The +/- 12v square wave is created by supplying an operational amplifier with a +/- 12v power supply created by the DC/DC converter module from the 12 volt supply. The output of the op-amp is buffered by R1 (on Google Code) (which allows the EV to drag the voltage down without unduly straining the output stage of the amp) and fed to the vehicle. The pilot pin is also fed back to ADC1 of the CPU, which allows the CPU to sense the voltage. The CPU will detect the negative portion of the signal not being all the way at -12v as a missing diode condition and will use the voltage (and therefore, the resistance being offered by the EV on the pilot) to select states A through D (waiting for vehicle, vehicle connected, vehicle requests charging, vehicle requests vent+charge). In stage A, the CPU will select a solid +12v output, and in the other states (including the error state E), it will output a square wave whose duty cycle represents the current availability setting made in the UI for the current charging mode (L1 or L2). It does this by oscillating PB2 under software control.
The current transformer coil detects any unbalanced current flowing through conductors passing through it. By passing both of the J1772 power cables through it, any current leaked to ground in the EV will result in a differential current within the CT. This will result in a voltage appearing at the input of the OP amp (diode D1 protects against excessive voltage in a run-away leakage event, such as a conductor short to ground). The second OP amp acts as a comparator and will "switch" from a low output to a high output when a threshold is exceeded. This output is fed as a fault indication into the CPU, which will register a ground fault and open the relay.
The two AC line monitor chips act as opto-isloators. The presence of an AC voltage potential relative to ground on either L1 or L2 will result in pulses appearing on PD3 and PD4 of the CPU. Since the test pins are downstream of the relay, there should be no pulses when the relay is open. This is how the stuck-relay test is accomplished. Automatic selection between L1 and L2 is accomplished by observing the pulses while the relay is closed. L1 will have pulses on only one line, L2 will have pulses on both. A lack of pulses on either while the relay is closed is a ground test failure.
The transistor and resistor on PB0 and PD7 are straightforward open-collector switching circuits. The reverse bias diodes across the relay coil protect the transistors from coil collapse voltages when the transistors are turned off.