SmartLogger - bolliy/ioBroker.sun2000 GitHub Wiki
The Huawei SmartLogger is a data logger required for monitoring and managing Huawei inverters. It is also possible to connect several inverters in parallel in the same system and monitor them together.
The adapter saves the recorded data in the same way as when reading the inverter directly. In addition, some status values โโare stored in the path sun2000.0.slogger
sun2000 ioBroker Adapter connected smartlogger via Modbus TCP/IP
By default, the function for connecting to a third-party management system via Modbus TCP is deactivated on the smartlogger.
How to enable Modbus TCP on Smartlogger
-
Log in to WebUI of smartlogger: Choose
Settings/Modbus TCP
-
Link settings
: set this parameter to Enable (Unlimited) -
SmartLogger address
: Set this parameter to the communication address of the SmartLogger
How to configure the sun2000 Adapter
The setting is made via the configuration.
tab:Main settings
Integration
Huawei Device Integration
: Smart Logger (default: SDongle)
Device Settings
address
: Smart Logger IP addressport
: 502modbusIds
: inverter modbus IDs, separated with "," (max. 5 inverters)
tab: Integration
SmartLogger Settings
The Meter modbus ID
: modbus ID of Smart Power Sensor (usually: 11)
Links
Smartlogger connected with third-party via Modbus TCP/IP and Modbus RTU