Physical specifications 1)

Property Value
Dimensions 2) Width=235mm, height=212mm, depth=125mm
Material ABS, glass fiber reinforced 3)
Storage temperature 5°C to 70°C
Operating temperature 5°C to 50°C
Air humidity 4) 10% to 90% relative air humidity
Max. measurable flow 2 L/min to 40 L/min
Max. water pressure 6 bar (Todo easymetal)
  1. : Please note that the limiting factors are not defined by Korrostop4.0 but by your EDM machine and the E.KO IONISER or its operating!
  2. : without connections
  3. : various state-of-the-art materials were used for connections
  4. : Storage and operation

Electrical connection

Area Property Value
Plug-in power supply unit Input voltage 100V to 240V AC voltage
Plug-in power supply unit Maximum power consumption 300mA
Plug-in power supply unit Frequency 50/60 Hz
PLC connection Channels 2 (potential-free), electrically isolated, max. 70V/20mA
PLC connection Switching element Optocoupler ILD213T 1)
PLC connection Maximale load per channel to 70V/20mA
  1. : Please also refer to the datasheet) for the Optocoupler ILD213T

Measuring accuracy / measuring range

Sensor Unit Min Max Deviation
Water conductance input µSiemens/cm 0,1 50,0 <+-5%
Water conductance output µSiemens/cm 0,1 5,0 <+-2,5%
Water temperature °C 5 60 <+-0,1 1)
Flow rate Liter/min 0 25 < +-10%
Water quality of the E.KO IONISER % 0 100 --
  1. : Offset errors < 2°C