relays.xml - emelianov/ehcontrol3 GitHub Wiki
Parameter | Description | Default |
---|---|---|
relay | Relay Sub-section (4 entries: Burner, Zone1, Zone2, Floor Zone) | |
relay\pin | GPIO pin (ESP or GPIP Extension) | 1 |
relay\name | Name (Used nowhere) | "" |
relay\gid | ID | 0 (Not set) |
relay\inverse | Use inverse (1) on direct (0) logic | 0 |
relay\t0 | Normal mode temperature | Burner: Default Normal mode temperature | 20 |
relay\t1 | Alternative mode temperature | Burner: Default Eco mode temperature | 20 |
relay\t2 | Eco mode temperature | Burner: Idle temperature | 20 |
realy\t3 | Reserved | Burner: Alarm temperature | 20 |
relay\ton | Alternative mode start time (minutes from midnight) | 0 |
relay\toff | Alternative mode end time (minutes from midnight) | 360 |
t | Temperature curve Sub-section (8 entries maximum) | |
t\e | Outside temperature | 0 |
t\h | Burner temperature to use | 60 |
<relays>
<relay>
<pin>1</pin><name>RX</name><gid>0</gid>
<inverse>0</inverse>
<t0>20</t0><t1>0</t1><t2>40</t2><t3>80</t3>
<ton>0</ton><toff>360</toff>
</relay>
<relay>
<pin>3</pin><name>D5</name><gid>0</gid>
<inverse>0</inverse>
<t0>15</t0><t1>15</t1><t2>15</t2><t3>23</t3>
<ton>0</ton><toff>360</toff>
</relay>
<relay>
<pin>13</pin><name>D7</name><gid>0</gid>
<inverse>0</inverse>
<t0>15</t0><t1>15</t1><t2>15</t2><t3>23</t3>
<ton>0</ton><toff>360</toff>
</relay>
<relay>
<pin>14</pin><name>TX</name><gid>0</gid>
<inverse>0</inverse>
<t0>20</t0><t1>20</t1><t2>20</t2><t3>20</t3>
<ton>1260</ton><toff>360</toff>
</relay>
<t><e>15</e><h>0</h></t>
<t><e>10</e><h>40</h></t>
<t><e>5</e><h>42</h></t>
<t><e>0</e><h>45</h></t>
<t><e>-5</e><h>50</h></t>
<t><e>-10</e><h>65</h></t>
<t><e>-15</e><h>75</h></t>
<t><e>-20</e><h>80</h></t>
</relays>