Note it is simply not possible to keep this table complete and up-to-date. Devices similar to the ones listed below likely work as well. If in doubt, before purchasing a specific product please see the DiscussionForums. Generally, you can use the SwitchLinc definition and class to enable basic on/off functionality for a new device.
| Name | Model # | Support | Definition | Documentation | 
|---|---|---|---|---|
| PLM - PowerLinc Modem | 
2412S 2412U 2412UH 2413S (Dual-Band) 2413U (Dual-Band)  | 
Yes | INSTEON_PLM | InsteonPLM | 
| Insteon Hub | 2242-222 | Yes | INSTEON_PLM | InsteonPLM | 
| Portable USB Adapter | 2448A7 | Yes | INSTEON_PLM | InsteonPLM InsteonRFOnly | 
| PLC - PowerLinc Controller | 
2414S 2414U  | 
No | Will never be supported. | |
| ControlLinc | 2430 | No | 
Old device. Likely will never see support (see this post)  | 
|
| RemoteLinc | 2440 | Yes | INSTEON_REMOTELINC | RemoteLinc Class InsteonRFOnly | 
| IOLinc | 2450 | Yes | INSTEON_IOLINC | IO_Linc Class | 
| EZIO | EZIOxXx | Limited | Maybe with INSTEON_IOLINC | See IO_Linc Class | 
| LampLinc | 
2456D3 2456D2 2856D2  | 
Yes | INSTEON_LAMPLINC | LampLinc Class | 
| 
BulbLinc aka Insteon LED Bulb aka Insteon LED Bulb for Recessed Lights, Floodlights  | 
2672-222 (9W) 2674-222 (12W)  | 
Yes | INSTEON_BULBLINC | BulbLinc Class | 
| ApplianceLinc | 2456S3 | Yes | INSTEON_APPLIANCELINC | ApplianceLinc Class | 
| 
SwitchLinc ToggleLinc  | 
2476DH 2477DH (Dual-Band) 2876D 2466D  | 
Yes | INSTEON_SWITCHLINC | SwitchLinc Class | 
| 
SwitchLinc Relay ToggleLinc Relay  | 
2476D 2477D (Dual-Band) 2466S  | 
Yes | INSTEON_SWITCHLINCRELAY | SwitchLincRelay Class | 
| In-LineLinc | 2475D | Yes | Use INSTEON_SWITCHLINC | SwitchLinc Class | 
| OutletLinc | 
2472D (Dual-Band) 2473D  | 
Yes | Use INSTEON_SWITCHLINC | SwitchLinc Class | 
| OutletLinc Relay | 2473S | Yes | Use INSTEON_SWITCHLINCRELAY | SwitchLincRelay Class | 
| SocketLinc | 2454D | Yes | Use INSTEON_SWITCHLINC | SwitchLinc Class | 
| KeypadLinc | 
2486D 2334 (Dual-Band)  | 
Yes | INSTEON_KEYPADLINC | KeyPadLinc Class | 
| KeypadLinc Relay | 
2486S 2487S (Dual-Band)  | 
Yes | INSTEON_KEYPADLINCRELAY | KeyPadLincRelay Class | 
| 
Motion Sensor aka MotionLinc  | 
2842-222 2420M (deprecated)  | 
Yes | INSTEON_MOTIONSENSOR | MotionSensor Class InsteonRFOnly | 
| Thermostat | 2441TH | Yes | INSTEON_THERMOSTAT | 
Insteon_Thermostat Class  Note: Not a 'deaf' Device InsteonRFOnly  | 
| 
EZFlora aka EZRain  | 
EZFloraIV1 | Yes | INSTEON_IRRIGATION | Insteon_Irrigation Class | 
| TriggerLinc | 
2843-222 2421 (deprecated)  | 
Yes | INSTEON_TRIGGERLINC | Insteon_TriggerLinc Class InsteonRFOnly | 
| FanLinc | 2475F | Yes | INSTEON_FANLINC | Insteon_FanLinc Class | 
| MicroSwitch | 
2442-222 (Dimmer) 2443-222 (On/Off) 2444-222 (Open/Close)  | 
Yes | INSTEON_MICROSWITCH | MicroLinc Class | 
| SynchroLinc | 2423A5 | Yes | INSTEON_SYNCHROLINC | Insteon_SynchroLinc Class | 
| iMeter | 2423A1 | Yes | INSTEON_IMETER | Insteon_iMeter Class | 