Physical specifications 1)
| Property | Value |
|---|---|
| Dimensions 2) | Width=235mm, height=212mm, depth=125mm |
| Material | ABS, glass fiber reinforced 3) |
| Storage temperature | 5°C to 70°C |
| Operating temperature | 5°C to 50°C |
| Air humidity 4) | 10% to 90% relative air humidity |
| Max. measurable flow | 2 L/min to 40 L/min |
| Max. water pressure | 6 bar (Todo easymetal) |
- : Please note that the limiting factors are not defined by Korrostop4.0 but by your EDM machine and the E.KO IONISER or its operating!
- : without connections
- : various state-of-the-art materials were used for connections
- : Storage and operation
Electrical connection
| Area | Property | Value |
|---|---|---|
| Plug-in power supply unit | Input voltage | 100V to 240V AC voltage |
| Plug-in power supply unit | Maximum power consumption | 300mA |
| Plug-in power supply unit | Frequency | 50/60 Hz |
| PLC connection | Channels | 2 (potential-free), electrically isolated, max. 70V/20mA |
| PLC connection | Switching element | Optocoupler ILD213T 1) |
| PLC connection | Maximale load | per channel to 70V/20mA |
- : Please also refer to the datasheet) for the Optocoupler ILD213T
Measuring accuracy / measuring range
| Sensor | Unit | Min | Max | Deviation |
|---|---|---|---|---|
| Water conductance input | µSiemens/cm | 0,1 | 50,0 | <+-5% |
| Water conductance output | µSiemens/cm | 0,1 | 5,0 | <+-2,5% |
| Water temperature | °C | 5 | 60 | <+-0,1 1) |
| Flow rate | Liter/min | 0 | 25 | < +-10% |
| Water quality of the E.KO IONISER | % | 0 | 100 | -- |
- : Offset errors < 2°C