IOCM Operations - dcm4che/dcm4chee-arc-light GitHub Wiki
Tests
Reject Instances
Store objects to archive and trigger Export of objects either using Export Rule as explained in
Forwarding of received instances or go back to Studies page and manually trigger an Export by selecting Queued Exporter option and selecting Exporter as
CopyToNearlineStorage.
Verify that the objects are exported by going to Monitoring page Export tab; the status should be COMPLETED. One
can also verify the objects stored on nearline storage system.
Verify Storage IDs of Study private attribute on Study/Series/Object level as fs1,nearline and Other Storage Sequence
private attribute on Object level shall have the nearline storage ID.
-Reject the study and depending on your requirement you may or may not choose to export the Rejection Note as well to
nearline storage system. If exported, the same private attributes can also be checked to contain the value as nearline.
Copy Instances
Store objects to archive and trigger Export of objects either using Export Rule as explained in
Forwarding of received instances or go back to Studies page and manually trigger an Export by selecting Queued Exporter option and selecting Exporter as
CopyToNearlineStorage.
Verify that the objects are exported by going to Monitoring page Export tab; the status should be COMPLETED. One
can also verify the objects stored on nearline storage system.
Verify Storage IDs of Study private attribute on Study/Series/Object level as fs1,nearline and Other Storage Sequence
private attribute on Object level shall have the nearline storage ID.
Copy the study to a different study and verify on the target study Storage IDs of Study private attribute on
Study/Series/Object level as fs1,nearline and Other Storage Sequence private attribute on Object level as nearline storage ID.
Move Instances
Store objects to archive and trigger Export of objects either using Export Rule as explained in
Forwarding of received instances or go back to Studies page and manually trigger an Export by selecting Queued Exporter option and selecting Exporter as
CopyToNearlineStorage.
Verify that the objects are exported by going to Monitoring page Export tab; the status should be COMPLETED. One
can also verify the objects stored on nearline storage system.
Verify Storage IDs of Study private attribute on Study/Series/Object level as fs1,nearline and Other Storage Sequence
private attribute on Object level shall have the nearline storage ID.
Move the study to a different study and verify on the target study Storage IDs of Study private attribute on
Study/Series/Object level as fs1,nearline and Other Storage Sequence private attribute on Object level as nearline storage ID.
On the source study level one shall see KO if the reason for rejection while moving the study was Patient Safety or