Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Hive Active Heating Receiver SLR2 #2978

Closed
1 of 7 tasks
peterguy04 opened this issue Jun 22, 2020 · 5 comments
Closed
1 of 7 tasks

Hive Active Heating Receiver SLR2 #2978

peterguy04 opened this issue Jun 22, 2020 · 5 comments

Comments

@peterguy04
Copy link

Device

  • Product name: Hive Active Heating
  • Manufacturer: Computime
  • Model identifier: SLR2
  • Device type:
    • Light
    • Lock
    • Remote
    • Sensor
    • Siren
    • Thermostat
    • Other:

Screenshots

  • Endpoints and clusters of the node
    End point and clusters

  • Node Info panel
    Node INFO

  • Basic Cluster attributes in the Cluster Info panel.
    05basic cluster

05

05OTAU
05thermostat 1
05thermostat2

06

06thermostat 1
06thermostat 2

07

07 temp measurement

08

08 temp measurement

@Smanar
Copy link
Collaborator

Smanar commented Jun 22, 2020

Lol, but you have the complete collection ?

@peterguy04
Copy link
Author

@Smanar haha yes i have a few Hive devices.

@Smanar
Copy link
Collaborator

Smanar commented Jun 22, 2020

I will take it, like that I will make a package

@Smanar
Copy link
Collaborator

Smanar commented Jun 24, 2020

We are searchaing how to act on the second relay.
If someone have information ?

@Smanar
Copy link
Collaborator

Smanar commented Jul 12, 2020

@peterguy04 have sniffed the original gateway, for info


Endpoint 6
cluster 0201

for "on - manual"

attribute 0x001C > 0x04 = "heat"
attribute 0x0023 > 0x01 = "Setpoint Hold On"

For "off"

attribute 0x001C > 0x00 = "off"
attribute 0x0023 > 0x00 = "Setpoint Hold Off"

For "boost"

attribute 0x001C > 0x05 = "Emergency heating"
attribute 0x0023 > 0x01 = "Setpoint Hold On"
attribute 0x0024 > 0x3C = 60


Endpoint 5
cluster 0201

for "on - manual"

attribute 0x001C > 0x04 = "heat"
attribute 0x0023 > 0x01 = "Setpoint Hold On"
attribute 0x0012 > 1150

For "off"

attribute 0x001C > 0x00 = "off"
attribute 0x0023 > 0x00 = "Setpoint Hold Off"
attribute 0x0012 > 0

For "boost"

attribute 0x001C > 0x05 = "Emergency heating"
attribute 0x0023 > 0x01 = "Setpoint Hold On"
attribute 0x0024 > 0x3C = 60
attribute 0x0012 > 2400