NSCP 2015 load combination - albertp16/loadcombojs GitHub Wiki
Reference: National Structural Code of the Philippines (NSCP) 2015
Symbols and Notations
from Section 203.2
- D = Dead load
- E = Earthquake load
- F = load due fluids with well-defined pressures and maximum heights
- H = load due to lateral pressure of soil and water in soil.
- L = live load, except roof live load, including any permitted live load reduction
- Lr = roof live load
- P = ponding load
- R = rain load on the undeflected roof
- T = self-straining force
- W = load due to wind pressure
Load and Resistance Factor
from Section 203.3
- 1.4(D + F)
- 1.2(D + F + T) + 1.6(L + H) + 0.5(Lr or R)
- 1.2D + 1.6(Lr or R) + (f1*L or 0.5W)
- 1.2D + 1.0W + f1*L + 0.5(Lr or R)
- 1.2D + 1.0E + f1*L
- 0.9D + 1.0W + 1.6H
- 0.9D + 1.0E + 1.6H
where:
- f1 = 1.0, for floor in places of public assembly, for live loads in excess of 4.8kpa, and for garage live load, or
- f1 = 0.5, for other live loads.
Allowable Strength
from Section 203.4
- D + F
- D + H + F + L + T
- D + H + F + (Lr or R)
- D + H + F + 0.75[L + T + (Lr or R)]
- D + H + F + (0.6W or E/1.4)