vBIOS, use the destination device's default ROM, or upload a replacement. A different GPU may require a different ROM. Homestead copies managed ROM data and rebuilds its hook ConfigMap on the destination. It removes the source hostname selector; other placement rules remain. Custom hook sidecars require separate dependency setup and are refused by this transfer flow. The source's device settings are unchanged.
ISO library (on the VMs page) lists the .iso files in folders you pick
on your Network shares - copy installers there from your PC
over SMB. ๏ผ Folder chooses a share, then a folder on it; nothing else is
set up. A CD-ROM cannot read one file on a shared volume, so each ISO is made
ready once: Make ready copies it into a volume of its own, on a storage
class every node can mount where there is one, so one copy serves every VM on
any node. Its progress shows in the library; a file replaced by a new one of
another size is copied again under a new name.
On Longhorn the copies go on a class Homestead makes for them,
homestead-isos: one replica, since the original stays on the share, and
no data locality. VMs on any node still read the one copy - it is served over
the network, so nothing is tied to the node holding the replica. If that node
is down, a VM with the ISO still in a drive waits until it is back, or until
the ISO is ejected or made ready again; a VM whose install is done and ISO
ejected is not affected.
Copies are kept only while wanted: one no VM has in a drive is removed after the days set at the foot of the library (7 by default, 0 keeps them), and the library says how long each has left. It comes back with Make ready.
A ready ISO is offered as a CD-ROM's contents in Edit โ Disks โ ๏ผ CD-ROM, attached read-only, and Detach ejects it. A new VM can Install from an ISO: it gets a blank disk and the ISO in a CD-ROM drive that boots first, with no root password - the installer asks for its own. An ISO's volume a VM still has in a drive cannot be deleted; deleting one keeps the file on the share.
Delete asks for the VM's name and whether to take its disks too. Disks you keep are released from the VM first, so they are not deleted with it. A VM deleted while its image is still downloading stops the download.
VMs need KubeVirt, and CDI to fill their disks from images. Three ways to get both:
-
A new k3s cluster: add
--kubevirtto the k3s script'sserverline - see Installing on k3s. - A cluster already running: Settings โ Hardware and storage โ Add-ons โ Install KubeVirt, or Install KubeVirt on the VMs page. Homestead installs the newest KubeVirt and CDI releases through the Helm controller k3s and RKE2 run, and the VMs page appears once they are up.
- By hand, following KubeVirt's and CDI's instructions.
Hosts need hardware virtualisation (ls /dev/kvm shows it) for VMs to run at
full speed. The node probe reports it on each node, and Add-ons says which
have it. With none, KubeVirt is set to emulate: VMs work, many times slower.
Without CDI, VMs start from a blank disk and downloading images asks for CDI
first.