How do I install DASH?
DASH runs under Windows 10 and 11. To install it go to https://github.com/ccdc-opensource/dash/releases and download and run the latest release installer.
How should I reference DASH?
DASH: a program for Crystal Structure Determination from Powder Diffraction Data.
W. I. F. David, K Shankland, J. van de Streek, E. Pidcock, W. D. S. Motherwell, J. C. Cole. J. Appl. Cryst., 39, 910-915, 2006
DOI: 10.1107/S0021889806042117(http://dx.doi.org/10.1107/S0021889806042117)
Structure Solution and Refinement of Tetracaine Hydrochloride from X-ray Powder Diffraction Data.
H. Nowell, J. P. Atfield, J. C. Cole, P. J. Cox, K. Shankland, S. J. Maginn, W. D. S. Motherwell, New J. Chem., 26, 469-472, 2002
DOI: 10.1039/b109494g(http://dx.doi.org/10.1039/b109494g)
Structure Characterization of Three Crystalline Modificatins of Telmisartan by Single Crystal and High-resolution X-ray Powder Diffraction.
R. E. Dinnebier, P. Sieger, H. Nar, K. Shankland, W. I. F. David, J. Pharm. Sci., 89, 1465-1479, 2000
DOI: 10.1002/1520-6017(200011)89:11<1465::AID-JPS9>3.0.CO;2-C(http://dx.doi.org/10.1002/1520-6017(200011)89:11%3C1465::AID-JPS9%3E3.0.CO;2-C)
Routine Determination of Molecular Crystal Structures from Powder Diffraction Data.
W. I. F. David, K. Shankland, N. Shankland, Chem. Commun., 931-932, 1998
DOI: 10.1039/a800855h(http://dx.doi.org/10.1039/a800855h)
Indexing of Powder Diffraction Patterns for Low-symmetry Lattices by the Successive Dichotomy Method.
A. Boultif, D. Louër, J. Appl. Cryst., 24, 987-993, 1991
DOI: 10.1107/S0021889891006441(http://dx.doi.org/10.1107/S0021889891006441)
Is it possible to refine (preferably with constraints) the bond distances and angles of the molecule I am using?
Yes, it is possible to refine bond distances and angles during simulated annealing by manually editing the Z-matrix file (see the Z-matrix format Appendix for more details). Please note: DASH will also allow this during the additional Rietveld step.
Why am I having problems with the RIETAN-FP output format from DASH?
The format of the files used as input to RIETAN has changed quite significantly between RIETAN-2000 and RIETAN-FP. DASH currently recognises whether RIETAN-2000 or FP is being used based on the name of the RIETAN executable set in the configuration dialogue. In the RIETAN-Venus package, however, the executable for FP is no longer called rietan-fp.exe, but simply rietan.exe. In the future there will be a check-box available in the configuration dialogue to define whether RIETAN 2000 or FP is being used, but as a work-around it is possible to simply rename the executable to rietan-fp.exe and then DASH should output the correct format of files.
N.B. The interfaces to third-party refinement packages in DASH are kept as up-to-date as possible, but no support is provided by the CCDC for these external programs.
Are there any limits on the size of structure that DASH can solve?
There are no hard-coded limits on the size of molecule that DASH can handle. However, for large structures with many torsion angles (>15) structure solution will be difficult and good data are a necessity. There is a maximum of 1000 peaks that are allowed in the diffraction pattern.
DASH can handle multicomponent systems: salt, solvates, and other structures with more than one molecule in the asymmetric unit.
How many z-matrices can I input to the "Molecular Z-Matrices" window of DASH?
The number of Z-matrices which can be read in to DASH has been increased from 4 to 32, with up to 8 copies per Z-matrix. For counter-ions etc., multiple copies of the same Z-matrix should be used.
Which file formats are supported?
DASH supports the following Powder Diffraction File formats:
- .raw - Bruker
- .raw - STOE
- .rd and .sd - Philips
- .udf, .uxd and .xye
- .cpi - Sietronics
- .mdi - Materials Data Inc.
- .pod - Daresbury
- .x01 - Bede
- .txt - ThermoARL
- .asc - Rigaku