The EMMA is a device that manages energy in a home with a PV system. It can implement unified scheduling and management of home energy.
The adapter saves the recorded data in the same way as when reading the inverter directly. In addition, some status values โโare stored in the path sun2000.0.emma
sun2000 ioBroker Adapter connected emma via Modbus TCP/IP
By default, the function for connecting to a third-party management system via Modbus TCP is deactivated on the emma.
How to enable Modbus TCP on Emma
-
Via the Fusion Solar app log in with installer access
-
Under
Services
>Commissioning the device
in theSettings
>Communication configuration
- Modbus TCP connection: Enable
- TLS: off
- client IP address: ioBroker ip Address
How to configure the sun2000 Adapter
The setting is made via the configuration.
tab: Main settings
Integration
Huawei Device Integration
: Select EMMA (default: SDongle)
Device Settings
address
: Emma IP addressport
: 502modbusIds
: inverter modbus IDs, separated with "," (max. 5 inverters)