NSCP 2015 load combination - albertp16/loadcombojs GitHub Wiki

Reference: National Structural Code of the Philippines (NSCP) 2015

Symbols and Notations

from Section 203.2

  • D = Dead load
  • E = Earthquake load
  • F = load due fluids with well-defined pressures and maximum heights
  • H = load due to lateral pressure of soil and water in soil.
  • L = live load, except roof live load, including any permitted live load reduction
  • Lr = roof live load
  • P = ponding load
  • R = rain load on the undeflected roof
  • T = self-straining force
  • W = load due to wind pressure

Load and Resistance Factor

from Section 203.3

  • 1.4(D + F)
  • 1.2(D + F + T) + 1.6(L + H) + 0.5(Lr or R)
  • 1.2D + 1.6(Lr or R) + (f1*L or 0.5W)
  • 1.2D + 1.0W + f1*L + 0.5(Lr or R)
  • 1.2D + 1.0E + f1*L
  • 0.9D + 1.0W + 1.6H
  • 0.9D + 1.0E + 1.6H

where:

  • f1 = 1.0, for floor in places of public assembly, for live loads in excess of 4.8kpa, and for garage live load, or
  • f1 = 0.5, for other live loads.

Allowable Strength

from Section 203.4

  • D + F
  • D + H + F + L + T
  • D + H + F + (Lr or R)
  • D + H + F + 0.75[L + T + (Lr or R)]
  • D + H + F + (0.6W or E/1.4)