Battery: Kia EV6 - dalathegreat/Battery-Emulator GitHub Wiki

[!CAUTION] Working with high voltage is dangerous. Always follow local laws and regulations regarding high voltage work. If you are unsure about the rules in your country, consult a licensed electrician for more information.

[!IMPORTANT]
The EGMP battery platform cannot communicate over CAN. It only supports CAN FD!

Pinout on battery image image

image image image

Batterie Data (from Kia/Hyundai Service Manual) image

Batterie BMU/CMU Info image image image image image

Images etc.

Similar wiki: E-GMP platform

***** Below find pin connection required ****** 1,2,12 - 12v / 3+14 - shunt / 7+8 - resistor / 10+11 - can-fd (to MCP board) / 13 - 5v / 24+25 - shunt / 27+28 - resistor / 29+30 - resistor / 31+32+33 - gnd /

You also need to shunt the 3 interconnect in the 3 HV connectors. You can measure if the shunt is connected correctly with a voltmeter. If closed correctly the shunt should measure 2.5V